§ 20-23 — LOCAL AMENDMENTS TO INTERNATIONAL FIRE CODE

Code of Ordinances of the City of Sterling Heights, Michigan (2026 S-46: Local legislation current through Ord. 509, passed 5-19-26) · Sterling Heights City Code § 20-23

Corpus is an independent public-information project, not the official City of Sterling Heights website. Stable reference: corpuslaw.us/code/af431b97-e2b0-4c1e-b62d-9ee16aa45831

20-23. LOCAL AMENDMENTS TO INTERNATIONAL FIRE CODE.

The International Fire Code, 2024 edition, shall govern generally all fire prevention and protection matters in the City of Sterling Heights. To further the goal of protecting the public health, safety, and welfare of the residents and businesses of the city, the following sections of the International Fire Code, 2024 edition, and Appendix D therein, are amended or added as set forth in the following paragraphs: Section 101.1 shall be amended to read as follows: 101.1. Title. These regulations shall be known as the Fire Code of the City of Sterling Heights, hereinafter referred to as "this code." Section 102.3 shall be amended to read as follows: 102.3. Change of use or occupancy. A change of occupancy shall not be made unless the use or occupancy is made to comply with the requirements of this code and the Michigan Building Code. Exception: Where approved by the fire code official, a change of occupancy shall be permitted without complying with the requirements of this code and the Michigan Building Code, provided that the new or proposed use or occupancy is less hazardous, based on life and fire risk, than the existing use or occupancy. Section 102.4 shall be amended to read as follows: 102.4. Application of building code. The design and construction of new structures shall comply with the Michigan Building Code, and any alterations, additions, changes in use, or changes in structures required by this code, which are within the scope of the Michigan Building Code, shall be made in accordance therewith. Section 102.6 shall be amended to read as follows: 102.6. Historic buildings. The construction, alteration, repair, enlargement, restoration, relocation or movement of existing buildings or structures that are designated as historic buildings, when such buildings or structures do not constitute a distinct hazard to life or property, shall be in accordance with the provisions of the Michigan Building Code. Fire protection in designated historic buildings shall be provided with an approved fire protection plan as required in Section 1103.1.1. Section 102.10 shall be amended to read as follows: 102.10. Conflicting provisions. Where there is a conflict between a general requirement and a specific requirement within this code, the specific requirement shall be applicable. Nothing in this code shall be construed, interpreted, or applied to abrogate, nullify, or abolish any law, ordinance, or code adopted by the jurisdiction relating to structures, processes, and premises and safeguards from the hazard of fire and explosion arising from the storage, handling, or use of structures, materials, or devices specifically provided herein. When any provision of this code is found to be in conflict with any building, zoning, safety, health, or other applicable law, ordinance, or code of the city existing on the effective date of this code or hereafter adopted, the provision which establishes the higher standard for the promotion and protection of the safety and welfare of the public, as determined by the Fire Chief or the Fire Chief's designee, shall prevail. Where, in a specific case, different sections of this code specify different materials, methods of construction, or other requirements, the most restrictive shall govern. In the event any conflict exists between this code and any law, ordinance, code provision, standard, or recommended practice, which conflict is not resolved by the terms of this or any other section of this code, the City Manager of the City of Sterling Heights or the City Manager's designee shall determine which code shall be applicable. Section 103.2 shall be amended to read as follows: 103.2. Appointment. The fire code official is the Fire Chief, or a duly authorized representative, and is appointed as provided by the City Charter or other applicable law. Section 104.1.1 shall be added to read as follows: 104.1.1. Restriction of employees. An official or employee connected with the enforcement of this code, except one whose only connection is that of a member of the Board of Appeals established under the provisions of Section 111, shall not be engaged in, or directly or indirectly connected with, the furnishing of labor, materials, or appliances for the construction, alteration, or maintenance of a structure or the preparation of construction documents thereof, unless that person is the owner of the structure; nor shall such officer or employee engage in any work which conflicts with official duties or with the interests of the Fire Department or city. Section 104.1.2 shall be added to read as follows: 104.1.2. Rules and regulations specified. All rules promulgated under the authority of 104.1 shall have the same effect and enforceability as any other provision of this code. Such promulgated rules and regulations shall include but not be limited to: A. The requirements identified as the Sterling Heights Fire Department, Fire Prevention Division Construction Requirements. B. All regulations promulgated by, and on file at, the Sterling Heights Fire Department, including but not limited to the following subjects: 1. Fire Protection Systems; 2. Fire Alarm Systems; 3. Fire Protection for Commercial Cooking Equipment; 4. Open Burning; 5. Safe Operations/Maintenance at Gasoline Stations; 6. Emergency Planning and Preparedness; 7. Hazardous Chemical Reporting (Right-to-Know); 8. Draftstopping; 9. No Parking - Fire Lane Signs; 10. Rapid Entry Systems; 11. Yard Hydrant Identification; 12. Smoke Vent Identification; 13. Hazardous Stack Marking; 14. Fire Hydrant Impact Protection; 15. Fire Hydrant Access Gates; 16. Fire Apparatus Access Roads; 17. Addresses and Thoroughfare Signs; 18. Utility Meter and Appliance Impact Protection; 19. Security Gates - Emergency Operation; 20. Tents and Other Membrane Structures; 21. Temporary and Portable Cooking Facilities; 22. Consumer Fireworks Sales; 23. Fireworks Displays; 24. Proximate Audience Pyrotechnics; 25. Special Amusement Buildings; 26. Indoor Art & Craft Fairs, Festivals, and Similar Events; 27. Outdoor Carnivals, Festivals, Fairs, and Similar Events 28. Mobile Food Preparation Vehicles; 29. CO2 Detection; 30. Residential Garage Uses; and 31. False Alarms and Maintenance/Repair of Fire Systems. C. Sterling Heights Fire Department, Fire Prevention Division, Fire Marshal Bulletins. Section 104.1.3 shall be added to read as follows: 104.1.3. Rules and regulations continued. All written policy statements promulgated and/or issued by the fire code official for clarification of a provision of this code, or as a guide for a provision of this code, or as a rule or regulation regarding an issue not specifically or thoroughly addressed in the code shall have the same effect and enforceability as any other provision of this code. Section 104.8.1 shall be amended to read as follows: 104.8.1. Legal defense. Any suit instituted against any officer or employee because of an act performed by that officer or employee in the lawful discharge of duties and under the provisions of this code shall be defended by the City Attorney if such defense is covered and approved by the city's legal defense insurance carrier. The fire code official or any subordinate shall not be liable for costs in an action, suit, or proceeding that is instituted for actions in pursuance of the provisions of this code; and any officer of the Fire Department, acting in good faith and without malice, shall be free from liability for acts performed under any of its provisions or by reason of any act or omission in the performance of official duties in connection therewith. Section 104.10 shall be amended to read as follows: 104.10. Fire investigations. The fire code official, the Fire Department, or other responsible authority shall have the authority to investigate the cause, origin, and circumstances of any fire, explosion, or other hazardous condition. Such investigation shall be initiated immediately upon the occurrence of such fire, explosion, or incident; and if it appears that such an occurrence is of a suspicious nature, the fire code official shall immediately take charge of the physical evidence; and, in order to preserve any physical evidence relating to the cause or origin of such fire or explosion, the fire code official shall take means to prevent access by any person to the structure or premises until such evidence has been properly processed. The fire code official shall notify those persons