§ 7-5-14 — Minimum ceiling heights
Code of Ordinances of the City of Rochester, Minnesota (Codified through Ordinance No. 4589, enacted June 1, 2026 (Supp. No. 8, Update 2)) · Rochester Code of Ordinances § 7-5-14
Corpus is an independent public-information project, not the official City of Rochester website. Stable reference: corpuslaw.us/code/ce196fcd-ecc8-4bf2-b765-d35a6e73a969
Sec. 7-5-14. - Minimum ceiling heights.
Habitable spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a minimum clear ceiling height of seven feet (2,134 mm). Exceptions: (1) In one- and two-family dwellings, beams or girders spaced not less than four feet (1,219 mm) on center and projecting a maximum of six inches (152 mm) below the required ceiling height. (2) Basement rooms in one- and two-family dwellings occupied exclusively for laundry, study or recreation purposes, having a minimum ceiling height of six feet four inches (1,932 mm) with a minimum clear height of six feet four inches (1,932 mm) under beams, girders, ducts and similar obstructions. (3) Rooms occupied exclusively for sleeping, study or similar purposes and having a sloped ceiling over all or part of the room, with a minimum clear ceiling height of seven feet (2,134 mm) over not less than one-half of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a minimum clear ceiling height of five feet (1,524 mm) shall be included.
(Ord. No. 4466, § 5, 4-18-2022)
Ask a question about Rochester law
Corpus searches the Rochester sections it holds and shows the ones that match, with their citations. Free, no sign-in.