§ 244.800 — Ceiling height
Minneapolis Code of Ordinances (Supp. No. 73, Update 1: codified through Ordinance No. 2026-020, adopted June 25, 2026) · Minneapolis Code of Ordinances § 244.800
Corpus is an independent public-information project, not the official City of Minneapolis website. Stable reference: corpuslaw.us/code/0804e976-beff-4033-aa49-e1ec0ac01167
244.800. - Ceiling height.
At least one-half (½) of the floor area of every habitable room shall have a ceiling height of seven (7) feet. However, in dwellings one (1) story and attic in height, attic type bedrooms may be located above the first floor of each dwelling unit if such attic type bedrooms have a minimum ceiling height of not less than seven (7) feet over fifty (50) percent of its floor area and shall be provided with a stairway in full compliance with the building code. The floor area of that part of any room where the ceiling height is less than five (5) feet shall not be considered as part of the floor area in computing the total floor area of the room for the purpose of determining the maximum permissible occupancy thereof. (Code 1960, As Amend., § 73.020; 2009-Or-093, § 2, 9-18-09)
Ask a question about Minneapolis law