§ 10-3-2 — PRELIMINARY PLAT
Lakeville, Minnesota Code of Ordinances (2026 S-14, code current through Ord. 1122, passed 4-20-2026) · Lakeville Code of Ordinances § 10-3-2
Corpus is an independent public-information project, not the official City of Lakeville website. Stable reference: corpuslaw.us/code/3c8a9f97-b8e8-44ae-a98a-4704e7805dfa
10-3-2: PRELIMINARY PLAT:
The subdivider shall prepare and submit a preliminary plat, together with any necessary supplementary information, preliminary utility plan and preliminary grading plan. The plans shall contain the information set forth in the subsections that follow: A. Proof Of Ownership: 1. Current title commitment or current title opinion for abstract property and a certificate of title for registered property (torrens). 2. Written authorization from current owner, if current owner is not making application for platting. B. Certificate Of Survey: A current certificate of survey, prepared and signed by a Minnesota licensed land surveyor, depicting the following: 1. Graphic scale of drawing (engineering scale only, not less than 1 inch equals 100 feet). 2. North arrow. 3. Date of survey. 4. Existing legal description of the parcel of land to be platted. 5. Existing parcel boundaries shown with survey measurement data matching the existing legal description of the parcel of land to be platted. 6. Area in square feet and acres of the outside boundary of the parcel of land to be platted. 7. Existing site improvements inside the outside boundaries and fifty feet (50') outside the outside boundaries of the parcel of land to be platted. 8. All encroachments along the outside boundary of the parcel of land to be platted. 9. Easements of record (referenced in the current title commitment, current title opinion or certificate of title). (Ord. 673, sec. 1, 7-17-2000) 10. Basins, lakes, rivers, streams, creeks, wetlands, and other waterways bordering on or running through the parcel of land and delineation of any or portions of any wetlands within the subject property to be platted. The ordinary high water elevation and the 100-year flood elevation shall be shown where applicable, if available from the city or the DNR. (Ord. 866, sec. 5, 5-17-2010) 11. Location, right of way widths and names of public streets or other public ways, showing type, width and condition of improvements, if any, which pass through and/or are adjacent to the parcel of land being platted. 12. Location, right of way widths and names of railroads, if any, which pass through and/or are adjacent to the parcel of land being platted. 13. Identify registered lands (torrens) within the outside boundaries of the parcel of land being platted. 14. Identify all gaps and overlaps of the property being platted. 15. The outside boundary of the property being platted must be clearly marked with survey monumentation. C. Preliminary Plat: 1. General Requirements: a. The current certificate of survey must be used as a base for the preparation of the preliminary plat. b. Proposed name of subdivision; names shall not duplicate or too closely resemble names of existing platted subdivisions within Dakota County. Proposed names must be verified with the Dakota County recorder. c. Graphic scale of drawing (engineering scale only, not less than 1 inch equals 100 feet). d. Date of preparation. e. North arrow. f. Location of boundary lines in relation to a known section, quarter section or quarter-quarter section lines comprising a legal description of the property. g. Name and address of the property owner(s). h. Name and address of the subdivider. i. Name and address of the designer (and their Minnesota license number), if any, of the proposed plat. j. Existing zoning classifications for lands within and abutting the proposed plat, including shoreland zoning boundaries. k. Boundary lines of adjoining unsubdivided or subdivided land, within three hundred fifty feet (350'), including all contiguous land owned or controlled by the subdivider. l. In plats where public water and sewer are not available, the subdivider shall file a report prepared by a certified soils evaluator or registered civil engineer on the feasibility of individual on site sewer and water systems on each lot, and shall include soils boring analysis and percolation tests to verify conclusions. 