§ 138-6.104 — Design Standards
Code of Ordinances of the City of Rochester Hills, Michigan (Codified through Ordinance No. 203, enacted August 24, 2026 (Supp. No. 54)) · Rochester Hills Land Development Regulations § 138-6.104
Corpus is an independent public-information project, not the official City of Rochester Hills website. Stable reference: corpuslaw.us/code/0dd2fafb-b522-4505-9b9e-c169855926dd
SECTION 138-6.104 - Design Standards
A. Building Height. The maximum building height for any structure in an RM-1 district shall be 2.5 stories and 30 feet. B. Architectural details. Walls visible from a street or other residential uses shall include windows and architectural features similar to the front facade of the building, including, but not limited to awnings, cornice work, edge detailing or other decorative finish materials. All buildings shall have pitched roofs, which may include functional dormer windows and varying lines customary with gable or hip style roofing. Standing seam metal roofing is prohibited. C. Garage Orientation. Where attached unit buildings contain attached or detached garages that are accessory to the dwelling unit, no more than 25 percent of all garage doors may be located at or in front of the front building wall of the building, with all other garage doors being located at least ten feet behind the front building wall of the unit or facing the side or rear of the unit. There is no limitation on the number or orientation of parking areas, garages and any other accessory structure or uses that may be located within the established rear yard, with access provided by an alley or access drive. [D.] Front Door Orientation. For attached dwelling types that have individual entrances directly to the exterior of the building (such as townhouse and stacked flat buildings), a minimum of 75 percent of the main entrances to the individual dwellings shall be located on the front façade of the building, and all shall include a front porch or stoop that is at least six feet in width and depth with a minimum area of 36 square feet. The front porch or stoop may encroach into the front yard setback area provided that it remains unenclosed. [E. ]Street design and vehicular circulation. Street connections shall be provided to adjacent neighborhoods and parcels in residential districts. Ingress and egress from the public streets shall be designed to minimize congestion and interference with normal traffic flow. All interior roads, drives, and parking areas within a multi-family development shall be hard surfaced and provided with curbs and gutters. Roadway drainage shall be appropriately designed such that stormwater from the roadway will not drain onto the adjacent lots. [F.] Pedestrian circulation. Minimum five-foot wide concrete sidewalks shall be provided to connect parking areas, public sidewalks and recreation areas to all building entrances. Minimum six-foot wide concrete sidewalks shall be provided along collector roads and streets within the development. Sidewalks or minimum eight-foot wide asphalt pathways shall be provided along streets adjacent to the development in accordance with adopted City plans and policies. [G.] Parking. 1. On-street parking on interior streets shall count towards the minimum parking requirement. Where on-street parking is permitted, the street shall have a minimum clear circulation lane of 16 feet and parking stalls shall have a minimum width of eight feet and a minimum length of 22 feet. 2. All off-street parking spaces must be screened from view of any public road, pedestrian path, or adjacent single-family residential dwelling unit in compliance with Section 138-12.205.B. (Landscape Requirements). 3. Off-street parking lots may occupy up to 50 percent of a required front yard and 75 percent of a required rear yard, provided that no portion of the parking lot is located closer than 15 feet to a perimeter property line. [H.] Recreation areas. Passive or active recreation areas (including but not limited to seating areas, playgrounds, swimming pools, walking paths and other recreational elements in accordance with the intended character of the development) shall be provided at a ratio of at least five percent of the gross area of the development. The minimum size of each area shall be not less than 5,000 square feet, and the length to width ratio of each area, as measured along the perimeter, shall not exceed four to one (4:1). Such areas shall be centrally and conveniently located to be physically and visibly accessible to residents, and shall not be located within any required yard setbacks or building separations. [I.] Utilities. All multiple-family dwellings shall be connected to the public sewer and public water system.
Ask a question about Rochester Hills law
Corpus searches the Rochester Hills sections it holds and shows the ones that match, with their citations. Free, no sign-in.