§ 122-152 — Preparation for tentative approval
Code of Ordinances of the City of Rochester Hills, Michigan (Codified through Ordinance No. 203, enacted August 24, 2026 (Supp. No. 54)) · Rochester Hills Land Development Regulations § 122-152
Corpus is an independent public-information project, not the official City of Rochester Hills website. Stable reference: corpuslaw.us/code/f6728e40-8734-4398-805e-4561d95d38f1
Sec. 122-152. - Preparation for tentative approval.
The subdivision preliminary plat shall be prepared in accordance with sections 111 and 112 of the Land Division Act, Public Act No. 288 of 1967 (MCL 560.111, 560.112, MSA 26.430(111), 26.430(112)), and in accordance with the requirements of this section. The following information shall be shown on the preliminary plat or submitted with it: (1) Identification and description. a. Proposed name of the subdivision. b. A complete legal description. c. Names and addresses of the proprietor, owner and planner, landscape architect, designer, engineer or surveyor who designed the subdivision layout. The proprietor shall also indicate his interest in the land. d. Date, north point and scale of the plat with one inch equals 100 feet as the minimum acceptable scale. (2) Existing subdivision site conditions. Existing subdivision site conditions as follows: a. Site area map. An overall map at a scale of one inch equals 2,000 feet showing the relationship of the subdivision to its surroundings such as section lines and/or major streets or collector streets shall be provided and shall include the following: 1. Boundary lines of the proposed subdivision, section or city lines within or adjacent to the tract and overall property dimensions. 2. Property lines and zoning of contiguous tracts of subdivided and unsubdivided land up to one-half mile are to be shown in relation to the tract being proposed for subdivision including those located across abutting roads. 3. Location, widths, and names of existing or prior platted streets and private streets, public areas, sidewalks, and public easements within or adjacent to the tract being proposed for subdivision, including those located across abutting roads. 4. Location of existing sewers, water mains, storm drains and other underground facilities, within or adjacent to the tract being proposed for subdivision. b. Drainage pattern sketch. Drainage patterns shall be graphically displayed on an accompanying sketch and shall include the following information: 1. River, stream, or open (ditch) drainageways and the direction of their flow. 2. The direction of surface drainage over the site. 3. Ridge lines or watershed boundaries, if any, on or within one-half mile of the site. 4. Soil drainage characteristics as follows: i. Well drained. ii. Subject to ponding. iii. Susceptible to flooding. c. Topography and slope gradient sketch. Topography drawn to contours with an interval of at least two feet in elevation. Topography shall be based on United States Geological Survey Datum. Benchmarks for the work shall be indicated on the drawing. If slope gradients of two percent or greater exist on the site, a sketch shall be presented with shadings for the first two to four percent change, the four to ten percent change, the ten to 20 percent change and the 20 percent and greater change. The topographic map and slope gradient sketch shall include the area of the proposed subdivision as well as an area at least 200 feet beyond it. d. Soil sketch. Soil types and characteristics as made available by the United States Department of Agriculture Soil Conservation Service shall be sketched and submitted at the same scale as the subdivision site indicating the suitability of the proposed site for the proposed development. e. Site vegetation map. Vegetation on the site shall be inventoried in a general manner and sketched in a general way as to type and location on a map at the same scale as the preliminary plat. In particular, existing trees of six inches in caliper or greater by type and size shall be recorded as well as the ground elevation at the base of each tree of significant size, or clusters of trees at the same general base elevation. (3) Preliminary plat drawing. A refined illustration showing the following information shall be submitted as the preliminary plat drawing: a. Layout of streets indicating proposed street names, right-of-way widths and connections with adjoining platted streets and also the widths and location of alleys, existing easements, and, if the plat is for the development of a single-family residential subdivision, sidewalks. b. Layout, number and dimensions of lots, including building setback lines showing dimensions. c. Indication of parcels of land intended to be dedicated or set aside for public use and/or for the use of property owners in the subdivision. d. An indication of the status of the petitioner's ownership, and existing and proposed use of any parcels identified as "excepted" on the preliminary plat. If the proprietor has an interest or owns any parcel so identified as "excepted," the preliminary plat shall indicate how this property could be developed in accordance with the requirements of the existing zoning district in which it is located and with an acceptable relationship to the layout of the proposed preliminary plat. e. Statement of intended use of the proposed plat such as residential single-family, two-family, and multiple housing; commercial; industrial; recreational; or agriculture. Also proposed sites, if any, for multifamily dwellings, shopping centers, churches, industry, and other nonpublic uses exclusive of single-family dwellings. Also, for any site proposed for parks, open space or common area, playgrounds, schools, or other such uses, there shall be a separate plan indicating how the area will be developed and utilized including specific details for active and/or passive recreational activities. f. If the subdivision is proposed to be developed under the open space provisions of the zoning ordinance, subdivision shall meet the requirements of division 4 of this article and the appropriate sections of the zoning ordinance. g. A general indication of all proposed underground utilities which shall include, but not by way of limitation, the water and sanitary sewer system, storm sewers, and electrical and gas lines, fire hydrants, and water retention basins. (4) Design concept sketch. A design concept sketch at one inch equals 100 feet shall be submitted with the plat that shows the features proposed for development (i.e., lots, streets, sidewalks, drains, open space, parks, schools, etc.,) related to the site's natural characteristics (drainage, topography, slope, soil types, vegetation, trees, etc.). The reason this scheme was chosen over others shall be noted. (5) Environmental impact statement. An environmental impact statement as required by the zoning ordinance.
(Code 1976, § 4-01.05.01)
Ask a question about Rochester Hills law
Corpus searches the Rochester Hills sections it holds and shows the ones that match, with their citations. Free, no sign-in.