designated by law to pursue investigations into such matters and shall further cooperate with the authorities in the collection of evidence and prosecution of the case and shall pursue the investigation to its conclusion. Information that could be related to trade secrets or processes shall not be made part of the public record except as directed by a court of law. Section 104.11.2 shall be amended to read as follows: 104.11.2. Obstructing operations. No person shall obstruct the operations of the fire department in connection with extinguishment or control of any fire, or actions relative to other emergencies, or disobey any lawful command of the fire chief or officer of the fire department in charge of the emergency, or any part thereof, or any lawful order of a police officer assisting the fire department, or interfere with the compliance attempts of another individual. Section 104.11.4 shall be added to read as follows: 104.11.4. Unlawful boarding or tampering. A person shall not, at any time and without authorization from the fire chief or authorized fire official, cling to, attach himself or herself to, climb upon or into, board, or swing upon any fire department emergency vehicle, whether the same is in motion or at rest, or sound the siren, horn, bell, or other sound-producing device thereon or to manipulate or tamper with any levers, valves, switches, starting devices, brakes, pumps, or any equipment or protective clothing on, or a part of, any fire department emergency vehicle. Section 104.11.5 shall be added to read as follows: 104.11.5. Injuring fire department personnel. No person shall injure, or attempt or conspire to injure, Fire Department personnel who are performing official duties. Section 105.1.1 shall be amended to read as follows: 105.1.1. Permits required. A property owner or owner's authorized agent who intends to conduct an operation or business, or install or modify systems and equipment that are regulated by this code, or to cause any such work to be performed, shall first make application and obtain the required permit. When a permit is required by this code, the fire code official shall have discretion to require an inspection and approval in lieu of a formal permit. A permit shall not be issued until the designated fees, if any, have been paid. The permit fees, inspection fees, and any other fees shall be set by the city council in its annual appropriations ordinance. Issued permits shall be kept on the premises designated therein at all times and shall be readily available for inspection by the fire code official. Section 105.1.2 shall be amended to read as follows: 105.1.2. Types of permits. There shall be two types of permits as follows: A. Operational permit. An operational permit allows the applicant to conduct an operation or a business for which a permit is required by Section 105.5 for either: (1) A prescribed period. (2) Until renewed or revoked. B. Construction permit. A construction permit allows the applicant to install or modify systems and equipment for which a permit is required by Section 105.6. All applications for construction permits shall be submitted to the building official for review and issuance or denial. The building official shall submit the applications to the fire marshal for review and recommendations. Section 105.2 shall be amended to read as follows: 105.2. Application. Application for a permit required by this code shall be made to the fire code official in such form and detail as prescribed by the fire code official. Applications for permits shall be accompanied by such plans as prescribed by the fire code official. All applications for permit shall include the date of birth and a copy of the driver's license or state-issued identification of the applicant, which shall be verified at the time the application is taken. Section 105.5.16 shall be amended to read as follows: 105.5.16. Explosives. An operational permit is required for the manufacture, storage, handling, sale, or use of any quantity of explosive, explosive material, fireworks, or pyrotechnic special effects within the scope of Chapter 56. Pursuant to Michigan law, the City shall issue or deny fireworks display permits as set forth elsewhere in Chapter 20 of the City Code. Section 105.5.34 is amended to read as follows: 105.5.34. Mobile food preparation vehicles. An operational permit is required for all mobile food preparation vehicles and trailers. In addition to the requirements set forth in fire department regulations, at a minimum an applicant for a permit shall include with the properly completed permit application a copy of its current county health department mobile food vendor permit, a copy of its current certificate of insurance, and a copy of the results of its annual LP gas system inspection/leakage test required by section 4106. Section 105.6 shall be amended to read as follows: 105.6. Required construction permits. The fire code official shall review and provide a response and/or recommendations to the building official regarding construction permits for work as set forth in Sections 105.6.1 through 105.6.25. Section 110.2.2 shall be added to read as follows: 110.2.2. Test and inspection records. All installation, inspection, and test records and reports relating to the requirements of this Code shall be electronically transmitted to the fire department, within seven (7) days, through an electronic information data manager designated by the City to facilitate the collection and transmission of such reports. The reports shall be in a format designated by the electronic information data manager. Section 110.2.2.1 shall be added to read as follows: 110.2.2.1. Registration required. Every service provider that performs inspections, repairs, and/or tests within the City, and any entity that performs self-inspections or in-house inspections within the City, shall be registered with, and approved by, the Fire Marshal and shall register with the City's designated electronic information data manager in order to comply with subsection 110.3 before performing any inspections and/or tests within the City. No fee shall be assessed for registering as required by this subsection. Failure to comply with this subsection shall be punishable first by a written warning notice, followed for subsequent violations by the issuance of a municipal civil infraction, punishable as set forth in Section 1 of the City Code. The Fire Chief shall designate, and the electronic information data manager shall advise each service provider and affected entities or properties of, the inspections and tests for which the requirements of this subsection will apply. By way of example and not limitation, the requirements of this subsection will apply to fire alarm inspections, backflow inspections, fire pump tests, and inspections or testing of sprinkler systems, fire extinguishers, emergency lighting, and UL-300 kitchen hood semi-annual inspections and cleanings. The Fire Chief may only waive the electronic reporting requirements of this subsection for cases of extreme hardship outside the control of the company or entity that performed the inspection and/or test. Section 110.2.2.2 shall be added to read as follows: 110.2.2.2. Approved service providers. Every business subject to fire inspections and/or tests within the City shall utilize a service provider that has registered with, and been approved by, the Fire Marshal. A list of such providers shall be made available at no charge upon request by a business within the City, and will be periodically updated on the City's website. Inspections and/or tests that are conducted in violation of this subsection shall not be accepted or deemed valid for purposes of compliance with the Code. A service provider may only be disapproved or removed from the approved registrations for good cause, which includes but is not limited to lack of technological capability to comply with this subsection; refusal to comply with this subsection; a history of noncompliance without reliable assurance of future compliance; indebtedness to the City; property maintenance violations; convictions, pleas, or actions involving fraud or moral turpitude; and such other good cause as the Fire Chief may establish in an operating guideline and which is reasonably related to the protection of the public health, safety, and welfare. Section 112.1 shall be amended to read as follows: 112.1. Board of Appeals. The city has created a Board of Code Appeals to hear and decide appeals of orders, decisions, or determinations made by the fire code official relative to the application and interpretation of this code. The members, qualifications, and procedures for the Board of Code Appeals are set forth in Chapter 2 of the City Code. The fire code official shall be an ex officio member of the Board of Code Appeals when it convenes to address issues and matters which arise under this code, and shall be notified by the City of all meetings of the Board, but shall have no vote on any matter before the Board. Section 112.2 shall be amended to read as follows: 112.2. Application for appeal. Any person shall have the right of appeal to the Board of Code Appeals from a decision of the fire code official. