For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 14C.05 — BUILDING/SITE DESIGN

Code of Ordinances of the City of Sterling Heights, Michigan (2026 S-46: Local legislation current through Ord. 509, passed 5-19-26) · Sterling Heights Zoning Ordinance § 14C.05

Corpus is an independent public-information project, not the official City of Sterling Heights website. Stable reference: corpuslaw.us/code/07d0a690-8860-460d-b175-916b5656121a

SECTION 14C.05. BUILDING/SITE DESIGN.

All development in the District is required to comply with these Building/Site Design Standards. The tables following each subsection include the specific dimension for each requirement, and supplements the descriptions included in this section. A. Facade Composition. 1. Materials. a. All new buildings constructed after the effective date of this article and all lawfully existing buildings prior thereto that have been altered over 50% on the exterior facade shall comply with the material requirements detailed below. i. The exterior of all buildings shall be constructed of aesthetically pleasing brick and/or stone building materials or other similar durable decorative building materials approved by the Office of Planning. Vinyl material is strictly prohibited. ii. Metal, stucco, and other materials as approved by the Office of Planning may be used for accents on the facade. iii. A minimum amount of the wall area of any ground floor on a street facing facade shall consist of durable materials according to Table 14C.05.A.4, Facade Material and Transparency Requirements. Windows and doors shall not be included in this calculation. iv. Floors above the ground floor level shall include the minimum percentage of durable materials on any street facing facade defined in Table 14C.05.A.4, Facade Material and Transparency Requirements. 2. Transparency. a. The following standards shall apply to all public street facing facade of any building constructed after the effective date of this article and all lawfully approved additions to public street facing facade of buildings in existence prior to the effective date of this article. i. The ground floor shall have a minimum amount percentage of glass, as calculated between 3 feet and 8 feet above grade in accordance with Table 14C.05.A.4, Facade Material and Transparency Requirements. When the ground level of the building consists of public street-facing residential uses, the specified requirement may be reduced by no greater than 15% by the Office of Planning. ii. For all upper floors of any multi-story building, all public street facing facade shall have a minimum percentage of glass in accordance with Table 14C.05.A.4, Facade Material and Transparency Requirements. iii. The Office of Planning may waive, decrease, and/or modify the transparency requirements required herein if the Office of Planning determines that the requirement would negatively affect the historic character or structural stability of an existing building. [image omitted; see the official code] Figure 14C.05.A.1-2: Durable Material and Transparency 1 The percentage of minimum durable material is provided in Table 14C.05.A.1. 2 The ground floor minimum transparency standard referenced in 14C.05.A.2.a.1. 3 The upper floor minimum transparency standard referenced in 14C.05.A.2.a.2. Table 14C.05.A.1-2 Facade Materials and Transparency Requirements Standard | District Core | Parkside | Utica Triangle | North Van Dyke Industrial Minimum Durable Materials - Ground Floor Materials (14C.05.A.1.a.iii) Note windows and doors should not be included in calculation. | 40% | 40% | 40% | 35% Minimum Durable Materials - Upper Floor (14C.05.A.1.a.iv) Note windows and doors should not be included in calculation. | 30% | 30% | 30% | 25% Minimum Transparency - Ground Floor (14C.05.A.2.a.i) | 60% | 60% | 60% | 50% Minimum Transparency - Upper Floor (14C.05.A.2.a.ii) | 55% | 55% | 55% | 40% B. Lot Coverage. 1. Lot coverage means the portion of a site that is covered by principal and accessory buildings and structures, as measured from the outside of the building or structure at ground level and expressed as a percentage of the total site area. In addition to all buildings, the lot coverage calculation shall include parking lots, accessory buildings, and any impervious surfaces including hardscaping. 2. The maximum lot coverage is provided in Table 14C.05.B, Lot Coverage and Lot Area Requirements. 3. The minimum lot coverage is provided in Table 14C.05.B, Lot Coverage and Lot Area Requirements. 