Sec. 7-8-6. - Emergency escape openings.

Required emergency escape or rescue openings should be provided in all sleeping rooms in accordance with the most current building code in effect. The escape opening must provide: (1) A minimum 24-inch clear, opening height; (2) A minimum 20-inch clear, opening width; (3) A minimum five-square-foot clear opening; and (4) A finished sill height not more than 44 inches above the floor. Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are permitted to be placed over emergency escape and rescue openings provided that the minimum net clear opening size complies with the most current building code in effect and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening.

(Ord. No. 4466, § 8, 4-18-2022)