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply, or an equally good or better method of fire prevention is used, or that a variance to the provisions of this code should be approved in accordance with provisions of Section 112.3. The application for appeal shall be in writing and shall be accompanied by an application fee as established by the City's annual appropriations ordinance. The application shall explain the exact nature of the appeal and shall be received by the fire code official within 20 days after the notice of violation was served to be considered timely. An appeal will be considered by the Board of Code Appeals in the event that it is filed after 20 days only upon a showing of good cause to the fire code official as to why the appeal was not filed within the time period provided herein. Section 113.3.3 shall be amended to read as follows: 113.3.3. Prosecution of violations. If the notice of violation is not complied with promptly, the fire code official is authorized to request the City Attorney to institute the appropriate legal proceedings at law or in equity to restrain, correct, or abate such violation or to require removal or termination of the unlawful occupancy of the structure in violation of the provisions of this code or of the order or direction made pursuant thereto. The Police Department shall be requested by the fire code official to make arrests for any offense against this code or orders of the fire code official affecting the immediate safety of the public. Section 113.3.5 shall be added to read as follows: 113.3.5. Appearance tickets. When in the opinion of the fire code official and/or his or her designate, there exists an apparent or actual violation of a provision of this code or other codes or ordinances under the fire code official's jurisdiction and the violation is of a nature that requires immediate attention or abatement, the fire code official and/or his or her designate(s) are hereby empowered to issue appearance tickets to the party or parties responsible for correction and/or abatement of the violation. The appearance ticket shall serve as notice that immediate action is required to abate hazardous condition(s) or situation(s) and shall require the appearance of the responsible party or parties in a court of law for violating the provisions of this code. Section 113.4 shall be amended to read as follows: 113.4. Violation penalties. Persons who shall violate a provision of this code or shall fail to comply with any of its requirements or who shall erect, install, alter, repair, or do work in violation of the approved construction documents or directive of the fire code official, or of a permit or certificate used under provisions of this code, shall be subject to the penalties set forth in Chapter 1 of the City Code. Regardless of any provision to the contrary in the City Code: (1) A person who disobeys or resists an order of the fire code official to vacate a premises or structure, or to undertake, or omit to undertake, an act which the fire code official deems necessary to abate or mitigate an immediate threat to public safety, shall be guilty of a misdemeanor punishable by imprisonment for up to 90 days or a fine up to $500.00, or both. Each day that a violation continues after due notice has been served shall be deemed a separate offense. Section 114.4 shall be amended to read as follows: 114.4. Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be responsible for a municipal civil infraction and subject to a fine set forth in Chapter 1 of the City Code for the first offense. If the person continues to work in violation of a stop work order under this section after receiving a municipal civil infraction citation, the person shall be guilty of a misdemeanor punishable by imprisonment for up to 90 days or a fine of not less than $250 and not more than $500, or both. Section 115.1 shall be amended to read as follows: 115.1. General. During the inspection of a premises, if a building or structure or any building system, in whole or in part, constitutes a clear and inimical threat to human life, safety, or health, the fire code official shall issue such notice or orders to remove or remedy the conditions as shall be deemed necessary in accordance with this section and shall refer the building to the building official for any repairs, alterations, remodeling, removing, or demolition required. By way of illustration only, the following are deemed to be hazardous conditions: (A) Hazardous conditions liable to cause or contribute to the spread of fire in or on said premises or structure or endanger the occupants thereof; (B) Conditions that interfere with the efficiency or operation of any fire protection equipment and systems; (C) Obstructions to or on fire escapes, stairs, passageways, doors, or windows, that are liable to interfere with the egress of occupants or the operation of the fire department in case of a fire; (D) Accumulations of dust or waste material in air-conditioning or ventilating systems or grease in kitchen or other exhaust ducts; (E) Accumulations of grease on kitchen cooking equipment, or oil, grease, or dirt upon, under, or around any mechanical equipment; (F) Accumulations of rubbish, waste, paper, boxes, shavings, or other combustible materials, or excessive storage of any combustible/hazardous material; (G) Hazardous conditions arising from defective or improperly utilized or installed electrical wiring, equipment, or appliances, including but not limited to installing or using generators for more than a temporary source of power or in a manner not in accordance with the manufacturer's specifications or user manual; (H) Defective exit and emergency lighting systems; (I) Hazardous conditions arising from defective or improperly installed equipment for handling or using combustible, explosive, or otherwise hazardous materials; (J) Dangerous or unlawful amounts of combustible, explosive, or otherwise hazardous materials; and (K) All equipment, materials, processes, or operations that are in violation of the provisions or intent of this code. Section 115.1.1 shall be amended to read as follows: 115.1.1. Unsafe conditions. Structures or existing equipment that are or hereafter become unsafe or deficient because of inadequate means of egress or which constitute a fire hazard, or are otherwise dangerous to human life or the public welfare, or which involve illegal or improper occupancy or inadequate maintenance, or are residences without heat or power or which are otherwise uninhabitable due to hoarder conditions, biohazards, lack of running water, or animal/human waste, shall be deemed an unsafe condition and a violation of this code. A vacant structure which is not secured against unauthorized entry as required by Section 311 shall be deemed unsafe and a violation of this code. Unsafe structures or equipment shall be reported to the building official who shall take appropriate action as deemed necessary under the provisions of the Building Code. When a structure is rendered unsafe, dangerous, or hazardous due to fire, explosion, or other conditions whether man-made or natural, the fire code official may order the structure be secured against trespass. Section 115.7 shall be amended to read as follows: 115.7 Summary abatement. Where conditions exist that are deemed hazardous to life and property, the fire code official or fire department official in charge of the incident is authorized to abate summarily such hazardous conditions that are in violation of this code by any means deemed appropriate to ensure or mitigate against dangers to life and property, including but not limited to utilizing locking mechanisms or other access barriers to prevent entry or occupancy by anyone not approved by the fire code official to be in or on a hazardous premises. Section 202 shall be amended to include the following definitions: INDEPENDENT LIVING FACILITY. A residential living facility that markets itself to senior citizens as providing, or which actually provides or offers, staff to serve its residents in a communal living environment for 24 hours per day, hospitality services, and/or convenient access to dining, medical care, hospitality services, and/or entertainment. MICHIGAN BUILDING CODE. References to the International Building Code or the Michigan Building Code shall mean the most recent edition of the Michigan Building Code, as promulgated by the Director of LARA, and as adopted in Chapter 11 of the City Code and enforced by the city, or any code or