4. Should a development be unable to reach the required minimum lot coverage provided in Table 14C.05.B, the Office of Planning may grant a modification as provided for in this article, or one or more of the following options may be used in lieu thereof: a. A privately owned, publicly accessible amenity space on the property. This space shall be a minimum of 500 square feet and include enough trees to provide a shade canopy that covers at least 60% of the area in order to satisfy this requirement. b. The building exceeds the transparency percentage required in Table 14C.05.A.1-2, Facade Materials and Transparency Requirements by 10%. c. The development utilizes at least two components of green infrastructure in excess of what is required in Section 24.12, Enhanced Landscaping Features, including, but not limited to, rain gardens, bioretention cells, vegetated swale, planter boxes, disconnected downspouts, green pavers, green roofs, or rain harvesting techniques. d. The development provides public amenities described in 14C.05.D.1, Pedestrian Amenities. Table 14C.05.B Lot Coverage and Lot Area Requirements Standard | District Core | Parkside | Utica Triangle | North Van Dyke Industrial Table 14C.05.B Lot Coverage and Lot Area Requirements Standard | District Core | Parkside | Utica Triangle | North Van Dyke Industrial Maximum Lot Coverage (14C.05.B.2) | 95% | 90% | 90% | 90% Minimum Lot Coverage (14C.05.B.3) Gross Lot Area: 0 - 4,999 | 55% | 50% | 50% | 45% Gross Lot Area: 5,000 - 9,999 | 50% | 45% | 45% | 40% Gross Lot Area: 10,000 - 19,999 | 45% | 40% | 40% | 35% Gross Lot Area: 20,000 - 24,999 | 40% | 35% | 35% | 30% Gross Lot Area: 25,000+ | 35% | 30% | 30% | 35% C. Building Massing. 1. All buildings with three or more stories shall be designed with varied massing to prevent flat, static streetscapes. Development must clearly articulate a horizontal hierarchy (base, middle, top) that is properly scaled to the height of the structure. Horizontal articulation shall be achieved through one or more of the following architectural features: a. Bay windows: Bay windows shall be a minimum of two feet in depth and four feet in width; b. Recessed entrances or windows: These shall be recessed a minimum of four feet in depth and six feet in width. Canopies or awnings are required at primary building entries; c. Niches: Niches shall be a minimum of two feet in depth and four feet in width; d. Gateways: Gateways shall be a minimum of four feet in width; e. Porches: Porches shall measure at least 48 square feet; or f. Colonnades: Colonnades shall be a minimum of four feet in width. [image omitted; see the official code] Figure 14C.05.C.1: Building Articulation 1 Recessed windows shall be recessed a minimum of 4 feet in depth and 6 feet in width 2 Recessed entrances shall be recessed a minimum of 4 feet in depth and 6 feet in width. 3 Porches must measure at least 48 square feet. 4 Bay windows shall be a minimum of 2 feet in depth and 4 feet in width. 5 Major facade articulations (pushes and pulls in depth) must occur at intervals no greater than approximately 25 feet. 2. Major facade articulations (pushes and pulls in depth) must occur at intervals no greater than 25 feet. 3. Roof types should be appropriate to the building's architecture. Roof line offsets or other architectural features shall be provided for architectural interest and variety to the massing of a building and to relieve the effect of a single long roof. Asphalt shingles, standing metal seamed material or other compatible materials shall be required on pitched roofs. Other roof materials, as determined by the Building Official, may be appropriate on flat roofs that are not visible to the public. a. Architectural detailing such as bays, balconies, decks, and roof trellises are encouraged to create design diversity and more complex geometries. b. Green roofs, solar roofs, and white-colored roofs are encouraged, where possible. 4. Upper floor stepbacks are required for all buildings that exceed the allowed maximum height. Refer to Table 14C.04.A.1, Subdistrict Dimensional Requirements, for the subdistrict's permitted height. a. The stepback, determined in Table 14C.05.C.5, Building Massing Requirements shall apply to all floors above the ground floor in buildings that are four stories or more in height. b. When the building is taller than five stories, all floors above the five shall step back by at least an additional 50% of the stepback identified in Table 14C.05.C.5, Building Massing Requirements. c. Balconies/patios and occupiable rooftops may be used to achieve this requirement. 5. Height Transitions. a. The height transition measurement is applied to control the size of tall buildings for such purposes as promoting transition in scale between buildings of different heights, protecting access to sunlight, and/or limiting shadow and overlook on neighboring properties. A height transition is required when there is a height difference of 30 feet or more between a proposed building and any adjacent zoning district with a lower building height limit or when buildings are taller than 60 feet. b. These developments are required to provide a stepback to allow for building separation and circulation of air and light. The stepback shall be a minimum width according to Table 14C.05.C.5 Building Massing Requirements. This stepback shall apply to all floors above the average height of the buildings on the block. [image omitted; see the official code] Figure 14C.05.C.5: Height Transition 1 The stepback is needed for height transition, which is required when there is a height difference of 30 feet or more between a proposed building and an adjacent zone district with a lower building height limit or when buildings are taller than 60 feet. The image stepback reference 14C.05.A.4.b. Table 14C.05.C.5 Building Massing Requirements Standard | District Core | Parkside | Utica Triangle | North Van Dyke Industrial Minimum Upper Floor Stepback (14C.05.C.4.a) | 10 feet | 10 feet | 10 feet | 10 feet Minimum Upper Floor Stepback Above 5 Floors (14C.05.C.4.b) | 15 feet | 15 feet | 15 feet | 15 feet Minimum Stepback for Height Transition (14C.05.C.5) | 15 feet | 10 feet | 10 feet | 10 feet D. Pedestrian Amenities. 