2. Proposed Design Features: a. Layout of proposed streets showing the right of way widths, centerline gradients, typical street sections, and proposed names of streets in conformance with the county uniform street naming and addressing system. The name of any street heretofore used in the city or its environs shall not be used unless the proposed street is a logical extension of an already named street, in which event the same name shall be used. b. Locations and widths of proposed alleys and pedestrianways. c. Location, dimensions and purpose of all easements. d. Layout, numbers, lot areas and preliminary dimensions of lots and blocks. e. Minimum front and side street building setback lines. f. When lots are located on a curve, the width of the lot at the building setback line. g. Areas, other than streets, alleys, pedestrianways, and utility easements, intended to be dedicated or reserved for public use, including the size of such area or areas in acres. 3. Supplementary Information: a. Any or all of the supplementary information requirements set forth in this subsection shall be submitted when deemed necessary by the city staff, consultants, advisory bodies and/or city council. b. Proposed protective covenants. (Ord. 673, sec. 1, 7-17-2000) c. An accurate soil survey of the subdivision prepared by a registered soils engineer. (Ord. 866, sec. 6, 5-17-2010) d. A tree preservation plan and tree replacement plan as required by section 11-21-11 of the Zoning Ordinance. e. Statement of the proposed use of lots stating the type of buildings with number of proposed dwelling units or type of business or industry, so as to reveal the effect of the development on traffic, fire hazards and congestion of population and compliance with the provisions of the zoning ordinance including submission of the following for commercial and industrial developments: (1) Proposed building floor plans. (2) Proposed architectural elevations including types of exterior materials. (3) Comprehensive sign plan illustrating the number, location, area and height of all proposed signs. (Ord. 888, 2-21-2012) f. If any zoning changes are contemplated, the proposed zoning plan for the areas, including dimensions, shall be shown. Such proposed zoning plan shall be for information only and shall not vest any right in the applicant. g. The subdivider shall be required to submit a sketch plan of adjacent properties so as to show the possible relationships between the proposed subdivision and future subdivisions. All subdivisions shall be required to relate well with existing or potential adjacent subdivisions. h. Where structures are to be placed on large or excessively deep lots that are subject to potential replat, the preliminary plat shall indicate a logical way in which the lots could possibly be resubdivided in the future. i. When the city has agreed to install improvements in a development, the developer will be required to furnish a financial security satisfactory to the city. j. A comprehensive screening plan which identifies all proposed buffering and screening in both plan and sectional view. k. Where irregular shaped lots have been proposed, house plans shall be submitted which demonstrate such lots to be buildable and the resulting structure compatible in size and character to the surrounding area. l. Such other information as may be required. (Ord. 673, sec. 1, 7-17-2000) m. The preliminary plat shall include a table with the following information: (1) Gross acres. (2) Net developable acres. (3) Comprehensive plan land use designation. (4) Existing and/or proposed zoning. (5) Gross unit density. (6) Net unit density. (7) Acres of right of way. (8) Acres of wetland. (9) Acreage of each outlot. n. Site dimension plan. (Ord. 866, sec. 8, 5-17-2010) D. Preliminary Grading Plan: The developer shall submit a preliminary grading, drainage and erosion control plan utilizing a copy of the current certificate of survey as a base for the site in question, prepared and signed by a Minnesota licensed engineer, depicting the following information: 1. North arrow and date of preparation. 2. Graphic scale (engineering scale only, not less than 1 inch equals 50 feet). 3. Lot and block numbers, house pad location, home style and proposed building pad elevations at garage slab and lowest floor for each lot. (Ord. 673, sec. 1, 7-17-2000) 4. Drainage plan, with a narrative, including the configuration of drainage areas and calculations. The locations of proposed infiltration basins must include soil borings and infiltration tests. (Ord. 866, sec. 9, 5-17-2010) 5. Location of all natural features on the tract. Natural features are considered to include, but are not limited to, the following: tree lines, wetlands, ponds, lakes, streams, drainage channels, bluffs, steep slopes, etc. (Ord. 673, sec. 1, 7-17-2000) 6. Location of all existing storm sewer facilities, including pipes, manholes, catch basins, stormwater basins, swales, and drainage channels within one hundred fifty feet (150') of the tract. Existing pipe grades, rim and invert elevations, and normal and high water elevations must be included. (Ord. 866, sec. 10, 5-17-2010) 7. If plat is located within or adjacent to a 100-year floodplain, flood elevations and locations must be clearly shown on the plan. 8. Spot elevations at drainage breakpoints and directional arrows indicating site, swale and lot drainage. (Ord. 673, sec. 1, 7-17-2000) 9. Locations, grades, rim and invert elevations of all storm sewer facilities, including stormwater basins, proposed to serve the tract. (Ord. 866, sec. 11, 5-17-2010) 10. Locations and elevations of all street high and low points. 