document which succeeds or replaces such document. Section 202 shall be amended to amend the following definitions: BONFIRE. An outdoor fire utilized for occasional special events and which burns only seasoned dry firewood intended to minimize the generation of air contaminants. A permit is required for all bonfires. ENERGY STORAGE SYSTEM (ESS). One or more devices, assembled together, capable of storing energy in order to supply electrical energy at a future time, including but not limited to batteries or battery components that are utilized in the powering of equipment, vehicles, or mobility devices. KNOXBOX®. A secure device with a lock operable only by a fire department master key, and containing building entry keys and other keys that may be required for access in an emergency. The City requires a KnoxBox® type of key box, unless a fire marshal bulletin authorizes a different type, for uniformity, security, access, and long-term durability (see Chapter 5). MOBILE FOOD PREPARATION VEHICLES. Vehicles and/or trailers that contain cooking and/or food preparation equipment for the purpose of preparing and serving food to the public. Vehicles intended for private recreation shall not be considered mobile food preparation vehicles. OPEN BURNING. The burning of materials wherein products of combustion are emitted directly into the ambient air without passing through a stack or chimney from an enclosed chamber. OPEN BURNING does not include road flares, smudgepots, and similar devices associated with safety or occupational uses typically considered open flames. For the purpose of this definition, a chamber shall be regarded as enclosed when, during the time combustion occurs, only apertures, ducts, stacks, flues, or chimneys necessary to provide combustion air and permit the escape of exhaust gas are open. RECREATIONAL FIRE. An outdoor fire burning only dry, seasoned firewood or commercially available charcoal briquettes on the ground in a prepared pit having a total fuel area of 4 feet or less in diameter and 2 feet or less in height for pleasure, warmth, or cooking food for human consumption. A permit is required for all recreational fires. Section 305.1 shall be amended to read as follows: 305.1. Clearance from ignition sources. Clearance between ignition sources, such as light fixtures, luminaires, heaters and flame-producing devices, electrical service equipment, and combustible materials shall be maintained in an approved manner. Section 307.1.2 shall be added to read as follows: 307.1.2 Allowable open burning. The following types of open burning shall be allowed without prior notification to the fire code official and without a permit, and shall be constantly attended: A. Commercially-built barbecues and smokers, when cooking food for human consumption using only charcoal briquettes, LP-gas, pellets, or natural gas for fuel. B. UL-listed outdoor fireplaces, which may burn only dry, seasoned firewood, and shall not burn between the hours of 11:00 p.m. and 7:00 a.m., and must be utilized in accordance with manufacturer's specifications. Example: Fire pits and chimeneas purchased from stores are acceptable, so long as the pit or chimenea is constructed of metal or ceramic, has a solid top, has steady legs to keep it off of the ground and anchor it against falling over, has a spark arrestor constructed of iron, heavy wire mesh, or other non-combustible material with openings not larger than 1/2 inch, and has a spark arrestor or screen on the top and/or sides. No fuels (logs, wood, etc.) shall be allowed to protrude out of the top of the pit or from the sides. C. Controlled fires by qualified instructors for fire suppression training, e.g., firefighter training, industrial fire brigade training, employee training for portable fire extinguishers. D. Heating of building materials or for the warmth of workers at construction sites burning only charcoal, dry, seasoned firewood, or other approved fuel, in an approved container. Section 307.2 shall be amended to read as follows: 307.2. Permit required. A permit shall be obtained from the fire code official in accordance with Section 105.5 prior to kindling a bonfire or a recreational fire. Application for such approval shall only be presented by and permits issued to the owner of the land upon which the fire is to be kindled. Applications shall be submitted in writing at least ten days prior to the proposed event and shall be in such form and contain such information as required by the fire code official. Section 307.3 shall be amended to read as follows: 307.3. Extinguishment authority. The fire code official is authorized to order the extinguishment by the permit holder, another person responsible for the fire, or the Fire Department of open burning that creates or adds to a hazardous or objectionable situation, or which constitutes air pollution, defined in the Natural Resources and Environmental Protection Act as the presence in the outdoor atmosphere of air contaminants in quantities, of characteristics, under conditions and circumstances, and of a duration that are or can become injurious to human health or welfare, to animal life, to plant life, or to property, or that interfere with the enjoyment of life and property in this state. Section 307.4 shall be amended to read as follows: 307.4 Location. The location for open burning shall not be less than 50 feet from any structure, other combustible appurtenances or material, public rights-of-way, and property lines, and provisions shall be made to prevent the fire from spreading to within 50 feet of any structure. Exceptions: 1. Fires in approved containers that are not less than 15 feet from a structure, other combustible material, public rights-of-way, and property lines. 2. (Intentionally Deleted) Section 307.4.1 shall be amended to read as follows: 307.4.1 Bonfire dimensions, duration, and location. A bonfire shall not be more than 6 feet by 6 feet by 6 feet in dimension and shall not burn longer than 4 hours. The location of a bonfire shall be in accordance with Section 307.4. Section 307.4.2 shall be amended to read as follows: 307.4.2 Recreational fire dimensions, duration, and location. A recreational fire shall have a fuel area of 4 feet or less in diameter and 2 feet or less in height and shall not burn longer than 4 hours. The location of a recreational fire shall be in accordance with Section 307.4. Section 308.1.11 shall be added to read as follows: 308.1.11 Open-flame cooking devices. Charcoal burners and other open-flame cooking devices shall not be operated or stored on combustible balconies or within 10 feet of combustible construction. Exceptions: 1. One- and two-family dwellings. 2. Where buildings, balconies, and decks are protected by an automatic sprinkler system. Section 308.1.7 shall be amended to read as follows: 308.1.7 Sky lanterns. Sky lanterns shall not be used, ignited, launched, offered for sale, exposed for sale, sold at retail, or kept with intent to sell at retail. Additional regulations governing sky lanterns are set forth in Chapter 20 of the City Code. Section 315.4.3 shall be added to read as follows: 315.4.3 Proximity to buildings. Outside storage of combustible materials shall not be located within 10 feet (3048 mm) of a building or structure without adequate fire suppression, as determined by the fire code official under this code, for the materials being stored. Section 315.8 shall be added to read as follows: 315.8 Shipping and storage containers. Shipping containers and storage containers, if permitted by City ordinance, shall not be placed or maintained in a manner that obstructs fire access lanes, ladder access, or fire department connections, or in a manner that obstructs, blocks, or impairs the visibility or accessibility of fire hydrants, or in a manner that conflicts with the requirements of this code, and shall have separations sufficient to allow for laddering every building or structure on the premises. A permit approved by the fire code official is required for all shipping containers and storage containers, as defined in the City's zoning ordinance, if otherwise permitted as a use under the City's zoning ordinance. Section 310.7.1 shall be amended to read as follows: 310.7.1 Multi-family dwellings. Lighted matches, hookah devices, chimeneas, candles, lit fireworks, or any other type of open or exposed flame is prohibited on or within 10 feet of a combustible balcony, patio, landscaped area (for example, wood chips or mulch), or porch of a multi-family dwelling unit. Any unexposed flame devices or burning/burnt remnants of a flame shall be discarded immediately utilizing only an approved method or device. Section 323 shall be added to read as follows: SECTION 323—ENERGY STORAGE SYSTEM AND BATTERY CHARGING 323.1 Charging. Energy storage systems, lithium-ion batteries, and lithium metal batteries, whether attached to or detached from a powered mobility device (such as an electric vehicle) or a powered micromobility device, may only be charged within or under any building or structure designed or used for habitation if the area is designed in accordance with fire code official bulletins and/or regulations. Section 324 shall be added to read as follows: SECTION 324—RESIDENTIAL GARAGE COOKING 324.1 Intent. A garage attached or detached from a residential home or structure is intended to provide off-street vehicular parking and incidental household storage for the occupants of the residents to which it is accessory. The intent of this section is to establish fire safety standards for garages and activities therein which are tailored to limit and mitigate fire hazards, fire risk, fire severity, and other conditions detrimental to public safety. 