1. Overhead covers are required at building entrances to provide weather protection to pedestrians and may encroach into a required yard, as indicated in this section, or into a public right of way with an approved encroachment agreement with the city. These coverings are required to be between nine and 14 feet above the level of the sidewalk and shall only contain the address of the property (all other signage is prohibited). The overhead covers shall also provide a minimum depth of coverage of six feet and project no closer than three feet to the curb. 2. All non-residential uses, including mixed-use developments, are permitted to provide street-side outdoor/cafe seating and dining patios, subject to the requirements of the city's Outdoor Patio Service licensing requirements and Section 28.19. This area shall be between the public right-of-way and the front facade along primary streets. In instances where there is sufficient sidewalk width for a minimum 6-foot clear path, the Office of Planning may grant a temporary use permit pursuant to Section 28.14 to allow temporary spill-out/seating areas within the public right-of-way, adjacent to development. 3. All developments shall have a minimum sidewalk width of eight feet, with landscaping that complies with subsection I, Landscape Standards, as set forth in this article. [image omitted; see the official code] Figure 14C.05.D.1: Pedestrian Amenity 1 Overhead covers are required at building entrances to provide weather protection and these coverings are required to be between 9 and 14 feet above the level of the sidewalk. They shall also provide a minimum depth of coverage of 6 feet and project no closer to the curb than 3 feet. 2 All non-residential developments are encouraged to provide street-side outdoor/cafe seating and dining patios. 3 All development shall have a minimum sidewalk width of 8 feet, with landscaping that complies with subsection I, Landscape Standards, as set forth in this article. E. Entrances. 1. A building entrance shall include a door and/or entry feature that provides visitors with direct access to the building and shall not open toward the street and/or public right-of-way. The street facing facade of all buildings shall have an operable entrance facing the street and a walkway to the nearest sidewalk. a. Additional operable building entrances shall be required, at a minimum, at each specified length of street facing building facade in accordance with the requirements set forth in Table 14C.05.E.1, Entrances Requirements. b. Buildings with parking lots in the rear shall have an operable building entrance for the public facing the parking lot. c. In addition to any applicable engineering standards, and except where in conflict with applicable engineering standards, curb cuts shall comply with the following: i. Curb cuts shall be 26 to 30 feet wide with a minimum 20-foot radius on each side. ii. The separation between two curb cuts shall be a minimum distance according to Table 14C.05.E.1, Entrances Requirements. iii. When major thoroughfares (Van Dyke Avenue and Utica Road) intersect with other secondary streets, curb cuts should be relocated to streets that are not considered major thoroughfares. This is intended to support fewer curb cuts on major thoroughfares. vi. Shared automobile entrances should be utilized. Table 14C.05.E.1 Entrances Requirements Standard | District Core | Parkside | Utica Triangle | North Van Dyke Industrial Minimum Distance of Pedestrian Entrances (14C.05.E.1.a) | 40 feet | 40 feet | 40 feet | 50 feet Minimum Curb Cut Distance (14C.05.E.1.b.ii) | 100 feet | 100 feet | 100 feet | 50 feet F. Parking Requirements. 1. All off-street parking shall comply with Article 23, Off-Street Parking and Loading Requirements expect as modified in this article. 2. In addition to the following standards, all parking lots must comply with the standards set in section 24.03. Parking Lot Landscaping Requirements. 3. All off-street parking shall be located behind street-facing facades. 