§ 8-2 — Definitions
Code of Ordinances of Kansas City, Missouri (Supp. No. 140, Update 1: codified through Ordinance No. 260692, enacted August 13, 2026) · Kansas City Code § 8-2
Corpus is an independent public-information project, not the official City of Kansas City website. Stable reference: corpuslaw.us/code/8b8436cd-4f2a-45e4-b5c7-76f7087e668d
Sec. 8-2. - Definitions.
The following words, terms and phrases, when used in this chapter, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: Abatement project designer means an individual who designs or plans asbestos abatement. Accumulator means the reservoir of a condensing unit receiving the condensate from the condenser. Act means the Clean Air Act as amended, 42 USC 7401 et seq. References to the word "Title" pertain to the titles of the Clean Air Act Amendments of 1990, P.L. 101-549. Actual emissions means the actual rate of emissions of a pollutant from a source operation which is determined as follows: (1) The actual emissions as of a particular date shall equal the average rate, in tons per year, at which the source operation or installation actually emitted the pollutant during the previous two-year period, and which represents normal operation. A different time period for averaging may be used if the director determines it to be more representative. Actual emissions shall be calculated using actual operating hours, production rates and types of materials processed, stored or combusted during the selected time period; (2) The director may presume that source specific allowable emissions for a source operation or installation are equivalent to the actual emissions of the source operation or installation; and (3) For source operations or installations which have not begun normal operations on the particular date, actual emissions shall equal the potential emissions of the source operation or installation on that date. Active supervision means focused attention and intentional observation of the worksite and workers, accurate knowledge of present and potential safety hazards, and availability to assist workers as necessary. Adequately wet means sufficiently mix or penetrate with liquid to prevent the release of particles. If visible emissions are observed coming from asbestos-containing material, then the material has not been adequately wetted. However, the absence of visible emissions is not sufficient evidence of being adequately wet. Administrator means the regional administrator for Region VII, Environmental Protection Agency. Adsorption cycle means the period during which the adsorption system is adsorbing and not desorbing. Adverse impact on visibility means the visibility impairment which interferes with the protection, preservation, management or enjoyment of the visitor's visual experience of a class I area, which is an area designated as class I. This determination must be made on a case-by-case basis taking into account the geographic extent, intensity, duration, frequency and time of visibility impairments, and how these factors correlate with the times of visitor use of the class I area and the frequency and timing of natural conditions that reduce visibility. Aerospace manufacture and/or rework facility means any installation that produces, reworks, or repairs in any amount any commercial, civil, or military aerospace vehicle or component. Aerospace vehicle or component means any fabricated part, processed part, assembly of parts, or completed unit, with the exception of electronic components, of any aircraft. Affected source means a source that includes one or more emission units subject to emission reduction requirements or limitations under title IV of the Act. Affected states means all states contiguous to the permitting state whose air quality may be affected by the permit, permit modification, or permit renewal; or is within 50 miles of a source subject to permitting under title V of the Act. Affected unit means a unit that is subject to emission reduction requirements or limitations under title IV of the Act. Aggressive air sampling means the sweeping of floors, ceilings, walls and other surfaces with the exhaust of a minimum of one horsepower leaf blower or equivalent immediately prior to air monitoring. AHERA means the Asbestos Hazard Emergency Response Act of 1986 (P.L. 99-519). Air cleaning device means any method, process or equipment which removes, reduces or renders less obnoxious air contaminants discharged into the ambient air. Air contaminant means any particulate matter, gas or vapor or any combination of them. Air contaminant source means any and all sources of emission of air contaminants, whether privately or publicly owned or operated. Air-dried coating means a coating which is dried by the use of air or forced warm air at temperatures up to 90 degrees Celsius (194 degrees Fahrenheit). Air pollutant means an agent, or combination of agents, including any physical, chemical, biological, radioactive (including source material, special nuclear material, and byproduct material) substance, or matter which is emitted into or otherwise enters the ambient air. Such term includes any precursors to the formation of any air pollutant, to the extent the administrator of the U.S. Environmental Protection Agency, or the administrator's