324.2 Cooking prohibited. Unless the garage has been converted into habitable space through the issuance and maintenance of all applicable permits from the city, no garage shall be used for cooking or have any functional cooking facilities or equipment installed or kept therein. 324.3 Definitions. For purposes of this section, the following terms shall be defined as follows: Cooking. The use of cooking facilities or equipment to heat or prepare food or liquids for consumption, including but not limited to frying, baking, grilling, broiling, boiling, blanching, roasting, toasting, heating, or poaching. Cooking facilities or equipment. Any device, apparatus, or appliance that is fuel-fired, utilizes an open flame, or utilizes electrical power in excess of 110 volts and is designed or capable of being used for the cooking, preparation, or heating of food. Garage. An accessory building or portion of a main building designed, designated, constructed, or used for the storage of motor-driven vehicles, boats, and similar vehicles and equipment owned and used by the occupants of the building to which it is accessory. Habitable space. Space within a structure for living, sleeping, or cooking. Section 503.2.9 shall be added to read as follows: 503.2.9 Modifications. The fire code official shall have the authority to require or permit modifications to the requirements of this section, through the implementation of Fire Prevention Regulations or during plan and permit review processes, including but not limited to access widths, speed calming devices, dead-end road turnaround dimensions, and fire lane parking restrictions, where they are inadequate for fire or rescue operations or where necessary to meet the public safety objectives of the City. Section 503.4.1 shall be amended to read as follows: 503.4.1. Traffic calming devices. Traffic calming devices are prohibited unless approved by the Fire Department in accordance with a Fire Department regulation enacted by the Fire Chief. Section 503.6.1 shall be added to read as follows: 503.6.1. Approved means of emergency operation. Unless the security gate is constantly attended (24 hours per day, 7 days per week) by a responsible person employed for the purpose of monitoring and administering the security gate, the following rules shall apply for all electronically operated gates: 1. The gate(s) shall be provided with an approved Siren Operated Sensor (S.O.S.) designed to trigger any brand of gate operator within 3-5 seconds. It shall have a minimum 10 minute hold. It shall have a battery back-up system for continuous duty or open and hold until line power is restored. In all cases the gate(s) must be accessible to 9-1-1 emergency responders. A suitable label/sign shall be installed to remind Fire, Police, and E.M.S. that an S.O.S. system is installed. 2. If the facility has a fire alarm system the gate(s) shall be opened and held open automatically on initiation of the alarm. 3. An approved manual override, KnoxBox®, or similar access shall be provided. If the manual override requires a key it shall conform to the system approved by the Fire Department. 4. A code number shall be required to allow the Police Department to make silent entry. 5. Swing gates shall open in the direction of entry. The gate width shall be indicated on the exit side so that vehicles may stop far enough away to allow for safe exiting. 6. The gates shall be set back from the approach a minimum of 30 feet to allow emergency vehicles to be pulled off of the road while initiating gate opening. 7. Applicants for gated access roads must be willing to change to another approved type of access system if such a system is required at a future date. All maintenance and revisions shall be at the expense of the entity responsible for maintaining the gate. Section 503.6.2 shall be added to read as follows: 503.6.2. Violation, penalty. No person shall permit, cause, or otherwise allow Section 503.6.1 to be violated. Failure to ensure constant attendance, or failure to ensure compliance with the listed rules, shall constitute a misdemeanor punishable as provided in Chapter 1 of the City Code. Employers, owners or presidents of corporations, or other persons with similar authority may be charged with a violation of this section for failure to supervise and ensure compliance with Section 503.6.1. Any person who fails or refuses to afford immediate access through security gates to fire, police, or other emergency personnel who are engaged in rendering emergency services or otherwise performing lawful duties shall be guilty of a misdemeanor. Section 504.3 shall be amended to read as follows: 504.3. Stairway access to roof. New buildings four or more stories above grade plane, except those with a roof slope greater than 4 units vertical in 12 units horizontal (33.3-percent slope), shall be provided with a stairway to the roof. Stairway access to the roof shall be in accordance with Section 1011.12. Such stairway shall be marked at street and floor levels with a sign indicating that the stairway continues to the roof. Where the roof is a vegetative roof, includes a landscaped roof area, or is used for other purposes, stairways shall be provided as required for such occupancy classification. Doors that provide access to the roof from a stairway shall not be locked or secured without approval of the fire code official, but may be protected by a local alarm system and marked accordingly. Section 505.1 shall be amended to read as follows: 505.1. Address identification. All buildings shall have permanent conspicuous addresses in accordance with Chapter 11 of the City Code. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. The fire code official may require supplemental building identification or modify the size or location of such identification as deemed necessary to insure that each and every building is properly identified to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole, or other sign or means shall be used to identify the structure. Section 506 shall be replaced and shall read as follows: SECTION 506 RAPID ENTRY SYSTEMS 506.1 Required. Commercial buildings, including properties with a locked gate or driveway which allows access to a commercial building or business, shall install an approved KnoxBox® within 90 days of written notice from the fire code official or designee. In addition, and in the sole discretion of the Fire Marshal, a KnoxBox® shall be required in any building where lack of access may result in loss of life and/or large property or environmental damage, based on factors including, but not limited to, fire load, occupant load, exposures, building construction, age of building, and storage or use of hazardous materials. 506.2 Maintenance. The responsible party shall immediately notify the fire code official when any or all of the locks or keys have been changed and shall keep the immediate area of the KnoxBox® free and clear of any and all obstructions. The responsible party shall provide the proper keys for the KnoxBox® to the Fire Department and shall not have access to a key that can open the KnoxBox®. 506.3 Requirements. The responsible party is required at all times to keep a key(s) in the KnoxBox® that will allow access to, and/or into, the structure. The KnoxBox® shall contain, but not be limited to, the following items as designated by the fire code official: a. Labeled keys to locked points of egress, whether in interior or exterior of the building; b. Labeled keys to the locked mechanical and electrical rooms; c. Labeled keys to locked elevator rooms and controls; d. Labeled keys to any fence or secured areas; e. Labeled keys to areas of the building where fire alarm panels and fire protection systems are located; f. Labeled keys to any other areas as required by the fire code official; g. A card containing the emergency contact people and phone numbers for the building; h. Floor plans of the rooms within the building showing locations of shut-offs; i. Hazardous materials information; j. An inventory of the keys inside all KnoxBoxes®; k. Digital codes for access to any gates or any electronic door locks within the building; l. Any other keys, instructions, and/or information required by the Fire Department's administrative regulations and guidelines. 