11. Street grades shown, with a maximum permissible grade of ten percent (10%) and a minimum of five-tenths percent (0.5%). 12. Phasing of grading. 13. The location of all oversize nontypical easements. (Ord. 673, sec. 1, 7-17-2000) 14. A stormwater pollution prevention plan (SWPPP) including all soil erosion and sediment control measures to be incorporated during and after construction must be shown. Locations and standard detail plates for each measure must be included on the plan. (Ord. 866, sec. 12, 5-17-2010) 15. All revegetation measures proposed for the tract, including seed and mulch types and application rates must be included on the plan. 16. Tree preservation plan, prepared in accordance with current city standards and specifications. 17. Existing contours at two foot (2') intervals shown as dashed lines (may be prepared by a Minnesota licensed surveyor). Existing contours shall extend one hundred fifty feet (150') outside of the tract. 18. Proposed grade elevations at two foot (2') intervals shown as solid lines. (Ord. 673, sec. 1, 7-17-2000) 19. Appropriate wetland permits in conformance with the wetland conservation act, the city's wetland management plan and buffer requirements. (Ord. 866, sec. 13, 5-17-2010) 20. All modular block retaining walls to be constructed as part of the subdivision grading plan must meet MN/DOT requirements. A registered engineer must design any retaining wall that has a combined height greater than four feet (4'). The building official must approve the retaining wall plans and each retaining wall is subject to issuance of a separate building permit. (Ord. 866, sec. 14, 5-17-2010) E. Preliminary Utility Plan: Preliminary utility plan, prepared and signed by a Minnesota licensed engineer, depicting the following information: 1. Easements: Location, dimension and purpose of all easements. 2. Underground Facilities: Location and size of existing sewers, water mains, culverts, or other underground facilities within the tract and to a distance of one hundred fifty feet (150') beyond the tract. Such data as grades, invert elevations, and location of catch basins, manholes and hydrants shall also be shown. 3. Water Supply: Water mains shall be provided to serve the subdivision by extension of an existing community system wherever feasible. Service connections shall be stubbed into the property line and all necessary fire hydrants shall also be provided. Extensions of the public water supply system shall be designed so as to provide public water in accordance with the design standards as approved by the city engineer and in accordance with the city's comprehensive water plan. In areas where public water supply is not available, individual wells shall be provided on each lot, properly placed in relationship to the individual sewage disposal facilities on the same and adjoining lots. Well plans must comply with the state well code, as may be amended, and be submitted for the approval of the city engineer. (Ord. 673, sec. 1, 7-17-2000) 4. Sewage Disposal, Public: Sanitary sewer laterals and service connections shall be installed in accordance with the design standards of the city as approved by the city engineer. The use of sanitary sewer ejector pumps for service to individual lots shall not be allowed, unless approved prior to installation by the city engineer as a private utility fixture. (Ord. 731, sec. 10, 3-17-2003) 5. Sewage Disposal, Private: All individual sewage treatment systems shall be installed in accordance with all applicable state, county, and city requirements 1 . 6. Sanitary Sewer Facilities: Locations, grades, rim and invert elevations, and sizes of all proposed sanitary sewer facilities to serve the tract. 7. Hydrants And Valves: Location of all proposed hydrants and valves for the proposed water mains. (Ord. 673, sec. 1, 7-17-2000) 8. Public Utilities: Public utilities must be extended to plat boundaries unless otherwise approved by the city engineer. (Ord. 731, sec. 11, 3-17-2003; amd. Ord. 1109, 8-18-2025) Notes 1 | 1. MSA 116.07.
Ask a question about Lakeville law
Corpus searches the Lakeville sections it holds and shows the ones that match, with their citations. Free, no sign-in.