duly authorized representative has identified such precursor(s) for the particular purpose for which the term air pollutant is used. Air pollution means the presence in the ambient air of one or more air contaminants in quantities, of characteristics and of a duration which directly and approximately cause or contribute to injury to human, plant or animal life or health or to property or which unreasonably interfere with the enjoyment of life or use of property. Air-tight cleaning system means a degreasing machine that is automatically operated and seals at a differential pressure no greater than 0.5 pounds per square inch gauge (psig) during all cleaning and drying cycles. Airless cleaning system means a degreasing machine that is automatically operated and seals at a differential pressure of 25 torr (25.0 millimeters of Mercury (mmHg)) (0.475 pounds per square inch (psi)) or less, prior to the introduction of solvent vapor into the cleaning chamber and maintains differential pressure under vacuum during all cleaning and drying cycles. Alcohol means isopropanol, isopropyl alcohol, normal propyl alcohol, or ethanol. Alcohol substitutes means nonalcohol additives that contain volatile organic compounds and are used in fountain solution. Allowable emissions means the emission rate calculated using the maximum rated capacity of the installation (unless the source is subject to enforceable permit conditions which limit the operating rate or hours of operation, or both) and the most stringent of the following: (1) Emission limit established in any applicable emissions control rule, including those with a future compliance date. (2) The emission rate specified as a permit condition. Allowance means an authorization, allocated to an affected unit by the administrator under title IV of the Act to emit during or after a specified calendar year, one ton of sulfur dioxide (SO 2 ). Alternate site analysis means an analysis of alternative sites, sizes, production processes, and environmental control techniques for the proposed source which demonstrates that benefits of the proposed installation significantly outweigh the environmental and social costs imposed as a result of its location, construction or modification. Alternative method means any method sampling and analyzing for on air pollutant that is not a reference or equivalent method, but that has been demonstrated to the director's satisfaction to, in specific cases, produce results adequate for a determination of compliance. Ambient air means that portion of the atmosphere, external to buildings, to which the general public has access. Ambient air increments means the limited increases of pollutant concentrations in ambient air over the baseline concentration. Ambient air quality standards means the National Primary and Secondary Ambient Air Quality Standards to be found in 40 CFR part 50. Anode bake plant means a facility which produces carbon anodes for use in a primary aluminum reduction installation. Applicable implementation plan or applicable state implementation plan (SIP) means the portion (or portions) of the SIP or most recent revision thereof, which has been approved under section 110(k) of the Act, a federal implementation plan promulgated under section 110(c) of the Act, or a plan Promulgated or approved pursuant to section 301(d) of the Act (tribal implementation plan) and which implements the relevant requirements of the Act. Applicable requirement means all of the following listed in the Act: (1) Any standard or requirement provided for in the implementation plan approved or promulgated by the U.S. Environmental Protection Agency (EPA) through rulemaking under title I of the Act that implements the relevant requirements, including any revisions to that plan promulgated in 40 CFR part 52. (2) Any term or condition of any preconstruction permit issued pursuant to regulations approved or promulgated through rulemaking under title I including, parts C or D of the Act. (3) Any standard or requirement under section 111 of the Act, including section 111(d). (4) Any standard or requirement under section 112 of the Act, including any requirement concerning accident prevention under section 112(r)(7). (5) Any standard or requirement of the acid rain program under title IV of the Act or the regulations promulgated thereunder. (6) Any requirements established pursuant to section 504(b) or section 114(a)(3) of the Act. (7) Any standard or requirement governing solid waste incineration, under section 129 of the Act. (8) Any standard or requirement for consumer and commercial products, under section 183(e) of the Act. (9) Any standard or requirement for tank vessels under section 183(f) of the Act. (10) Any standard or requirement of the program to control air pollution from outer continental shelf sources, under section 328 of the Act. (11) Any standard or requirement of the regulations promulgated to protect stratospheric ozone under title VI of the Act unless the administrator has determined that such requirements need not be contained in a title V permit; (12) Any national ambient air quality standard or increment or visibility requirement under part C of the title I of the Act, but only as it would apply to temporary sources permitted pursuant to section 504(e). (13) Any