For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 26-67 — Amendments to the International Residential Code

Code of Ordinances of the City of Joplin, Missouri (Codified through Ordinance No. 2026-123, enacted September 8, 2026. (Supp. No. 41, Update 3)) · Joplin Municipal Code § 26-67

Corpus is an independent public-information project, not the official City of Joplin website. Stable reference: corpuslaw.us/code/a8b79e9e-2f61-4e34-8e72-3d5263ccf453

Sec. 26-67. - Amendments to the International Residential Code.

The [residential] building code adopted by section 26-66 of this article is hereby amended, changed, and altered, as follows: Section R101.1 is amended by inserting: [City of Joplin, Missouri.]. Section R104.11 is amended by adding the following paragraph to the existing section: The alternative method commonly known as "pole barn" or "laminated pole" type structures shall be limited to commercial buildings and accessory buildings only and not for residential dwelling units. Section R105.2 is amended by deleting item 2 in its entirety. Section R105.2 is amended by deleting item 5 in its entirety. Table R301.2 (1) is amended by inserting: GROUND SNOW LOAD | 30 psf WIND SPEED | 90 mph [TOPOGRAPHIC] EFFECTS | NO [SPECIAL] WIND REGION | NO SEISMIC DESIGN CATEGORY | A WEATHERING | Severe FROST LINE DEPTH | 30 inches TERMITE | Moderate to heavy WINTER DESIGN TEMP | 9 degrees ICE BARRIER UNDERLAYMENT REQUIRED | No FLOOD HAZARDS | December 8, 1976 November 2, 2012 FIRM panels, 29097CINDOC0C, 29097C0142E, 29097C0144E, 29097C0161E, 29097C0163E, 29097C0255E, 29097C0256E, 29097C0257E, 29097C0258E, 29097C0259E, 29097C0266E, , 29097C0267E, 29097C0268E, 29097C0269E, 29097C0276E, 29097C0277E, 29097C0278E, 29097C0279E, 29097C0283E, 29097C0284E, 29097C0285E, 29097C0286E, 29097C0287E, 29097C0288E, 29097C0295E AIR FREEZING INDEX | 500 MEAN ANNUAL TEMP | 55 degrees F Section R403.1.1 is amended by adding wording: "All footings for residential construction are to be at least 16 inches in width and eight inches in thickness." R403.1.6 Foundation anchorage. Replace "…anchor bolts spaced a maximum of 6 feet on center" with "anchor bolts spaced a maximum of four (4) feet on center". Section R 404.1.2.1 Masonry foundation walls is amended to read as follows: "R 404.1.2.1 Masonry foundation walls. Concrete masonry and clay masonry foundation walls shall be constructed as set forth in Table R404.1.1(1), R404.1.1(2), R404.1.1(3) or R404.1.1(4) and shall comply with applicable provisions of Sections R606. In buildings assigned to Seismic Design Categories D0, D1 and D2, concrete masonry and clay masonry foundation walls shall also comply with Section R404.1.4. Rubble stone masonry foundation walls shall be constructed in accordance with Sections R404.1.8 and R606.4.2. Rubble stone masonry walls shall not be used in Seismic Design Categories D0, D1 and D2. Regardless of the height of unbalanced backfill referenced in the tables, every masonry foundation shall have a minimum of one #4 reinforcing bar a maximum of every 4′ on center that is securely anchored in the supporting footing under the wall. The block cells that contain the reinforcing steel and the anchor bolts shall be filled with concrete. If the tables require more than this minimum, then the requirements of the tables shall apply." Section R802.11 Roof tie-down. is amended to read by adding the following paragraph: "All trusses and rafters shall be fastened to the supporting wall assembly by mechanical connections capable of providing the resistance required in Table R802.11. In no case shall the connections be made by solely toe-nailing." Chapter 11 Energy Efficiency is deleted in its entirety and replaced with the Chapter 11 provisions of the 2006 International Residential Code. Exception: The insulation requirement for floors shall not be required. Section P3008.1 Backwater Valves is amended to read as follows: "All plumbing fixtures shall be protected by a backwater valve installed in the building drain." Section E3406.11.1, Exception is amended to read: "Splices shall be permitted within surface-mounted raceways that have removable covers, subject to fill requirements." Section E3608 shall be amended by adding the following paragraph at the beginning: "The primary grounding electrode for all new construction shall be a concrete-encased electrode as defined by section E 3608.1.2"

(Ord. No. 2015-164, § 1, 10-19-15; Ord. No. 2019-047, § 1, 3-18-19)

Ask a question about Joplin law

Corpus searches the Joplin sections it holds and shows the ones that match, with their citations. Free, no sign-in.