For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7-7-17 — Electrical equipment

Code of Ordinances of the City of Rochester, Minnesota (Codified through Ordinance No. 4589, enacted June 1, 2026 (Supp. No. 8, Update 2)) · Rochester Code of Ordinances § 7-7-17

Corpus is an independent public-information project, not the official City of Rochester website. Stable reference: corpuslaw.us/code/225b69bc-c077-44d9-ba1a-3025f935eed6

Sec. 7-7-17. - Electrical equipment.

Electrical distribution equipment, motor circuits, power equipment, transformers, wire, cable, flexible cords, receptacles, attachments plugs, flanged surface devices, panel boards, wiring devices, ground fault circuit interrupters, arc-fault circuit interrupters, surge protectors, molded case circuit breakers, low-voltage and medium-voltage fuses and fuse holders, luminaires, lamp holders and retrofit kits, listed low-voltage lighting systems or a lighting system assembled from listed parts, fire pump controllers, ballasts, motors and electronic control, signaling, equipment that provides branch-circuit ground-fault protection, low-voltage power circuit breaker electronic trip units, and communication equipment that have been exposed to water shall be replaced in accordance with the provisions of the International Building Code. Exception: The following equipment shall be allowed to be repaired where an inspection report from the equipment manufacturer or approved manufacturer's representative indicates that the equipment has not sustained damage that requires replacement: (1) Enclosed switches, rated a maximum of 600 volts or less; (2) Busway, rated a maximum of 600 volts; (3) Switchboards, rated a maximum of 600 volts; (4) Manual and magnetic motor controllers; (5) Motor control centers; (6) Alternating current high-voltage circuit breakers; (7) Protective relays, meters and current transformers; (8) Low- and medium-voltage switchgear; (9) Liquid-filled transformers; (10) Cast-resin transformers; (11) Wire or cable that is suitable for wet locations and whose ends have not been exposed to water; (12) Wire or cable, not containing fillers, that is suitable for wet locations and whose ends have not been exposed to water; (13) Motors; (14) Electronic control, signaling and communication equipment.

(Ord. No. 4466, § 7, 4-18-2022)

Ask a question about Rochester law

Corpus searches the Rochester sections it holds and shows the ones that match, with their citations. Free, no sign-in.