506.4 Registration and installation. The responsible party shall apply for a registration for a KnoxBox® on forms provided by and obtained from the fire code official. A registration is required prior to the installation of a KnoxBox® in order to verify the proper mounting location and installation of the KnoxBox®. The KnoxBox® shall be installed on the exterior of the building at a location and in a manner approved by the fire code official. No KnoxBox® shall be installed, voluntarily or otherwise, without first obtaining the approval of the fire code official. The responsible party shall be responsible for the cost to purchase, install, and maintain the KnoxBox®. 506.4.1 Opt out. Any property owner not otherwise exempt may opt out of the KnoxBox® program if the property perpetually maintains personnel on the site who have, and can provide, access to the property and structures on the property to first responders and emergency personnel. To exercise the opt out, the property owner must obtain the written approval of the fire code official, which shall only be granted if the fire code official is satisfied, in his or her sole discretion, that the property does and will perpetually maintain the required personnel on the site, and shall be subject to immediate revocation in the event the property fails to do so. Additionally, all owners of such premises shall execute and deliver to the fire code official an agreement, in the form and substance required by the City Attorney, holding the City of Sterling Heights and all neighboring fire departments free, harmless, and indemnified from any claim relating in any way to forced emergency entry damage or delayed access. 506.5 Cost. The cost of purchasing and installing, along with any cost associated with implementation of the program at a specific property, will be borne by the responsible party. 506.6 Regulations. The Fire Department shall create administrative guidelines and regulations governing placement and approval of KnoxBoxes®, the keeping and use of KnoxBox® keys, and KnoxBox® access. Any administrative guidelines and regulations imposing an obligation or duty upon a building, property, and/or responsible party shall have the force and effect of law as if fully set forth in this Section 506. 506.7 Definitions. As used in this section: Commercial building. A building protected by an automatic fire suppression and/or standpipe system or protected by an automatic fire alarm system (automatic dialer, central station, external audible/visual alarm), but does not include owner-occupied freestanding residential homes, government buildings, or multi-family apartment buildings with units that have direct outdoor access doors and individual addresses. Key. Any device that functions as a means to afford access and/or to unlock that which secures or controls entrance to a building, property, or other location, including but not limited to a standard key, an electronic card, a key fob, or a code. KnoxBox®. A secure device with a lock operable only by a fire department master key, and containing building entry keys and other keys that may be required for access in an emergency. The City requires a KnoxBox® type of key box, unless a fire marshal bulletin authorizes a different type, for uniformity, security, access, and long-term durability (see Chapter 5). Responsible party. The property owner of a building or property that is subject to this Section 506. In the event that the owner is a corporate entity, a property manager, business manager, or other individual responsible for the daily and legal operations of the business or enterprise on the property may be cited by the fire code official as the "responsible party" under this section. 506.8 Applicability. This section shall not apply to owner-occupied one and two family dwellings. However, any dwelling and any building or property may participate on a voluntary basis by purchasing a KnoxBox® key box independently. Section 507.5.1 shall be amended to read as follows: 507.5.1. Where required. Where a portion of the facility or building hereafter constructed or moved into or within the city is more than 400 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the fire code official. Exceptions: 1. For Group R-3 and Group U occupancies, the distance requirement shall be 600 feet. 2. For buildings equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the distance requirement shall be 600 feet. Fire hydrants shall be located not closer than 50 feet and not more than 100 feet from a Fire Department connection or standpipe connection, unless a different distance is approved by the fire code official. Hydrants shall be in-service and accessible, as prescribed by the fire code official, before construction and/or alterations begin as follows: a. For all residential Group R buildings or complexes; and b. For all other use groups, except that the fire code official may modify the requirements for in- service hydrants and access thereto for use groups other than residential when circumstances make such requirements impossible or impractical. Section 507.5.3(4) shall be added to read as follows: 4. For additional regulations covering private water supply systems, see Chapter 20, Article III, Section 20-51et seq. of the Sterling Heights City Code. Section 507.5.4 shall be amended to read as follows: 507.5.4. Obstruction. 1. Posts, fences, vehicles, growth, trash, storage, and other materials or objects shall not be placed or kept near fire hydrants, Fire Department inlet connections, or fire protection system control valves in a manner that would prevent such equipment or fire hydrants from being immediately discernible or accessible. No person shall place objects or otherwise engage in activity which deters or hinders the Fire Department from gaining immediate access to fire protection equipment or fire hydrants. 2. No person shall obscure from view, damage, deface, obstruct, or restrict the access to any fire hydrant or any Fire Department connection for the pressurization of fire suppression systems, including fire hydrants and Fire Department connections that are located on public or private streets and access lanes or on private property. 3. If, upon the expiration of the time noted in a notice of violation, obstructions in violation of this section are not removed, the fire code official may proceed to remove the obstructions. Costs incurred in the performance of work necessary to remove the obstructions shall be paid from the general fund with the approval of the City Manager or the City Manager's designee, and the City Attorney shall institute appropriate action for the recovery of such costs. Section 507.5.4.1 shall be added to read as follows: 507.5.4.1. Access gates. When fire hydrants provide coverage for multiple sites and fences are erected that obstruct access from one site, the fire code official may require that access gates be installed in said fence to provide access to the hydrant from both sites. Section 507.5.5 shall be amended to read as follows: 507.5.5. Clear space around hydrants. A 5-foot clear space shall be maintained around the circumference of fire hydrants, except as otherwise required or approved by the fire code official. Section 507.5.7 shall be added to read as follows: 507.5.7. Unauthorized use of hydrants. No person shall use or operate any fire hydrant, intended for use of the Fire Department for fire suppression purposes, without a permit issued by the city. This section shall not apply to the use of hydrants by persons employed by, and authorized to make such use on behalf of the city. Section 605.5.3 shall be added to read as follows: 605.5.3. Multi-family dwellings. Stoves in new multi-family dwellings shall be electrically powered with SmartBurner® or substantially equivalent technology designed with a built-in thermostat that prevents the stovetop from reaching fire-causing temperatures; gas stoves and other fuel-fired stoves are prohibited. Section 606.1 shall be amended to read as follows: 606.1 General. Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code, and all Type I hood exhaust systems shall be cleaned, inspected, and maintained as required by the most current edition of NFPA 96 and all applicable Fire Department regulations. The alarm system for commercial kitchen exhaust hoods shall be connected to the fire alarm system if a fire alarm system is required for the building. Section 606.5 shall be added to read as follows: 606.5 Exterior smoke. Commercial kitchen exhaust systems shall minimize the expulsion of visible smoke into the atmosphere outside of the structures within which they are installed. Any system that does not prevent the transfer of grease-laden smoke onto a rooftop, neighboring property, or area accessible by the public shall be in violation of this subsection, and the owner or operator of such system shall be responsible for citations and corrective measures required by the fire code official. In such circumstances, the fire code official may order the cooking operations of the business shut down until a new system is installed, or the existing system is modified, and the fire code official is satisfied that the transfer of grease-laden smoke will no longer occur. Section 709 shall be added to read as follows: SECTION 709—MAINTENANCE 709.1 Maintenance. Notwithstanding any other provisions in this chapter, the required fire-resistance rating of fire-resistance-rated construction, including but not limited to walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings, and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems, shall be maintained. Such elements shall be visually inspected by the owner annually and properly repaired, restored, or replaced where damaged, altered, breached, or penetrated. Records of inspections and repairs shall be maintained and a certification of compliance shall be filed with the fire code official on the form and in the manner directed by Fire Department regulations. Where concealed, such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel, access door, ceiling tile, or similar movable entry to the space. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Penetrations through barrier walls must comply with the requirements of an approved testing agency, such as Underwriters Laboratories Inc. Section 710 shall be added to read as follows: SECTION 710—MULTI-UNIT DWELLINGS 710.1 Multi-unit dwellings. Condominium associations, landlords, and apartment building owners shall provide either (1) the draft stop certification required by Section 701.2 on an annual basis, or (2) proof of installation of fire/smoke barrier wall warning signs if the building was constructed prior to February 29, 2004 (the date of adoption of the 2003 Michigan Building Code). Such certification and warning signs shall be in the form directed by regulations promulgated by the Fire Department. Exception: The requirements of this subsection shall not apply to condominium buildings or apartment buildings consisting of freestanding dwellings or which contain attic area of less than 3,000 square feet. Chapter 8 shall be amended to adopt Chapter 8 of the edition of the International Fire Code that corresponds with the most recently adopted Michigan Building Code. Chapter 9 shall be amended to adopt Chapter 9 of the edition of the International Fire Code that corresponds with the most recently adopted Michigan Building Code, with the following local amendments: Section 901.2.2 shall be added to read as follows: 901.2.2. Required licenses and certifications. All fire protection systems shall be installed by a contractor/installer/technician licensed or certified for the particular type of system. Such licenses and/or certifications shall include: 1. State of Michigan Department of Licensing and Regulatory Affairs or the current regulatory and licensing body regulating applicable sections of Public Act 207 of 1941, and Public Act 144 of 1982, Michigan Compiled Laws, as amended. 2. State of Michigan Mechanical Contractor's License through the Department of Labor and Economic Opportunity. 3. Certification from the company/manufacturer whose equipment the installer/technician is authorized to install and/or service. Section 901.5.2 shall be added to read as follows: 901.5.2. Separate tests. For fire protection systems installed in buildings designed for multiple tenants/uses, and when the system is installed/extended as the tenant spaces are developed, the individual tenant space systems shall be tested independently of the main system components and a contractor's material and test certificate is required for each tenant space. Section 901.8 shall be amended to read as follows: 901.8. Removal of or tampering with equipment. It shall be unlawful for any person to obstruct, remove, tamper with, or otherwise disturb any fire hydrant, fire detection and alarm system, fire suppression system, or other fire appliance required by this code except for the purpose of extinguishing fire, training or testing purposes, recharging or making necessary repairs, or when approved by the fire code official. Whenever a fire appliance is removed as herein permitted, it shall be replaced or reinstalled as soon as the purpose for which it was removed has been accomplished. Defective and unapproved fire appliances or equipment shall be replaced or repaired as directed by the fire code official. Section 901.11 shall be added to read as follows: 901.11. Building map. A building map satisfactory to the fire code official shall be installed in a conspicuous location near the annunciator panel which depicts the fire riser room, utility rooms, pump room, roof access, gas shutoffs, and any other fire-related features required by the fire code official. Section 903.4.2 shall be amended to read as follows: 903.4.2. Alarms. Approved audible and visible devices shall be connected to every automatic sprinkler system. Such sprinkler water-flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Alarm devices shall be provided on the exterior of the building in an approved location. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system. This subsection shall be renumbered as 903.4.3 in the event the 2024 Michigan Building Code is adopted. Section 903.6 shall be amended to read as follows: 903.6. Where required in existing buildings and structures. Where an automatic sprinkler system is provided in existing buildings and structures, when a tenant space in a multi-tenant building is renovated, when a change of tenancy occurs, or when modifications or repairs are made, a monitored smoke alarm connected to an audio/visual device on the outside of the building and specific to that tenant space shall be installed. Exception: The fire code official may exempt a building from the requirement of this subsection if the nature of the suppression system or the construction of the building or structure renders the installation of a monitored smoke alarm with an outside audio/visual device impractical or impossible. Section 903.7 shall be added to read as follows: 903.7. New multi-tenant buildings. A separate water flow monitoring device notification shall be installed and maintained on the outside of new buildings in a location approved by the fire code official for each sprinkler zone. Section 903.8 shall be added to read as follows: 903.8. Annunciating panel. An annunciating panel and pull station shall be installed and maintained in a location near the front entrance door of the building in a location approved by the fire code official. Section 907.2.11.6 shall be amended to read as follows: 907.2.11.6 Power source. In new construction, required smoke alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms with integral strobes that are not equipped with battery back-up shall be connected to an emergency electrical system in accordance with Section 604. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection. In addition to the requirements of the Housing Law of Michigan, Public Act 167 of 1917 as amended by Public Act 64 of 2004, all residential multi-family properties shall utilize a 10-year lithium sealed battery for the battery backup of smoke alarms in all common areas, and all residential rental properties shall utilize a 10-year lithium sealed battery for the battery backup of smoke alarms in each dwelling unit. The term "residential rental properties" includes, but is not limited to, hotels, motels, bed and breakfast facilities, homes, and other residential spaces offered for use as short-term or long-term dwellings in exchange for payment or other forms of consideration. Exception: Smoke alarms are not required to be equipped with battery backup where they are connected to an emergency electrical system that complies with Section 604. Any reference in this subsection to Section 604 shall be deemed a reference to Section 1203 in the event the 2024 Michigan Building Code is adopted. Section 907.8.6 shall be added to read as follows: 907.8.6 Maintenance. It shall be the responsibility of the owner of any Group R (residential) occupancy, which is occupied by tenants, to maintain in an operative condition at all times all smoke alarm devices and systems required by this code. It shall also be the responsibility of the owner to certify in writing to the fire code official on or before July 1st of each year that the prescribed maintenance has been performed and that any defective smoke alarms have been repaired or replaced. This