standard or requirement established in RSMo 643.010—643.190 of the Missouri Air Conservation Law and rules adopted under them. Applicant means a person, firm, corporation, government, or other entity that has applied for a permit. Application means an approved document submitted to the regulatory authority as an official request for a permit. Appropriate warning sign means any asbestos hazard warning sign that complies with the regulations of the United States Occupation Safety and Health Administration (OSHA) or the United States Environmental Protection Agency (EPA) rules. Approved means acceptable to the regulatory authority based on a determination of conformity with principles, practices, and generally recognized standards that protect public health. Approved source means a source of fuel which has been found by the department director, after the tests as he/she may require, to be in compliance with these sections of the Code. Approved waste disposal site means a solid waste disposal area that is authorized by the department director to receive friable asbestos containing solid wastes. Aqueous solvent means a solvent in which water is the primary ingredient (greater than 80 percent by weight or greater than 60 percent by volume of solvent solution as applied must be water). Detergents, surfactants, and bioenzyme mixtures and nutrients may be combined with the water along with a variety of additives such as organic solvents (e.g., high boiling point alcohols), builders, saponifiers, inhibitors, emulsifiers, pH buffers, and antifoaming agents. Aqueous solutions must have a flash point greater than 93 degrees Celsius (200 degrees Fahrenheit) and the solution must be miscible with water. Asbestos means the asbestiform varieties of chrysolite, crocidolite, amosite, anthophyllite, tremolite and actinolite. Asbestos abatement means the encapsulation, enclosure, or removal of asbestos-containing materials, in or from a building, or air contaminant source, or preparation of friable asbestos-containing material prior to demolition. Asbestos abatement contractor means any person who by agreement, contractual or otherwise, conducts asbestos abatement projects at a location other than their own place of business. Asbestos abatement project means an activity undertaken to encapsulate, enclose or remove ten square feet, or 16 linear feet or more of friable asbestos-containing materials from buildings and other air contaminant sources, or to demolish buildings and other air contaminant sources containing ten square feet or 16 linear feet or more. Asbestos abatement supervisor means an individual who directs, controls or supervises others in asbestos abatement projects. Asbestos abatement worker means an individual who engages in asbestos abatement projects. Asbestos air sampling professional means an individual who by qualifications and experience is proficient in asbestos abatement air monitoring. The individual shall conduct, oversee or be responsible for air monitoring of asbestos abatement projects before, during and after the project has been completed. Asbestos air sampling technician means an individual who has been trained by an air sampling professional to do air monitoring. Such individual conducts air monitoring of an asbestos abatement project before, during and after the project has been completed. Asbestos caution label means a label that complies with applicable Environmental Protection Agency (EPA), Department Of Transportation (DOT) and OSHA rule requirements and is securely affixed to a waste container that contains friable asbestos materials. Asbestos-containing material (ACM) means any material or product which contains more than one percent asbestos by weight. Asbestos debris means material that results from removal or deterioration of asbestos-containing material. Asbestos dismantling project means an asbestos abatement project that includes the dissembling, handling and moving of the components of any structural or equipment item that has been coated with friable asbestos-containing material without first removing this material. Asbestos encapsulation project means an asbestos project involving the coating of a friable asbestos-containing surface material with a sealing substance with the intended purpose of preventing the continued release of asbestos fibers from the material into the air. This definition shall not include: (1) The repainting of a previously painted asbestos-containing surface primarily for the purpose of improving appearance. (2) The application of a sealing material to a surface subsequent to the removal of asbestos from it. (3) The application of an encapsulant to asbestos-containing material while the material is being removed. (4) The application of a sealing substance to less than ten square feet or less than 16 linear feet of friable asbestos-containing material that is contiguous to other types of material. (5) The application of a sealing substance to asbestos-containing material that has previously been enclosed or encapsulated. (6) The painting of nonfriable asbestos-containing material. Asbestos enclosure project means an asbestos abatement project that involves the construction of an air tight impact resistant barrier to isolate a surface coated with asbestos-containing