1610.02. - Amendments.

The International Fire Code, adopted in Section 1610.01, is hereby amended as follows: I.F.C. Section 102.7 Referenced Codes and Standards is hereby amended by including the following language: The codes and standards referenced in this code shall be those that are listed in Chapter 80 and such codes and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. This code and standards referenced in this code shall be the most recently published edition or version. Where differences occur between the provisions of this code and the referenced standards, the provisions of this code shall apply. I.F.C. Section 111 Board of Appeals is hereby deleted and replaced with the following language: Appeals The Board of Appeals for appeals made under the Fire Prevention Code of the City of Lansing shall be the Building Board of Appeals established in Section 113 the Michigan Building Code adopted in Section 1420.01 of the Codified Ordinances of Lansing. The Board shall determine the suitability of alternative materials and the type of construction and provide reasonable interpretations of the provisions of this code. The Board shall render all decisions and findings in writing to the Fire Chief, with a duplicate copy to the appellant, and may recommend to the executive body such new legislation for engaging in the following activities, operations, practices or functions: (1) Fire suppression systems. To design, install, modify, test, service and maintain any and all fire suppression systems in accordance with any and all codes that apply to this installation. (2) Fire alarm systems. To design, install, modify, test, service and maintain any and all fire alarm systems in accordance with any and all codes that apply to this installation. (3) Open burning. To ignite or burn material of any type on private land or on publicly owned or controlled land, except as provided in this code. (4) Fireworks. To conduct a public display or to use for agricultural or pest control purposes as permitted by State law. I.F.C. Section 112.4 Violation Penalties is hereby deleted in its entirety. I.F.C. Section 113.4 Failure to Comply is added to read as follows: Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition shall be subject to the penalties codified in Section 1610.99 of this code. I.F.C. Section 503 Fire Apparatus Access Roads is hereby added as follows: (1) Authority. The Fire Department may establish fire apparatus access roads on both public and private property within the City. The following criteria shall be used in determining the necessity of fire apparatus access roads: (a) Fire apparatus access roads shall be established as deemed necessary. (b) The necessity of access from public thoroughfares shall be considered when establishing fire apparatus access roads. (c) The necessity of traffic lanes that are free from parked vehicles, both to and around affected establishments, and that are capable of handling City fire vehicles, shall also be considered. This determination shall be made whenever the Fire Department deems that such lanes are necessary for the safety of occupants and property of such establishments or when, after being petitioned by a private landowner to have fire apparatus access roads established on his or her property, the Fire Department declares fire apparatus access roads necessary thereon in accordance with the above criteria. The Fire Chief or his or her designee shall notify the landowner of any such property whereon fire apparatus access roads are established, by mailing notice of the same to the address of the owner as identified in the records of the City Assessor. (2) Records. The Fire Department shall keep an accurate up to date record of all fire apparatus access roads established within the City. (3) Signs. All fire apparatus access roads shall be conspicuously posted with uniform fire apparatus access road signs prescribed by the Fire Chief or his or her designee and erected not more than 100 feet apart in all areas designated as fire apparatus access roads. The erection and maintenance of such signs shall be the responsibility of the property owner. Any owner who, upon notification that a fire apparatus access road has been established on his or her property and within 30 days thereof, fails to erect uniform fire apparatus access road signs, shall be in violation of this section and subject to the penalty provided in Section 1610.99 of the Codified Ordinances of the City. Further, when such signs are not erected within 30 days of notification, Council may direct such signs to be erected, and the cost thereof assessed against the property on the next general assessment roll of the City. (4) Permitted parking. The Fire Chief or his or her designee may grant permission for parking of certain vehicles, objects or trailers in designated fire apparatus access roads for limited periods where such parking will not interfere with the use of the fire apparatus access road by emergency vehicles. Whenever such permission is granted, a record of the same shall be kept by the Fire Department. In conjunction with such permission, the Fire Department shall furnish a sign to be posted conspicuously on the vehicle, object or trailer stating that permission to so park has been granted and stating the duration that it may remain so parked. (5) Guidelines for fire apparatus access roads at construction sites. The Fire Chief or his or her designee shall establish guidelines for use by the Building Safety Division in determining the need for fire apparatus access roads at all new construction sites and at sites where existing structures are being modified. These guidelines shall include minimum dimensions for such fire apparatus access roads so as to provide adequate maneuverability for City fire vehicles. The Fire Department shall make a final check of all plans for such building or alteration upon submission of the same by the Building Safety Division. The Fire Department shall either approve or reject such plans within 20 days of such submission and, if rejected, shall state the reasons for the same. After rejection, such plans may be resubmitted for approval after the necessary changes have been made. (6) Removal of vehicles, etc., from fire apparatus access roads. When any member of the Fire department or the Police Department observes any vehicle, trailer or other object parked in a fire apparatus access road as herein established, and such vehicle, trailer or other object is not in such fire apparatus access road under authority of Subsection (4) hereof, he or she shall remove