4. The following standards are applicable to parking lots: a. All parking lots must contain a safe and accessible pedestrian connection as required pursuant to Section 24.10, Pedestrian Connections, unless modified herein. Additionally, these connections must comply with ADA accessibility standards, including, but not limited to: i. A connection route shall be at least three feet wide; ii. Pave sidewalks with smooth, durable material; iii. To the extent possible, have a maximum cross-slope of 1 inch of fall for every 4 feet of width (2% grade); iv. Limit longitudinal grades to 5%. A maximum of 8% may be used if necessary. When grades exceed 5%, special textures and handrails may be required as determined by the Office of Planning; v. Storm drain inlets are prohibited in the crosswalk; and vi. If a parking lot is approved to be adjacent to a public street and is within 50 feet of a public right-of-way, it shall be screened with native plantings, decorative fencing, decorative masonry, or a combination of these techniques, to a height of 34 inches. b. A landscaped island protected by a raised curb shall be established for every ten parking spaces. Islands shall be planted with a minimum of 1.5 canopy trees per island and at least three canopy trees per 100 feet of linear length, with the preferred planting material mix to include shrubs and native plants. Islands shall be located to organize and direct traffic flow within the parking lot and may be clustered. Except as modified herein, landscaping must comply with the requirements of Section 24.03, Parking Lot Landscaping Requirements. c. A parking lot shall not consist of more than two double-loaded parking aisles (bays) adjacent to each other. The length of a parking lot shall not exceed ten stalls. [image omitted; see the official code] Figure 14C.05.F.3-4: Parking Space 1 All off-street parking shall be located behind street-facing facades. 2 All parking lots must contain a safe pedestrian connection. 5. The following standards are applicable only to parking structures that are located adjacent to the street: a. A screening mechanism-either architectural, vegetation, or a combination-shall be provided. b. The structure shall comply with section 23.04, Parking Structure Development Standards. Compatibility with principal buildings may be achieved through building form and materials; the pattern, size, shape; and surface treatments such as cornices, moldings, reveals and sills. c. When associated with multi-family development, developers shall explore options that "wrap" housing around the parking garage. d. Parking garage entries shall be located off side streets or alleys, when applicable. 6. Shared Parking: a. Mixed-use districts benefit greatly from the differing parking demand levels at different times of the day. Shared parking is an arrangement that takes advantage of different peak parking demands through using the same off-street parking spaces to meet off-street parking requirements. The Office of Planning may permit shared parking if the following conditions are met: i. All developments, sites, and uses involved in the shared parking must be located within 1,320 feet (a quarter of a mile) from the shared parking, measured from the closest entrance of the use to the nearest parking space within the shared parking lot. ii. The site or sites involved must contain two or more separate and distinct building activities or functions which, by their nature, can use shared parking without having an adverse impact on traffic circulation or without impairing the overall functioning of the site or sites. iii. Shared parking shall be set forth in a recordable instrument signed by the property owner and recorded against the affected property in the Macomb County Register of Deeds, describing the property affected by this agreement, identifying the number of required spaces that have been reduced, and acknowledging that the reduction may affect future uses of the overall site depending on the type and scope of uses proposed and the total number of spaces available. b. The Office of Planning may approve a reduction in the number of off-street parking spaces required when multiple commercial uses provide their off-street parking in the same parking lot, as follows: i. Up to a 20% reduction may be approved when four or more commercial uses are involved. ii. Up to a 15% reduction may be approved when three commercial uses are involved. iii. Up to a 10% reduction may be approved when two commercial uses are involved. [image omitted; see the official code] Figure 14C.05.F.6: Shared Parking 1 Mixed-use districts benefit greatly from the differing parking demand levels at different times of day. Shared parking is an arrangement that takes advantage of different peak parking demands through two or more buildings using the same off-street parking spaces to meet parking requirements. The diagram above uses the daytime office building and residential building as an example. [image omitted; see the official code] Figure 14C.05.F.6: Shared Parking G. Parks and Open Space Requirements. 1. A minimum percentage of open space is required for all developments pursuant to Section 14C.04.A.1, Subdistrict Regulations. In addition to the minimum percentage required, all land designated as open space shall comply with the following conditions: a. Developments shall provide public linkages from its own open space to adjacent open spaces to contribute to and connect the larger green network. b. Bifurcation of green space shall be minimized to the greatest extent possible. 