material. Asbestos maintenance operation means any operation that involves the removal or cleanup of less than ten square feet or less than 16 linear feet of friable asbestos-containing material from any type of structure or equipment item in order to repair, replace or maintain the item and anything attached to it. Asbestos projects: Asbestos removal project means an asbestos abatement project consisting of activities that involve, and are required, to take out friable asbestos-containing material from any facility. This definition includes, but is not limited to, activities associated with the cleanup of loose friable asbestos-containing debris or refuse, or both, from floors and other surfaces. ASME means the American Society of Mechanical Engineers. Asphalt prime coat means an application of low-viscosity liquid asphalt to an absorbent surface such as a previously untreated surface. Asphalt seal coat means an application of a thin asphalt surface treatment used to waterproof and improve the texture of an absorbent surface or a nonabsorbent surface such as asphalt or concrete. ASTM means the American Society of Testing and Materials. Automobile means a four-wheel passenger motor vehicle or derivative capable of seating no more than 12 passengers. Automobile and light duty truck surface coating operations means the application, flashoff and curing of primer, primer-surfacer, topcoat and final repair coatings during the assembly of passenger cars and light duty trucks, excluding such operations when performed by customizers, body shops and other repainters, and excluding the following operations: (1) Wheel coatings. (2) Miscellaneous antirust coatings. (3) Truck interior coatings. (4) Interior coatings. (5) Flexible coatings. (6) Sealers and adhesives. (7) Plastic parts coatings. Automotive underbody deadeners means any coating applied to the underbody of a motor vehicle to reduce the noise reaching the passenger compartment. Base year means the year chosen in the state implementation plan to directly correlate emissions of the nonattainment pollutant in the nonattainment area with ambient air quality data pertaining to the pollutant. From the base year, projections are made to determine when the area will attain and maintain the ambient air quality standards. Basecoat means a coat of a colored material, usually opaque, that is applied before graining inks, glazing coats, or other opaque finishing materials and is usually top coated for protection. Baseline area means the continuous area in which the source constructs as well as those portions of the intrastate area which are not part of a nonattainment area and which would receive an air quality impact equal to or greater than one microgram per cubic meter (1 ug/m 3 ) annual average (established by modeling) for each pollutant for which an installation receives a permit under section 8-10(H) (Attainment and Unclassified Area Permit) and for which increments have been established in section 8-10(K) table 1 (Ambient Air Increment Table). Each of these areas are references to the standard United States Geological Survey (USGS) County-Township-Range-Section system. The smallest unit of area for which a baseline date will be set is one section (one square mile). Baseline concentration means that ambient concentration level which exists at locations of anticipated maximum air quality impact or increment consumption within a baseline area at the time of the applicable baseline date, minus any contribution from installations, modifications and major modifications subject to section 8-10(H) (Attainment and unclassified area permit) or subject to 40 CFR 52.21 (Prevention of significant deterioration of air quality) on which construction commenced on or after January 6, 1975 for sulfur dioxide and particulate matter and February 8, 1988 for nitrogen dioxide. The baseline concentration shall include contributions from: (1) The actual emissions of other installations in existence on the applicable baseline date. (2) The potential emissions of installations and major modifications which commenced construction before January 6, 1975, but were not in operation by the applicable baseline date. Baseline date means the date, for each baseline area, of the first complete application after August 7, 1977, for sulfur dioxide and particulate matter, and February 8, 1988 for nitrogen dioxide for a permit to construct and operate an installation subject to section 8-10(H) (Attainment and unclassified area permit) or subject to 40 CFR 52.21 (Prevention of significant deterioration of air quality). Batch means a discontinuous process involving the bulk movement of material through sequential manufacturing steps, typically not characterized as steady state. Best available control technology (BACT) means an emission limitation, including a visible emissions limit, based on the maximum degree of reduction for each pollutant which would be emitted from any proposed installation or major modification which the director on a case-by-case basis, taking into account energy, environmental and economic impacts and other costs, determines is achievable for such installation or major modification through application of production processes or available methods, systems and techniques, including fuel