Sec. 98-363. - Wiring grouping and protection.

(a) Under this article, wiring shall, when possible, be grouped together and protected by nonmetallic tape, braid, or other covering capable of withstanding severe abrasion or shall be protected by being enclosed in a metallic sheath or tube. (b) Wiring shall be properly supported. (c) Wiring shall not be so located as to be likely to be charred, overheated, or enmeshed in moving parts. (d) Insofar as is practicable, wiring shall not be adjacent to any part of the fuel system. (e) The edges of all holes in metal through which the wiring passes, unless the wiring is metal covered, shall be rolled or bushed with a grommet of rubber or other suitable material.

(Code 1976, § 7-16.05.13)