2. Open space consists of one or more open usable areas, the purpose of which is to provide an outdoor area designed for outdoor living and recreation. Plazas, courtyards, and other pedestrian amenities, excluding retention and detention ponds, may count toward the open space required. To count toward the requirement, the open space must be accessible and include at least two of the following amenities: a. Native planting areas that are strategically created and contain elements of landscape design. b. Pedestrian scale bollards or other accent lighting. c. Special paving, such as colored/stained concrete, brick, or other paver type. d. Artwork. e. Bike racks. f. Seating, such as tables and chairs or low seating walls. g. Fountains or other similar prefabricated water features. h. Playgrounds, fields, plazas, or courts. i. Green rooftops. j. Rooftop terraces. k. Community gardens. 3. Preserve Existing Trees. a. All developments shall comply with Chapter 51, Article III - Tree Preservation. H. Screening Requirements. 1. All screening shall be in accordance with Section 24.01 - Screening Requirements. 2. The standards below are required for energy efficiency systems, renewable energy production systems, mechanical and elevator equipment, cooling or heating systems, ventilation systems, and ductwork for a building. These systems shall be screened from public view and sited to minimize their visibility and impact. All systems shall comply with the following requirements: a. Equipment shall be combined and co-located unless it is not possible to do so. b. Equipment shall be located on the roof of buildings unless it is not possible to do so, provided that rooftop equipment comply with the standards set in Section 24.04, Screening of Roof-Mounted Appliances. Any equipment located on the ground shall comply with Section 24.09, Transformer and Other Ground-Mounted Appliance Screening. c. When equipment is located on the ground or on an upper level that is not the roof, landscaping or wall enclosures shall be used to screen the unit(s) from view and all ducts shall be incorporated into the interior of the building, and are prohibited from being on a street-facing facade. 3. All trash and recycling receptacles must comply with the standards set in Section 24.05, Location and Screening of Trash Receptacles. Additional requirements are as follows: a. All waste and recycling areas shall be co-located. b. Waste and recycling areas shall be located along an alley or side-street when one exists. c. Waste and recycling areas are not permitted to be located along any street-facing facade. d. When possible, waste and recycling areas shall be incorporated into the main building structure, provided the waste area is serviceable from an alley. I. Landscape Standards. 1. These standards are required for landscaping that is within the public right-of-way. This is defined as the space between the private property line and the back of the curb. 2. Whenever any yard (front, side, or rear) and road right-of-way areas are not designated or used for building, off-street parking, loading and unloading, storage, vehicular traffic or other purpose within the terms and requirements the District, it shall be irrigated and landscaped with either approved natural materials or living plant materials which shall be maintained in an aesthetically pleasing condition, subject to the approval of the city. In instances where pedestrian safety or maintenance is a concern, sod may be approved by the Office of Planning. 3. All trees shall comply with the following standards: a. Three canopy trees per 100 feet of lot perimeter are required. b. Tree canopy shall cover no less than the specified percentage according to Table 14C.05.I.2, Landscape Requirements. The defined percentage represents the canopy coverage at maturity. Refer to "Plant Material Size Table" in Section 24.02, Site Landscaping Requirements for plant material size standards. i. No more than 30% of a single Family (e.g., Aceraceae, Maple), no more than 20% of a single Genus (e.g., Acer) and no more than 10% of a single species (e.g., Acer saccharum) is allowed. ii. Trees shall be planted at least 15 feet from driveways and alleys. iii. The frontage greenbelt width shall be 6 feet for medium trees and 8 feet for all large trees. iv. Medium to large trees shall not be planted closer than 15 feet from any utility poles to allow for line maintenance or lamp posts to provide proper lighting. v. Small trees shall not be planted closer than 10 feet from any utility poles or lampposts. All trees shall be planted a minimum of 10 feet from all fire hydrants, water lines, sewer lines and water sewer mains. vi. Trees shall have a minimum spacing of 30 feet. [image omitted; see the official code] Figure 14C.05.I.2: Tree Canopy 1 Tree canopy shall cover no less than the specified percentage according to Table 14C.05.I.7, Landscape Requirements. The defined percentage represents the canopy coverage at maturity. Refer to "Plant Material Size Table" in Section 24.02, Site Landscaping Requirements for plant material size standards. 