cleaning or treatment or innovative fuel combustion techniques for control of such pollutant. In no event shall application of best available control technology (BACT) result in emission of any pollutant which would exceed the emissions allowed by any applicable emission control regulation, including new source performance standards (NSPS) established in 10 CSR 10-6.070 and 40 CFR 60 and National Emissions Standards for Hazardous Air Pollutants established in 10 CSR 10-60.080 and 40 CFR 61. If the director determines that technological or economic limitations on the application of measurement methodology to a particular source operation would make the imposition of an emission limitation infeasible, a design, equipment, work practice, operational standard, or combination of these may be prescribed instead to require the application of Best Available Control Technology (BACT). This standard, to the degree possible, shall set forth the emission reduction achievable by implementation of such design, equipment, work practice or operation, and shall provide for compliance by means which achieve equivalent results. Board means the air quality control board. Boiler means an enclosed fossil or other fuel-fired combustion device used to produce heat and to transfer heat to recirculating water, steam, or other medium. Building means any structure excluding single-family, owner-occupied dwellings, and vacant public or privately-owned residential structures of four dwelling units or less being demolished for the sole purpose of public health, safety or welfare. Excluded structures must be geographically dispersed, demolished pursuant to a public safety determination, and must pose a threat to public safety. BTU means British thermal unit(s). Can coating means a surface coating applied to a cylindrical steel or aluminum container. The container can be two pieces (made by a drawn and wall-ironed shallow cup with only one end) or three pieces (made by a rectangular material rolled into a cylinder and the attachment of two end pieces). Capacity factor means ratio (expressed as a percentage) of a power generating unit's actual annual electric output (expressed in Mwe-hr) divided by the unit's nameplate capacity multiplied by 8,760 hours. Capture device means a hood, enclosed room, floor sweep, or other means of collecting solvent emissions or other pollutants into a duct so that the pollutant can be directed to a pollution control device such as an incinerator or carbon adsorber. Capture efficiency means the fraction of all organic vapors or other pollutants generated by a process that is directed to a control device. Carbon adsorption system means a device containing adsorbent material (for example, activated carbon, aluminum, silica gel); an inlet and outlet for exhaust gases; and a system to regenerate the saturated adsorbent. The carbon adsorption system must provide for the proper disposal or reuse of all volatile organic compounds adsorbed. Carbon bed breakthrough means a concentration of VOC in the carbon adsorption device exhaust that exceeds ten percent by weight of the inlet VOC concentration. Carryout means materials such as gravel, sand, and dirt from vehicles or trailers which falls onto a paved public road or shoulder. Catalytic incinerator means a control device using a catalyst to allow combustion to occur at a lower temperature. Category I nonfriable ACM means asbestos-containing packings, gaskets, resilient floor covering and asphalt roofing products containing more than one percent asbestos as determined using the method specified in 40 CFR part 763, appendix A, section 1, Polarized Light Microscopy. Category II nonfriable ACS means any material, excluding category I nonfriable ACM, containing more than one percent asbestos as determined using the methods specified in 40 CFR part 763, subpart F, appendix A, section 1, Polarized Light Microscopy that, when dry, cannot be crumbled, pulverized or reduced to powder by hand pressure. (CFR) Code of Federal Regulations means any incorporation by reference of a CFR regulation contained in this chapter shall incorporate that regulation, as amended, as of the date of passage of the ordinance containing the reference. Circumvention means building, erecting, installing or using any article, machine, equipment, process or method which, when used, would conceal an emission that would otherwise constitute a violation of an applicable standard or requirement. That concealment includes, but is not limited to, the use of gaseous adjutants to achieve compliance with a visible emissions standard, and the piecemeal carrying out of an operation to avoid coverage by a standard that applies only to operations larger than a specific size. City means the City of Kansas City, Missouri. Class A source means either a class A1, A2 or A3 source as defined in this section. Class A1 source means any air contaminant source with the potential to emit equal to or greater than 100 tons per year of an air contaminant. Class A2 source means any air contaminant source, which is not a class A1 source, and with the potential, air cleaning devices not considered, to emit equal to or greater than 100 tons per year of an air contaminant. Class A3 source means any air contaminant source which emits or has the