For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 138-10.202 — General Provisions

Code of Ordinances of the City of Rochester Hills, Michigan (Codified through Ordinance No. 203, enacted August 24, 2026 (Supp. No. 54)) · Rochester Hills Land Development Regulations § 138-10.202

Corpus is an independent public-information project, not the official City of Rochester Hills website. Stable reference: corpuslaw.us/code/dcd6c0d3-db72-4380-9504-20f8ecf64740

SECTION 138-10.202 - General Provisions

The design and illumination standards of this chapter shall apply to all exterior lighting sources and other light sources visible from the public right-of-way, road easement or adjacent parcels, except where specifically exempted herein. [image omitted; see the official code] Figure 5. Lighting Fixture Orientation and Shielding A. Shielding. Exterior lighting shall be fully shielded and directed downward at a 90 degree angle. Oblique lenses (such as many wall-pack fixtures) are prohibited. All fixtures shall incorporate full cutoff housings, louvers, glare shields, optics, reflectors or other measures to prevent off-site glare and minimize light pollution. Only flat lenses are permitted on light fixtures; sag or protruding lenses are prohibited. B. Glare. Exterior lighting sources in all districts shall be designed, constructed, located and maintained in a manner that does not cause off-site glare on neighboring properties or street rights-of-way. Except as otherwise permitted, the light emitting element of any light fixture shall not be directly visible from a neighboring property, as this is the primary cause of glare. The light emitting element of any light fixture that exceeds 400 lumens shall be fully shielded. C. Light trespass. Light levels shall not exceed 0.1 footcandles at the property line where the site abuts a public right-of-way or a lot with a residential use or zoning. Where the site abuts a non-residential use, light levels at the property line shall not exceed 0.3 footcandles. D. Lamps. All fixtures shall comply with Illuminating Engineering Society of North America standards. E. Required illumination. Lighting should be even throughout and shall not exceed an average illumination to minimum illumination ratio of 4:1. Specific areas on a site shall be illuminated in accordance with the following table: Site/Building Feature | Minimum Footcandles | Maximum Footcandles Pedestrian areas/sidewalks | 0.2 | 1.0 Building entrances | 1.0 | 5.0 Driveway lighting | 0.2 | 1.0 Parking areas | 0.2 | 2.0 Parking areas or maneuvering lanes within 25 feet of the building | 2.0 | 4.0 Under gas station canopies, outdoor sales areas, immediate vicinity of an ATM, loading docks | 3.0 | 20 F. Hours of operation. All exterior lighting in non-residential districts shall incorporate automatic timers and shall be turned off between the hours of midnight and sunrise, except for lighting necessary for security purposes or accessory to a use that continues after midnight. Security lighting shall, to the extent practical, uses sensors and dim or turn off when there is no activity on site. G. Measurement. Light intensity shall be measured in footcandles on the horizontal plane at grade level within the site and on the vertical plane at the property or street right-of-way boundaries of the site at a height of five feet above grade level. H. Lighting height. Fixture height shall be measured from the grade of the illuminated surface directly below the fixture to the bottom of the fixture. I. LED light sources shall have a correlated color temperature that does not exceed 3,000K.

(Ord. No. 190, § 7, 4-25-2022)

Ask a question about Rochester Hills law

Corpus searches the Rochester Hills sections it holds and shows the ones that match, with their citations. Free, no sign-in.