subsection shall be renumbered as 907.8.5 in the event the 2024 Michigan Building Code is adopted. Section 907.8.7 shall be added to read as follows: 907.8.7. Compliance dates. Owners of single family dwellings or a unit in a multiple family dwelling under individual ownership (condominium) shall comply with the provisions of this section upon resale or reoccupancy, whichever occurs first, in accordance with the provisions of this ordinance. Owners of multiple-family dwellings (three families or more) occupied by tenants shall comply with Section 907.8.8. This subsection shall be renumbered as 907.8.6 in the event the 2024 Michigan Building Code is adopted. Section 907.8.8 shall be added to read as follows: 907.8.8. Certification at change of occupancy. At every change of occupants of every dwelling unit occasioned by or incidental to a sale, lease, or sublease of said unit, it shall be the duty of the grantor thereof (the seller, lessor, or sublessor as the case may be) to certify before occupancy to the new occupant that all smoke alarms as required by this ordinance or other applicable laws are installed and in proper working condition. Upon the resale of any single-family or multiple-family dwelling, the fire code official of the City of Sterling Heights shall be provided certification by the seller that all smoke alarms are installed in accordance with the applicable codes and ordinances and are in proper working condition. This subsection shall be renumbered as 907.8.7 in the event the 2024 Michigan Building Code is adopted. Section 912.2.1.1 shall be added to read as follows: 912.2.1.1 Fire Department connection signal. All Fire Department connections shall be indicated by an audible and visible alarm device activated by the water-flow switch, which device shall be located in the immediate area of the Fire Department connection and at a height that will permit constant visibility. Section 912.4 shall be amended to read as follows: 912.4. Access. Immediate access to Fire Department connections shall be maintained at all times and without obstruction by fences, bushes, trees, walls, or any other object for a minimum of 3 feet on either lateral side and an unobstructed approach with a minimum width of 10 feet, unless a wider approach is required by the fire code official. Section 916 of the 2024 edition of the International Fire Code is hereby adopted verbatim and incorporated by reference herein. Chapter 10 shall be amended to adopt Chapter 10 of the edition of the International Fire Code that corresponds with the most recently adopted Michigan Building Code. Section 1207.12 shall be added to read as follows: 1207.12 NFPA standards. Notwithstanding any other provisions in this code, battery safety standards enacted by the NFPA shall apply to all raw material storage, assembly, and production relating to batteries and electrical energy storage systems. The fire code official may enact or require additional safety regulations tailored to mitigate and address the hazards presented by batteries and electrical energy storage systems throughout their lifecycle, from raw materials and battery production through storage, use, and end of life [image omitted; see the official code] Section 3103.1 shall be amended to read as follows: 3103.1 General. Tents and membrane structures used for temporary periods shall comply with this section and Section 3107. Other temporary structures erected for a period of 180 days or less shall comply with the Michigan Building Code. Section 3307.1 shall be amended to read as follows: 3307.1. Required access. Approved vehicle access for fire fighting shall be provided to all construction or demolition sites. Vehicle access shall be provided to within 100 feet of temporary or permanent Fire Department connections and to within 20 feet of fire hydrants. Vehicle access shall be provided by either temporary or permanent roads, capable of supporting vehicle loading under all weather conditions. Access roads shall be provided by the contractor or property owner. Section 3404.7 shall be added to read as follows: 3404.7. Incompatible product storage. Products incompatible with the storage of tires, as determined by the fire code official based on combustibility, fire risk, and burn duration, shall not be stored with tires within the same fire-rated area without the installation of a 2-hour (minimum) fire separation. Section 4106.1 shall be amended to read as follows: 4106.1 General. Mobile food preparation vehicles shall comply with NFPA 96 and this section. Indoor use of mobile food preparation vehicles is prohibited unless approved by the fire code official. Section 4106.6 shall be added to read as follows: 4106.6 Additional requirements. Generators that power a mobile food preparation vehicle or trailer shall be placed a minimum of 10 feet from its own, and any other, mobile food preparation vehicle or trailer, and not in locations where the public is invited to be, unless the generator is built into the mobile food preparation vehicle as part of the vehicle's or trailer's original design or professionally installed as a modification specifically designed for that vehicle or trailer. Users of mobile food preparation vehicles and trailers shall ensure that no carbon monoxide is directed at, or escapes into, any mobile food preparation vehicle or trailer, or immediate perimeter thereof where the public or employees may reasonably be expected to enter or stay. Every mobile food preparation vehicle or trailer shall be equipped with, or monitored by, carbon monoxide detectors within the public spaces identified herein. Generators shall not be fueled using unapproved fuel containers. Section 5301.3 shall be added to read as follows: 5301.3 Nitrous oxide. Notwithstanding any provision to the contrary in this code, the possession and/or sale of nitrous oxide is prohibited without a permit approved by the fire code official. Section 5601.1 shall be amended to read as follows: 5601.1 Scope. The provisions of this chapter shall govern the possession, manufacture, storage, handling, sale, and use of explosives, explosive materials, fireworks, and small arms ammunition. Article V of Chapter 20 of the City Code shall supersede and preempt the provisions of this chapter to the extent that any of their respective provisions are in conflict regarding fireworks. Section D102.1.1 of Appendix D shall be added to read as follows: D102.1.1 No corner connections. Buildings or portions of buildings hereafter constructed shall not be constructed with an "L-Shape" or "U-Shape" design such that any corners of otherwise separate buildings are connected in a manner that eliminates or forecloses fire apparatus access between them. All buildings shall be separated by a minimum of 10 feet. [image omitted; see the official code] Examples of prohibited designs: Section D103.6 of Appendix D shall be amended to read as follows: D103.6. Signs. Where required by the fire code official, fire apparatus access roads shall be marked with permanent NO PARKING - FIRE LANE signs substantially complying with Figure D103.6. Signs shall have a minimum dimension of 12 inches wide by 18 inches high and have red letters on a white reflective background. Signs shall be posted on one or both sides of the fire apparatus road as required by Section D103.6.1 or D103.6.2. Section D103.6.1 of Appendix D shall be amended to read as follows: D103.6.1. Roads 20 to 26 feet in width. Fire apparatus access roads 20 to 26 feet wide shall be posted on one or both sides, as directed by the fire code official, as a fire lane. Section D105.5 of Appendix D shall be added to read as follows: D105.5. Rescue from a balcony. An aerial fire apparatus access road approved by the fire code official for the purpose of victim rescue with an aerial fire apparatus, and which must provide access to every balcony, is required for any structure with a balcony over 30 feet in height from the lowest level of firefighter access (lowest point of grade) for any residential group structure R-1, R-2, R-3, or R-4, and for any mixed use structure, with a balcony that is accessible from inside a unit. (1973 Code, § 13-23; Ord. No. 185-A, § 2, 2-7-84; Ord. No. 185-B, § 2, 6-16-86; Ord. No. 185-C, § 1, 11- 5-86; Ord. No. 268, § 2, 7-5-88; Ord. No. 287, § 2, 2-19-91; Ord. No. 287-A, §§ 1, 2, 11-6-91; Ord. No. 310, § 1, 3-6-94; Ord. No. 279-A, § 6, 7-2-96; Ord. No. 336, § 1, 9-1-98; Ord. No. 361, §§ 2,3,4, 5-7-02; Ord. No. 366, § 1, 11-6-02; Ord. No. 374, § 1, 12-21-04; Ord. No. 393, § 2, 1-2-08; Ord. No. 413, §§ 2 - 16, 5-17-11; Ord. No. 429, § 1, 7-16-13; Ord. No. 443, § 1, 1-5-16; Ord. No. 452, § 3, 6-20-17; Ord. No. 455, § 2, 12-19-17; Ord. No. 504, § 2, 7-1-25)

Ask a question about Sterling Heights law

Corpus searches the Sterling Heights sections it holds and shows the ones that match, with their citations. Free, no sign-in.