potential to emit, ten tons per year or more of any hazardous air pollutant or 25 tons of any combination of hazardous air pollutants, or as defined pursuant to section 112 of the Act. Class B source means any air contaminant source with the potential, air cleaning devices not considered, to emit equal to or greater than the de minimis amounts of an air contaminant established by the commission, but not a class A source. Clean room means an uncontaminated area or room which is part of the worker decontamination enclosure system. Clean wood means wood that has not been treated (including, but not limited to, treatment with copper chromium arsenate, creosote, or pentachlorophenol) and has no paint, stain, or any other type of coating. Clear coat means a coating which lacks color and opacity or is transparent and uses the undercoat as a reflectant base or undertone color. This term also includes corrosion preventive coatings used for the interior of drums or pails. Closed container means a container with a cover fastened in place so that it will not allow leakage or spilling of the contents. Coating means a protective, decorative, or functional material applied in a thin layer to a surface. Such materials include, but are not limited to, paints, topcoats, varnishes, sealers, stains, washcoats, basecoats, inks, and temporary protective coatings. Inks not included in the "coating" definition are for the purpose of 10 CSR 10-2.230 (Control of Emissions from Industrial Surface Coating Operations), ink used in printing operations regulated under 10 CSR 10-2.290 (Control of Emissions from Rotogravure and Flexographic Printing Facilities), and 10 CSR 10-2.340 (Control of Emissions from Lithographic Printing Installations). Coating applicator means an apparatus used to apply a surface coating. Coating line means one or more apparatus or operation(s) which include a coating applicator, flash-off area, and oven where a surface coating is applied, dried or cured or a combination of these. Coating solids (or solids) means the part of the coating that remains after the coating is dried or cured; solids content is determined using data from EPA Method 24 or an alternative or equivalent method. Coil coating means the coating of any flat metal sheet or strip that comes in rolls or coils. Cold cleaning means the batch process of cleaning removing soils from metal surfaces by spraying, brushing, flushing, or immersion while maintaining the solvent below its boiling point. Cold cleaner means any device or piece of equipment that contains and/or uses liquid solvent, into which parts are placed to remove soils from the surfaces of the parts or to dry the parts. Cleaning machines that contain and use heated nonboiling solvent to clean the parts are classified as cold cleaning machines. Combustion chamber means the discrete equipment, chamber or space of an incinerator in which the products of pyrolysis are combusted in the presence of excess air so that carbon is burned to carbon dioxide. Combustion chamber does not include breaching or stacks of the incinerator. Commence means for the purposes of major stationary source construction or major modification, the owner or operator has all necessary preconstruction approvals or permits and (1) Began, or caused to begin, a continuous program of actual on-site construction of the source, to be completed within a reasonable time. (2) Entered into binding agreements or contractual obligations, which cannot be canceled or modified without substantial loss to the owner or operator, to undertake a program of actual construction of the source to be completed within a reasonable time. Commenced operation means the initial setting into operation of any air pollution control equipment or process equipment. Commercial vehicle means any motor vehicle, other than a passenger vehicle, and any trailer, semitrailer, or pole trailer drawn by such motor vehicle, that is designed, used, and maintained for the transportation of persons or property for hire, compensation, profit, or in the furtherance of a commercial enterprise. Commission means the Missouri Air Conservation Commission established pursuant to RSMo 643.040. Condensate (hydrocarbons) means a hydrocarbon liquid separated from natural gas which condenses due to changes in the temperature and/or pressure and remains liquid at standard conditions. Condenser means any heat transfer device used to liquefy vapors by removing their latent heats of vaporization, including but not limited to shell and tube, coil, surface or contact condensers. Conservation vent means any valve designed and used to reduce evaporation losses of volatile organic compounds (VOC) by limiting the amount of air admitted to, or vapors released from, the vapor space of a closed storage vessel. Construction means fabricating, erecting, reconstructing or installing a source operation. Construction shall include installation of building supports and foundations, laying of underground pipe work, building of permanent storage structures, and other construction activities related to the source operation. Containment means the area where an asbestos abatement project is conducted. The area must be enclosed either by a glove bag or plastic sheeting barriers. Continuous emissions monitoring