For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 21.301.24 — EXTERIOR MATERIALS AND FINISH

Bloomington, Minnesota City Code · Bloomington City Code § 21.301.24

Corpus is an independent public-information project, not the official City of Bloomington website. Stable reference: corpuslaw.us/code/bb3dd206-5d5f-41d5-9bf3-f94ab2618387

§ 21.301.24 EXTERIOR MATERIALS AND FINISH.

(a) Purpose. The City Council finds that it is necessary to regulate the exterior finish and appearance of all principal and accessory buildings and structures that are erected in all of the primary nonresidential zoning districts in the city in order to ensure the consistency in quality, compatibility and character of buildings within comparable zoning districts. The regulation of exterior materials and building construction assures consistent provision of both a high level of structural durability relative to impacts from natural and human-made forces over time and a safe environment for those occupants, equipment and goods within the structure. The provision of a quality exterior finish compliments the building construction by reducing maintenance needs, providing a surface more resistant to damage, assisting in maintaining structure and property value over a longer period, contributing substantially to the compatibility and character of its neighborhood. A quality exterior finish also provides for improved health, safety and welfare of occupants and enclosed goods or equipment by providing increased protection through durability, strength, security, damage resistance and stability. (b) Applicability. The regulations contained in this section apply to all principal and accessory buildings and their additions in all zoning districts, except that residential principal and accessory buildings and their additions in the R-1, RS-1, R-1A, R-3, R-4, RM-15, RM-24, and SC zoning districts are exempt from this section. (c) Definitions. When used in this section, the following words and terms have the following meanings, unless the context clearly indicates otherwise. Other words and terms not defined in this section may be defined in § 21.601. ARCHITECTURAL CONCRETE. Any integrally-colored, architecturally patterned precast concrete panel or cast-in-place concrete having an exposed aggregate, light sandblast, acid etch, form liner, natural stone veneer, brick face and/or cast stone type textured finish (excluding a raked or vertical striation finish). ARCHITECTURAL CONCRETE does not include smooth, unfinished, or painted precast concrete panels or cast-in-place concrete. ARCHITECTURAL CONCRETE MASONRY UNITS (ACMUs). An integrally-colored concrete masonry unit on which the face has been shaped, ground, glazed, scored, split or otherwise processed to produce a unit with specific aesthetic texture or burnished block face. ARCHITECTURAL CONCRETE MASONRY UNITS do not include smooth, unfinished or painted concrete masonry units. ARCHITECTURAL METAL PANEL SYSTEMS. A set of metal panels working together to create a building's exterior wall as part of the building envelope. Metal panels used in an ARCHITECTURAL METAL PANEL SYSTEM can include single skin metal panels, metal composite material (MCM) metal panels and insulated metal panels. All panels must have a minimum 30-year manufacturer's warranty and an appropriate gauge as approved by the Planning Manager. (d) Multiple-family residential, commercial, office, mixed use and transitional industrial zoning districts. The following regulations apply to all principal and accessory buildings and their additions in the RM-50, RM-100, B-1, B-2, B-4, C-1, C-2, C-3, C-4, C-5, CR-1, FD-2, CS-0.5, CS-1, CO-1, RO-24, HX-R, CX-2, LX, IT, and TI zoning districts. (1) Exterior wall finish. Exterior wall surfaces of all buildings, excluding those portions of foundation walls extending normally above finished grade, must be faced with any of the primary exterior materials listed in the table below, provided they meet the following standards and all other applicable requirements of the city code: Primary Exterior Materials for Principal and Accessory Buildings and Their Additions in RM-50, RM-100, B-1, B-2, B-4, C-1, C-2, C-3, C-4, C-5, CR-1, FD-2, CS-0.5, CS-1, CO-1, RO-24, HX-R, CX-2, LX, IT, and TI Zoning Districts Architectural concreteArchitectural concrete masonry units (ACMUs) - embossed with a brick running bond pattern and 4 inch tall masonry units onlyArchitectural metal panelsBrickExterior cement plaster (stucco)GlassNatural stoneEquivalent material or better - as approved by the Planning Manager only Table Notes:1) Except for brick, metal, or stucco, all color must be integral to the exterior wall finish material.2) Any coating used on brick, metal, or stucco must be appropriate for that purpose and not damage the exterior wall finish material or reduce or void the exterior wall finish material warranty.3) A minimum of 65 percent of each building elevation must be