2 Trees shall have a minimum spacing of 30 feet. 3. For new development, there shall be three canopy trees per 100 feet in the parkway on each side of each public street. If it is not possible to locate these trees in the parkway, they shall be placed within the exterior yards next to the parkway pursuant to the required count. When located below power lines, however, street trees shall be understory. a. In addition to new planting material, the city may recognize and give one canopy tree credit for each 12 inches of caliper of healthy existing material that is in desirable condition and properly located as determined by the Office of Planning. b. The city may give credit for canopy trees that are planted at a size greater than the required minimum size. The following shall be a basis for the credit: i. Canopy tree or understory tree. For each inch of caliper greater than the minimum required, an inch of credit shall be applied. ii. Evergreen tree or multi-stemmed tree. For each foot in height greater than the minimum required, a foot of credit shall be applied. iii. Deciduous or evergreen shrubs. For each 2 feet in height greater than the minimum required, a foot of credit shall be applied. c. For all residential uses, there shall be a minimum of one canopy tree per dwelling unit located around and/or adjacent to the structure. [image omitted; see the official code] Figure 14C.05.I.3: Tree Graphics 1 The city may give credit for canopy trees that are planted at a size greater than the required minimum size. 2 For all residential uses, there shall be a minimum of one canopy tree per dwelling unit located around and/or adjacent to the structure. 4. In order to promote street tree health and longevity, the tree shall have an adequate volume of soil. The soil volume surrounding a tree shall be 750 cubic feet to 1000 cubic feet per tree, provided that this area is exclusive of the soils volume calculation for adjacent trees. 5. The size specifications for all required planting material shall be pursuant to Article 24, Environmental Provisions. 6. Reference Section 24.02, Site Landscaping Requirements, for all acceptable species. 7. All noxious or exotic weeds identified in the State of Michigan's list of Prohibited and Restricted Species are strictly prohibited. [image omitted; see the official code] Figure 14C.05.I.4: Soil Volume 1 The soil volume surrounding a tree shall be 750 cubic feet to1000 cubic feet (1,000ft3) per tree, provided that this area is exclusive of the soils volume calculation for adjacent trees. Table 14C.05.I.2 Landscape Requirements Standard | District Core | Parkside | Utica Triangle | North Van Dyke Industrial Minimum Tree Canopy (14C.05.I.2) | 50% | 40% | 40% | 40% J. Environmental Preservation and Design Bonuses. 1. Stormwater management/Flood mitigation. a. The applicant is required to utilize some native planting materials which are specified for the climatic zone, topographic and hydrologic characteristics of the site. Refer to subsection 14C.05.I, Landscape Standards for native planting requirements. b. Whenever possible, stormwater management facilities shall be designed as natural features, implementing native deep-rooted shoreline plantings that stabilize the soil, slow runoff, facilitate infiltration and decrease erosion, subject to specific approval by the Office of Planning. Approval shall be based on whether the proposed natural treatment provides an aesthetic and screening benefit to surrounding properties. c. A minimum of five canopy trees per 100 feet of high-water line are required. A minimum of 25% of the required canopy tree shall be non-canopy tree planting material. d. Wherever possible, hard surfaces with non-vehicular traffic or low traffic speeds shall incorporate permeable pavement to allow for infiltration of stormwater runoff into the ground. 2. The use of natural landscaping shall be encouraged adjacent to and within stormwater detention facilities, wetland, low-lying and inactive open space areas. 3. Where feasible, rooftops of commercial, residential, and industrial buildings should incorporate solar panels for energy generation or green roofs for heat distribution efficiency and additional stormwater retention. 