system (CEMS). Defined as follows: (1) For the purpose of 10 CSR 10-6.350 (Emission Limitations and Emissions Trading of Oxides of Nitrogen) and 10 CSR 10-6.360 (Control of NOx Emissions From Electric Generating Units and Non-Electric Generating Boilers), the equipment required to sample, analyze, measure, and provide, by readings taken at least once every 15 minutes of the measured parameters, a permanent record of nitrogen oxides emissions, expressed in tons per hour for nitrogen oxides. The following systems are component parts included, consistent with 40 CFR 75 (Continuous Emission Monitoring), in a continuous emissions monitoring system: a. Flow monitor; b. Nitrogen oxides pollutant concentration monitors; c. Diluent gas monitor (oxygen or carbon dioxide) when such monitoring is required; d. A continuous moisture monitor when such monitoring is required; and e. An automated data acquisition and handling system; and (2) For all other purposes, a monitoring system for continuously measuring and recording the emissions of a pollutant from an affected facility. Continuous opacity monitoring system (COMS) means all equipment required to continuously measure and record the opacity of emissions within a stack or duct. Continuous opacity monitoring systems (COMS) consists of sample interface, analyzer and data recorder components and usually includes, at a minimum, transmissometers, transmissometer control equipment, and data transmission, acquisition, and recording equipment. Control curtain means any of the three following types of closure devices that are to be constructed of not less than four mil thick plastic sheeting material and installed in an entry way of an area that is considered to be contaminated with free asbestos fibers. (1) A ventilation curtain that allows unrestricted air flow into a contaminated area when it is being ventilated with an exhaust fan. This curtain consists of a single flap that opens into the contaminated area and is securely fastened across the top of the entryway framework so that it overlaps both sides of the entryway by not less than 12 inches and the base of the entryway by not less than three inches. (2) A confinement curtain that restricts the movement of air into, and from, an unventilated and contaminated area. This curtain consists of three constructed baffles that cover the entire area of the entryway and are securely fastened along the top of the entryway framework and along alternate sides of locations in a manner that will allow two of the curtains to fully cover the entryway opening while a person passes through the third curtain. An airlock arrangement consisting of two confinement curtain entryways that are located at last three feet apart may be substituted for the triple baffle arrangement; or (3) A closure device for which written department approval is required. Control device means any equipment that reduces the quantity of a pollutant that is emitted to the air. The device may destroy or secure the pollutant for subsequent recovery. Includes, but is not limited to, incinerators, carbon adsorbers, and condensers. Control device efficiency means the ratio of the pollution released by a control device and the pollution introduced to the control device, expressed as a fraction. Control system means the combination of capture and control devices used to reduce emissions to the atmosphere. Conveyorized degreaser means a type of degreaser in which the parts are loaded continuously. Conveyorized degreasing means the continuous process of cleaning and removing soils from metal surfaces by operating with either cold or vaporized solvent. Criteria pollutant or standard means any pollutants for which there is established a National Ambient Air Quality Standard at 40 CFR 50 (National Primary and Secondary Ambient Air Quality Standards). Critical item/violation means a provision of this Code, that, if in noncompliance, is more likely that other violations to contribute to air contamination, personal injury, illness, or environmental hazard. Crude oil means a naturally occurring mixture which consists of hydrocarbons and sulfur, nitrogen or oxygen derivatives of hydrocarbons (or a combination of these derivatives) which is a liquid at standard conditions. Custody transfer means the transfer of produced crude oil or condensate, or both, after processing or treating, or both, in the producing operations, from storage tanks or automatic transfer facilities to pipelines or any other forms of transportation. Cutback asphalt means any asphaltic cement that has been liquefied by blending with volatile organic compound (VOC) liquid diluents. Decontamination facility means the serial arrangement of rooms or spaces for the purpose of separating the work site from the building environment upon entering the work site and for the cleaning of persons, equipment and contained waste prior to returning to the clean environment. Degreasing means a solvent metal cleaning in which nonaqueous solvents are used to clean and remove soils from metal surfaces. Delivery vessel means a tank truck, trailer, railroad tank car or drums. De minimis levels means any emissions level less than or equal to the rates listed as follows: Air Contaminant | Emission Rate (Tons per year) Carbon monoxide | 100.0 Nitrogen