§ 138-6.702 — Building Frontages
Code of Ordinances of the City of Rochester Hills, Michigan (Codified through Ordinance No. 203, enacted August 24, 2026 (Supp. No. 54)) · Rochester Hills Land Development Regulations § 138-6.702
Corpus is an independent public-information project, not the official City of Rochester Hills website. Stable reference: corpuslaw.us/code/ddb1f53f-d4b6-4afb-b80e-8a9c492c45ed
SECTION 138-6.702 - Building Frontages
The purpose of this section is to identify the frontage types allowed in the R-5 District, and for each type, provide a description, a statement as to the type's intent and design standards, to ensure that proposed development is consistent with the city's goals for walkability and residential character by providing proper building form, character, and quality. [image omitted; see the official code] A. Projecting Porches. (1) Description. The main facade of the building typically has a small-to-medium setback from the property line. The resulting front yard is typically small and may or may not be defined by a fence or hedge to separate the edge of the street right-of-way and private property. (2) Standards. The projecting porch shall be open on three sides and shall have a roof form that is separate from the main house. The porch may extend one or two stories. The minimum width is 10 feet, the minimum depth is 8 feet, and a minimum clearance of 8 feet is required from the floor to the lowest point of the roof structure. The porch should be elevated above the private sidewalk that connects the porch to the public sidewalk running along the lot frontage. B. Integral Porch. [image omitted; see the official code] (1) Description. The main facade of the building has a small setback from the property line. The resulting front yard is typically small and may be defined by a fence or hedge to spatially maintain the edge of the street. An integral porch is part of the overall massing and roof form of a building. With an integral porch it is not possible to remove the porch without major changes to the overall roof form. [image omitted; see the official code] (2) Standards. The integral porch shall be open on two or three sides and has a roof form that is part of the roof structure of the main building. The porch may extend one or two stories. The minimum width is 8 feet, the minimum depth is 8 feet, and a minimum clearance of 8 feet is required from the floor to the lowest point of the roof structure. The porch should be elevated above the private sidewalk that connects the porch to the public sidewalk running along the lot frontage. C. Stoop. [image omitted; see the official code] (1) Description. The main facade of the building is near the property line and the elevated stoop engages the sidewalk. The stoop may or may not have a roof form. (2) Standards. The stoop should be elevated above the sidewalk to ensure privacy within the building. Stairs from the stoop may lead directly to the sidewalk or may be accessed from the side. The minimum width is 5 feet and the maximum is 10 feet; the minimum depth is 5 feet and the maximum is 10 feet; and a minimum clearance of 8 feet is required from the floor to the lowest point of the roof structure, when provided. D. Forecourt. (1) Description. A portion of the main facade of the building is at or near the property line and a small percentage is set back, creating a small court space. The space could be used as an entry court or shared garden space for multiplex. The proportions and orientation of these spaces should be carefully considered for solar orientation and user comfort. [image omitted; see the official code] (2) Standards. A forecourt shall be a minimum of 12 feet wide and 12 feet deep. A 30-inch to 36-inch high edge wall shall define the edge of the courtyard. The edge wall shall be located within 5 feet of the front lot line and shall be constructed of 1) brick or stone or 2) brick or stone piers, at least 24 inches wide and no more than 15 feet apart, connected by a black metal decorative fence of the same height, with supplemental shrub or ornamental grass plantings. All walls and piers shall have a suitable stone cap. This frontage type should be used sparingly along a block frontage. E. Flex Dooryard. [image omitted; see the official code] (1) Description. The facade of the building that faces the front street is setback a small distance from the street, typically within a build-to-zone. The front property line is oftentimes defined by a low wall, fence, or hedge, creating a small dooryard. The dooryard shall not provide public circulation along the rights-of-way. The dooryard is most often intended for ground floor residential but can also be used for allowed nonresidential uses. The façade of the building that contains the main entry fronts on a greenspace area that may be a street-facing yard, as described above, or it may front on an internal greenspace or pedestrian plaza. (2) Standards. A dooryard shall be constructed for access at grade or it may be raised. There shall be a sidewalk connecting the flex dooryard entryway to an internal sidewalk. The internal sidewalk shall connect to a public sidewalk or internal private sidewalk system.
(Ord. No. 186, pt. 11, 12-2-2019)
Ask a question about Rochester Hills law
Corpus searches the Rochester Hills sections it holds and shows the ones that match, with their citations. Free, no sign-in.