primary exterior materials. (2) Secondary materials. An exterior wall surface of a building elevation may include secondary exterior materials listed in the table below, provided they meet the following standards and all other applicable requirements of the city code: Secondary Exterior Materials for Principal and Accessory Buildings and Their Additions in RM-50, RM-100, B-1, B-2, B-4, C-1, C-2, C-3, C-4, C-5, CR-1, FD-2, CS-0.5, CS-1, CO-1, RO-24, HX-R, CX-2, LX, IT, and TI Zoning Districts Architectural concrete masonry units (ACMUs)Engineered wood productsExterior insulation finish system (EIFS) or synthetic stuccoFiber-cement exterior sidingManufactured stoneOrnamental metalPhenolic panelsThin brick veneerWoodEquivalent material or better - as approved by the Planning Manager only Table Notes:1) Except for EIFS or synthetic stucco, ornamental metal, or wood all color must be integral to the exterior wall finish material.2) Any coating used on EIFS or synthetic stucco, ornamental metal, or wood must be appropriate for that purpose and not damage the exterior wall finish material or reduce or void the exterior wall finish material warranty.3) All approved secondary exterior materials combined must not exceed 35 percent of each building elevation.4) EIFS or synthetic stucco must be installed with a continuous mineral or stone wool insulation assembly. Expanded polystyrene (EPS) foam or insulation board materials are not permitted in any EIFS or synthetic stucco installation. Any EIFS or synthetic stucco installation must be at least 18 feet above grade to a maximum height of 40 feet above grade. EIFS or synthetic stucco must be installed and maintained to the manufacturer's specifications. The city may require an inspection and subsequent report of the EIFS installation upon request. EIFS or synthetic stucco is not permitted on an exterior wall surface of a hospital use building. (3) Canopies and awnings. The exterior wall surface of a building elevation may be covered by canopies and/or awnings intended to provide aesthetic embellishment, shade or weather protection. Exterior wall surface materials covered by canopies or awnings must meet the applicable requirements of this section and, depending on the wall surface material, count as secondary materials. Canopies and awnings must meet all applicable building and fire code requirements to ensure proper installation. (e) Industrial zoning districts. The following regulations apply to all principal and accessory buildings and their additions in the I-1, I-2, I-3, and IP zoning districts. (1) Exterior wall finish. Exterior wall surfaces of all buildings, excluding those portions of foundation walls extending normally above finished grade, must be faced with any of the primary exterior materials listed in the table below, provided they meet the following standards and all other applicable requirements of the city code: Primary Exterior Materials for Principal and Accessory Buildings and Their Additions in I-1, I-2, I-3, and IP Zoning Districts Architectural concreteArchitectural concrete masonry units (ACMUs)Architectural metal panelsBrickExterior cement plaster (stucco)GlassNatural stoneRaked or vertical striation finish precast concrete panelsEquivalent material or better - as approved by the Planning Manager only Table Notes:1) Except for brick, metal, or stucco, all color must be integral to the exterior wall finish material.2) Any coating used on brick, metal, or stucco must be appropriate for that purpose and not damage the exterior wall finish material or reduce or void the exterior wall finish material warranty.3) A minimum of 65 percent of each building elevation must be primary exterior materials. (A) Buildings which do not currently comply with the exterior wall finish materials regulated by this section may be expanded using identical exterior wall finish materials with the approval of the Planning Manager, provided that: (i) More than 50% of the total exterior wall surface area of the existing building, excluding secondary materials as listed in subsection(e)(2) below, does not comply with the exterior wall finish materials regulated by this section; (ii) The noncomplying exterior wall finish materials are used in compliance with the State Building Code; and (iii) The total floor area of the addition does not exceed 50% of the total floor area of the building existing on the effective date of this section. (2) Secondary materials. An exterior wall surface of a building elevation may include secondary exterior materials listed in the table below, provided they meet the following standards and all other applicable requirements of the city code: Secondary Exterior Materials for Principal and Accessory Buildings and Their Additions in I-1, I-2, I-3, and IP Zoning Districts Architectural concrete masonry units (ACMUs)Engineered wood productsExterior insulation finish system (EIFS) or synthetic stuccoFiber-cement exterior