4. The following Environmental Design strategies are encouraged per the bonuses identified in Table 14C.05.J.4, Environmental Design Bonuses. Each strategy used shall be in excess of the open space required pursuant to Section 14C.04.A.1, Subdistrict Regulations and Section 24.12, Enhanced Landscaping Features. Each strategy may be used to achieve multiple categories of Design Bonuses. For instance, if a development in the District Core includes three (3) additional strategies, it would qualify for an additional 18 feet of height, a 5% lot coverage reduction, and a 15% parking requirement reduction. Strategies include: a. Native planting areas that are strategically created and contain elements of landscape design. b. Pervious paving. c. Bioswales. d. Green rooftops. e. Rain gardens. f. Infiltration and flow-through planter boxes. g. Level spreaders. h. Cisterns. i. Pollinator gardens. j. Community gardens. k. Planted medians. l. Playgrounds, fields, plazas, or courts. Table 14C.05.J.4 Environmental Design Bonuses Standard | District Core | Parkside | Utica Triangle | North Van Dyke Industrial Additional Height | Each strategy used shall equate to an increase of 6 feet, up to a total of 3 additional stories, above the allowed maximum height. Refer to Table 14C.04.A.1, Subdistrict Dimensional Requirements, for the subdistrict's permitted height. | Each strategy used shall equate to an increase of 6 feet, up to a total of 2 additional stories, above the allowed maximum height. Refer to Table 14C.04.A.1, Subdistrict Dimensional Requirements, for the subdistrict's permitted height. | Each strategy used shall equate to an increase of 6 feet, up to a total of 2 additional stories, above the allowed maximum height. Refer to Table 14C.04.A.1, Subdistrict Dimensional Requirements, for the subdistrict's permitted height. | Each strategy used shall equate to an increase of 6 feet, up to a total of 2 additional stories, above the allowed maximum height. Refer to Table 14C.04.A.1, Subdistrict Dimensional Requirements, for the subdistrict's permitted height. Maximum Lot Coverage Bonus | Two or more strategies shall be implemented to exceed the maximum lot coverage by 5%. Refer to Table 14C.05.B, Lot Coverage and Lot Area Requirements, for the allowed maximum lot coverage. | Two or more strategies shall be implemented to exceed the maximum lot coverage by 5%. Refer to Table 14C.05.B, Lot Coverage and Lot Area Requirements, for the allowed maximum lot coverage. | Two or more strategies shall be implemented to exceed the maximum lot coverage by 5%. Refer to Table 14C.05.B, Lot Coverage and Lot Area Requirements, for the allowed maximum lot coverage. | Two or more strategies shall be implemented to exceed the maximum lot coverage by 5%. Refer to Table 14C.05.B, Lot Coverage and Lot Area Requirements, for the allowed maximum lot coverage. Parking Requirement Reduction | Parking shall be reduced by 5% for each strategy used. An additional 5% reduction is permitted for a pedestrian pass-through that complies with Section 24.10. Pedestrian Connections and 14C.05.F.4. Reductions are limited to up to 40% of the required maximum. | Parking may be reduced by 5% for each strategy used. An additional 5% reduction is permitted for a pedestrian pass-through that complies with Section 24.10. Pedestrian Connections and 14C.05.F.4. Reductions are limited to up to 20% of the required maximum. | Parking may be reduced by 5% for each strategy used. An additional 5% reduction is permitted for a pedestrian pass-through that complies with Section 24.10. Pedestrian Connections and 14C.05.F.4. Reductions are limited to up to 20% of the required maximum. | Parking may be reduced by 5% for each strategy used. An additional 5% reduction is permitted for a pedestrian pass-through that complies with Section 24.10. Pedestrian Connections and 14C.05.F.4. Reductions are limited to up to 20% of the required maximum. K. Ground Floor Uses. 1. Buildings shall include active uses that support the vibrancy and usability of adjacent public realm and encourage walk-in traffic. The following standards only apply to buildings that are two or more stories in height. a. A portion of the length of any street-facing facade on the ground floor of all new buildings shall consist of active uses that occupy a minimum portion according to Table 14C.05.K.1, Active Use Requirements. b. Vehicle entry and exit ways necessary for access to parking are exempt from this requirement. Such accessways shall not exceed 30 feet in width and shall meet the requirements identified in Table 14C.05.E.3, Entrances Requirements. Table 14C.05.K.1 Active Use Requirements Standard | District Core | Parkside | Utica Triangle | North Van Dyke Industrial Minimum Active Uses (14C.05.K.1.a) | 80% | 75% | 75% | 65% L. Modifications. 1. Following approval of the use, development, building, structure, site plan, or variance by the Planning Commission, the Zoning Board of Appeals, and/or the City Council, as applicable, the Office of Planning may approve, in its sole discretion, minor modifications, including, but not limited to, the following: a. Modifications of up to 10% of the dimensional requirements set forth in Section 14C.04.A.1, Subdistrict Regulations. b. Modifications of up to 10% of the 100-foot watercourse buffer required in Section 14C.05.D, Parkside Subdistrict. c. Modifications of up to 10% of the standards set forth in Section 14C.05, Building/Site Design. (Ord. No. 278-NNN, 2-4-25)

Ask a question about Sterling Heights law

Corpus searches the Sterling Heights sections it holds and shows the ones that match, with their citations. Free, no sign-in.