such vehicle, trailer or other object or cause the same to be removed at the expense of the owner. If any vehicle, trailer or other object is so located within a fire apparatus access road at a time the Fire Department is responding to an alarm which necessitates use of such fire apparatus access road, then any member of the Police Department or the Fire Department may move such vehicle, trailer or other object or cause the same to be moved by any means possible without liability for damage. (7) Prohibited parking; citations. (a) No person shall stop, stand or park a vehicle, except when necessary to avoid conflict with other traffic or in compliance with the directions of a law enforcement officer, fire-fighter or traffic control device, within 15 feet of a fire hydrant. (b) No person shall stop, stand or park a vehicle, whether occupied or not, in an area designated as a fire apparatus access road, on public or private property, except when necessary to avoid conflict with other traffic or at the direction of a law enforcement officer, fire-fighter or traffic control device. (c) The Fire Marshal and other members of the Fire Department shall have the power and authority to issue uniform traffic citations for a violation of any of the provisions of this section pursuant to Section 257.675d of the Michigan Motor Vehicle Code. (8) Appeals. Notwithstanding the provisions of Section 111 of this code, the following shall be the method of appeal from any decision of the Building Board of Appeals as it may pertain to this section: If any land owner is aggrieved by any decision as to the establishment of fire apparatus access roads, he or she shall, within 30 days of the date of mailing of the fire apparatus access road establishment notice as provided for in Subsection (c) hereof, or within 30 days of the denial of a petition to establish a fire apparatus access road, file with the Board of Appeals a written exception to such decision, together with his or her reasons for the same. During the next scheduled meeting of the Board of Appeals, or a special meeting set for hearing the exception, it shall, after consideration of the reasons for the exception, affirm, modify or rescind its original decision. I.F.C. Section 605.8 Incinerators is hereby deleted and a new Section 605.8 is added as follows: Incinerators (1) General. Free-standing noncommercial incinerators not connected to buildings are not permitted. Permitted incinerators shall be in accordance with other governing agencies' requirements regulating emissions. For other requirements, see the Michigan Building Code, as adopted in Section 1420.01 of the Codified Ordinances of the City of Lansing, and the Michigan Mechanical Code, as adopted in Section 1426.01 of the Codified Ordinances of Lansing. (2) Maintenance. Incinerators shall be maintained in good condition at all times. (3) Discontinuance. The Fire Chief and his or her designee authorized to require incinerator use to be immediately discontinued if the Fire Chief or his or her designee determines that smoke emissions are offensive to the occupants of surrounding property or if the use of the incinerator is determined by the Chief or his or her designee to constitute a hazardous condition. I.F.C. Section 907.2.13 High Rise buildings is hereby amended to include the following: This section shall include the adopted State of Michigan Bureau of Construction Codes Amendments to the International Building Code. I.F.C. Section 905.12 Existing Buildings is hereby deleted in its entirety. I.F.C. Section 5504.3.1.1.3 Location is hereby deleted and a new Section 5504.3.1.1.3 is added as follows: Stationary containers shall be located in accordance with section 5504.3.1.1.3 Containers of cryogenic fluids shall not be located within diked areas containing other hazardous materials. The geographic limits in which the storage of flammable cryogenic fluids in stationary containers is prohibited are to be determined by the Fire Chief or his or her designee in accordance with NFPA 30 Flammable and Combustible Liquids Code, Michigan Department of Environment, Great Lakes, and Energy (EGLE), Sections 5504.3.1.1—5504.3.1.1.5, Table 5504.3.1.1, and any other applicable code or standard recognized by the Fire Chief or his or her designee. I.F.C. Section 5704.2.9.6.1 Locations Where Above-ground Tanks are Prohibited is hereby deleted and a new Section 5704.2.9.6.1 is added as follows: The geographic limits in which the storage of class I and class II liquids in above-ground tanks outside of buildings is prohibited is to be determined by the Fire Chief or his or her designee in accordance with NFPA 30 Flammable and Combustible Liquids Code, Department of Environmental Quality, and any other applicable code or standard recognized by the Fire Chief or his or her designee. I.F.C. Section 5706.2.4.4 Locations Where Above-ground Tanks are Prohibited is hereby deleted and a new Section 5706.2.4.4 is added as follows: The geographic limits in which the storage of class I and class II liquids in above-ground tanks is prohibited are to be determined by the Fire Chief or his or her designee in accordance with NFPA 30 Flammable and Combustible Liquids Code, Department of Environmental Quality, and any other applicable code or standard recognized by the Fire Chief or his or her designee. I.F.C. Section 6104.2 Maximum Capacity Within Established Limits is hereby deleted and a new Section 6104.2 is added as follows: The geographic limits in which the storage of liquefied petroleum gas is restricted for the protection of heavily populated or congested areas is to be determined by the Fire Chief or his or her designee in accordance with NFPA 58, the Liquefied Petroleum Gas Code, the Michigan Mechanical Code, and any other applicable code or standard recognized by the Fire Chief or his or her designee. The aggregate capacity of any one installation shall not exceed a water capacity of 2,000 gallons (7,570 liters). Exception: In particular installations, this capacity limit shall be determined by the Fire Chief or his or her designee, after consideration of special features such as topographical conditions, nature of occupancy, and proximity to buildings, capacity of proposed containers, degree of fire protection to be provided and capabilities of the local fire department.

(Ord. No. 1171, § 1, 8-8-11; Ord. No. 1177, § 1, 1-30-12; Ord. No. 1288, § 1, 6-21-21; Ord. No. 1340, § 1, 8-25-25)

Ask a question about Lansing law

Corpus searches the Lansing sections it holds and shows the ones that match, with their citations. Free, no sign-in.