Sec. 7-4-36. - Doors.

All building exit doors must be operable from the inside without the use of a key, or special knowledge or effort. Exit doors must not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices must be of an approved type. Notwithstanding anything in sections 7-8-3 through 7-8-7 to the contrary, exit doors from individual dwelling units having an occupant load of ten or less may be provided with a night latch, dead bolt or security chain, provided such devices are operable from the inside without the use of a key or tool, and mounted at a height not to exceed 48 inches above the finished floor.

(Ord. No. 4466, § 4, 4-18-2022)