sidingManufactured stoneOrnamental metalPhenolic panelsThin brick veneerWoodEquivalent material or better - as approved by the Planning Manager only Table Notes:1) Except for EIFS or synthetic stucco, ornamental metal, or wood all color must be integral to the exterior wall finish material.2) Any coating used on EIFS or synthetic stucco, ornamental metal, or wood must be appropriate for that purpose and not damage the exterior wall finish material or reduce or void the exterior wall finish material warranty.3) All approved secondary exterior materials combined must not exceed 35 percent of each building elevation.4) EIFS or synthetic stucco must be installed with a continuous mineral or stone wool insulation assembly. Expanded polystyrene (EPS) foam or insulation board materials are not permitted in any EIFS or synthetic stucco installation. Any EIFS or synthetic stucco installation must be at least 18 feet above grade to a maximum height of 40 feet above grade. EIFS or synthetic stucco must be installed and maintained to the manufacturer's specifications. The city may require an inspection and subsequent report of the EIFS installation upon request. EIFS or synthetic stucco is not permitted on an exterior wall surface of a hospital use building. (3) Canopies and awnings. The exterior wall surface of a building elevation may be covered by canopies and/or awnings intended to provide aesthetic embellishment, shade or weather protection. Exterior wall surface materials covered by canopies or awnings must meet the applicable requirements of this section and, depending on the wall surface material, count as secondary materials. Canopies and awnings must meet all applicable building and fire code requirements to ensure proper installation. (f) Exterior building maintenance. The International Property Maintenance Code is adopted by the city within this city code and enforced and administered by the city. Buildings and other structures which have been so poorly maintained can cause their physical condition and appearance to create inconsistency in the quality, compatibility and character of buildings within comparable zoning districts. To ensure quality exterior finishes: (1) No part of any exterior surface will have deterioration, holes, breaks, gaps, loose or rotting boards or timbers. (2) Every exterior surface, which has had a surface finish such as paint applied, must be maintained to avoid noticeable deterioration of the finish. No wall or other exterior surface will have peeling, cracked, chipped or otherwise deteriorated surface finish on any one exterior wall surface. (3) All cornices, moldings, lintels, sills, bay or dormer windows, and similar projections must be kept in good repair and free from cracks and defects which make them hazardous or unsightly. (4) Decks, canopies, awnings, porches, chimneys, antennae, air vents, and other similar projections must be structurally sound and in good repair. Such projections must be secured properly, where applicable, to an exterior wall or exterior roof. (g) Murals. Murals approved according to the standards and procedures in § 21.301.25 are permitted and exempt from the requirements of this section. (h) Previous coating. All exterior wall surfaces and secondary materials that were coated prior to the effective date of this section or were allowed to be coated by reason of the granting of development approval, administrative approval or a variance may be maintained, to include sealing and recoating, in a manner appropriate to that wall finish material or trim and consistent with that existing surface treatment or any prior approval by the issuing authority. (i) Exceptions to construction requirements. When a building is sought to be erected in any zoning district by a governmental agency for the purpose of storage of chemical road materials, to protect against any adverse impact which might be caused by such outside storage, the construction requirements of the zoning district in which the building is to be located need not be complied with so long as the proposed building has been approved by the City entity with decision- making authority to approve the site plan or development application as: (1) Necessary for environmental protection; (2) Not contrary to the purposes of the zoning code and the purposes of the zoning district in which the building is to be erected; (3) Not having an appearance which will adversely affect adjacent uses; and (4) Having the building sufficiently separated by distance or screening from adjacent residentially zoned or used land so that existing homes will not be depreciated in value and so that there will be no deterrence to development of vacant land. (Ord. 2024-28, passed 11-18-2024; Ord. 2025-10, passed 6-2-2025; Ord. 2026-05, passed 3-23- 2026)

Ask a question about Bloomington law

Corpus searches the Bloomington sections it holds and shows the ones that match, with their citations. Free, no sign-in.