§ 41-75 — Local discharge limits
Code of Ordinances of the City of Warren, Michigan (Supp. No. 102: codified through Ordinance No. 80-840, adopted October 28, 2025) · Warren City Code § 41-75
Corpus is an independent public-information project, not the official City of Warren website. Stable reference: corpuslaw.us/code/fd1ceb28-f40c-4dcd-a226-55b5b0713f2a
Sec. 41-75. - Local discharge limits.
(a) Effluent limits. Unless, a written authorization from the city is obtained pursuant to subsection (e) of this section, an industrial user shall not discharge wastewater that exceeds the following concentrations: Arsenic | 0.33 mg/l Beryllium | 0.005 mg/l Cadmium | 0.29 mg/l Chromium (Total) | 7.0 mg/l Copper | 4.5 mg/l Lead | 0.6 mg/l Lithium | 0.83 mg/l Mercury | See subsection (b) of this section Nickel | 4.1 mg/l Selenium | 0.21 mg/l Silver | 0.82 mg/l Thallium | 0.54 mg/l Zinc | 4.2 mg/l BOD (Biological Oxygen Demand) | 2100.0 mg/l TSS (Total Suspended Solids) | 1450.0 mg/l Phosphorus | 75.0 mg/l Ammonia-N or Total K Kjeldahl (TKN)* | 200.0 mg/l * If significant organic nitrogen is or may be present, Ammonia-N may be expressed as Total Kjeldahl Nitrogen (TKN). (b) Mercury limits. Any mercury discharge at detectable levels is a violation of this article. The mercury discharge level is calculated by EPA Method 245.1 or an EPA-approved equivalent. The PQL shall be no higher than 0.0002 mg/l, unless a higher quantification level is appropriate because of demonstrated sample matrix interference. (c) Effluent limits in grab sample. Unless a written authorization from the city is obtained pursuant to subsection (e) of this section, an industrial user shall not discharge wastewater that exceeds the following concentrations in any grab sample: Chromium (Hexavalent) | 0.5 mg/l Cyanide (Available) | 0.5 mg/l Cyanide (Total) | 1.3 mg/l Perfluorooctanesulfonic acid (PFOS) | 0.000192 mg/l Total Phenolics | 0.67 mg/l Petroleum Based Fats, Oil and Grease | 150.0 mg/l Total Fats, Oil and Grease | 900.0 mg/l (d) New limits. If the superintendent determines that an industrial user is contributing or proposes to contribute any substances to the POTW in a quality, quantity, or location that the superintendent determines is reasonably likely to adversely affect the POTW or the receiving stream, the superintendent may develop and enforce effluent limits that are specifically applicable to that substance, industrial user, or both. (e) Specific alternative limit permits. (1) Authority to grant. Subject to the requirements and restrictions listed in this subsection (e), the superintendent, at his sole discretion, may grant a specific alternative limit (SAL) or multiple specific alternative limits to an industrial user in an industrial pretreatment permit that allows discharges to the POTW that are different than the effluent limits listed in (a) and (c) of this section (SAL permit). (2) Constituent. The superintendent shall only grant SAL permits for BOD, TSS, Phosphorus, and Ammonia-N/ Total K Kjeldahl (TKN) (3) Maximum allowable headworks and industrial loadings. In determining a SAL, the superintendent may allocate a share of the maximum allowable headworks loading and maximum allowable industrial loading for BOD, TSS, Phosphorus, and Ammonia-N among one or more industrial users in amounts and on terms and conditions the superintendent deems appropriate and are in accordance with SAL procedures approved by the MDEQ. a. The POTW plant headworks loadings shall not exceed the following levels: BOD (Biological Oxygen Demand) | 48,000 lb/day TSS (Total Suspended Solids) | 43,500 lb/day Phosphorus | 1,030 lb/day Ammonia-N | 4,500 lb/day b. The POTW plant industrial loadings shall not exceed the following levels: BOD (Biological Oxygen Demand) | 27,500 lb/day TSS (Total Suspended Solids) | 18,350 lb/day Phosphorus | 402 lb/day Ammonia-N | 1,510 lb/day (4) Fundamentally different factor variance. The superintendent shall not grant a SAL that is less stringent than the effluent limits listed in (a) and (c) of this section, unless the industrial user qualifies for a fundamentally different factor variance that allows the user to exceed the applicable effluent limits. If the superintendent grants a variance, the SAL shall not exceed the limits provided in the variance. (5) Acknowledgement and acceptance. Before the superintendent grants a SAL permit, the industrial user shall sign an acknowledgement and acceptance of both the provisions of this subsection (e) and the specific SAL permit conditions or provisions. (6) Additional conditions or provisions. The superintendent may include in a SAL permit any conditions or provisions that comply with this article and any other applicable city, state, or federal laws or regulations. (7) Compensatory charge. The superintendent may include in a SAL permit a provision requiring that the industrial user pay a compensatory charge to the city. (8) No additional rights created. The SAL permit does not create any rights or future expectations beyond the limited scope of the express language of the SAL permit. (9) Termination or modification. At any time after granting the SAL permit, the superintendent may terminate or modify it without the industrial user's consent. (10) Violation. Any violation of a SAL permit provision is a violation of this article. _____
(Ord. No. 80-417, § 1, 9-8-92; Ord. No. 80-640, § 1, 11-14-06; Ord. No. 80-744, § 3, 6-14-16; Ord. No. 80-810, § 1, 9-12-23)
Ask a question about Warren law
Corpus searches the Warren sections it holds and shows the ones that match, with their citations. Free, no sign-in.