oxides | 40.0 Particulate matter PM | 25.0 PM10 | 15.0 PM2.5 | 10.0 SO 2 (PM2.5 precursor) | 40.0 NO x (PM2.5 precursor) (emissions of nitrogen oxides are considered precursors to PM2.5 unless the state or EPA successfully demonstrates that emissions in a specific area are not a significant contributor to that area's ambient PM2.5 concentrations) | 40.0 Sulfur dioxide | 40.0 Ozone VOC (ozone precursor) | 40.0 NOx (ozone precursor) | 40.0 Lead | 0.6 Fluorides (excluding hydrogen fluoride) | 3.0 Sulfuric acid mist | 7.0 Hydrogen sulfide | 10.0 Total reduced sulfur (including hydrogen sulfide) | 10.0 Reduced sulfur compounds (including hydrogen sulfide) | 10.0 Municipal waste combustor organics (measured as total tetra-through octa-chlorinated dibenzo-p-dioxins and dibenzofurans) | 3.5 × 10 -6 Municipal waste combustor metals (measured as particulate matter) | 15.0 Municipal waste combustor acid gases (measured as sulfur dioxide and hydrogen chloride) | 40.0 Municipal solid waste landfill emissions (measured as nonmethane organic compounds) | 50.0 Hazardous air pollutant (each) | 10.0 Sum of hazardous air pollutants | 25.0 Demolition project means the wrecking, razing, intentional burning, or removal of any load-supporting structural member or portion of a structure together with any related handling operation. Department means the Missouri Department of Natural Resources, which includes the director thereof, or the person or division or program within the department delegated the authority to render the decision, order, determination, finding, or other action that is subject to review by the commission. Department-approved in-house project means an asbestos abatement project in a person's own facility using their own trained facility employees; the project has received departmental approval as part of planned renovation operations. Designated representative means a responsible individual authorized by the owner or operator of an affected source and of all affected units at the source, as evidenced by a certificate of representation submitted in accordance with 40 CFR 72, subpart B to represent and legally bind each owner and operator, as a matter of federal law, in matters pertaining to the acid rain program. Whenever the term responsible official is used in 40 CFR 70, 10 CSR 10-6.065 or in any other regulations implementing Title V of the Act, it shall be deemed to refer to the designated representative with regard to all matters under the acid rain program. Diesel engine means a compression ignited two or four stroke engine in which liquid fuel is injected into the combustion chamber and ignited when the air charge has been compressed to a temperature sufficiently high for auto-ignition. Director means the director of the city department assigned responsibility for the air quality control program, or his duly authorized representative. Dispersion technique. (1) Any technique designed to affect the concentration of a pollutant in the ambient air by: a. Using that portion of a stack which exceeds good engineering practice stack height; b. Varying the rate of emission of a pollutant according to atmospheric conditions or ambient concentrations of that pollutant; or c. Increasing final exhaust gas plume rise by manipulating source process parameters, exhaust gas parameters, stack parameters or combining exhaust gases from several existing stacks into one stack; or other selective handling of exhaust gas streams so as to increase the exhaust gas plume rise; and (2) This definition does not include: a. The reheating of a gas stream, following use of a pollution control system, for the purpose of returning the gas to the temperature at which it was originally discharged from the installation generating the gas stream; b. The merging of exhaust gas streams where: 1. The installation owner or operator demonstrates that the installation was originally designed and constructed with the merged gas streams; 2. After July 8, 1985 the merging is part of a change in operation at the installation that includes the installation of emissions control equipment and is accompanied by a net reduction in the allowable emissions of a pollutant This exclusion from the definition of "dispersion technique" shall apply only to the emission limitation for the pollutant affected by a change in operation; or 3. Before July 8, 1985 the merging was part of a change in operation at the installation that included the installation of emissions control equipment or was carried out for sound economic or engineering reasons. Where there was an increase in the emission limitation or in the event that no emission limitation was in existence prior to the merging, the director shall presume that merging was significantly motivated by an intent to gain emissions credit for greater dispersion. Without a demonstration by the source owner or operator that merging was not significantly motivated by that intent, the director shall deny credit for the effects of merging in calculating the allowable emissions for the source; c. Smoke management in agricultural or silvicultural prescribed burning programs; d. Episodic restrictions on residential woodburning and open burning; or e. Techniques under part (1)c. of this definition which increase final exhaust gas plume rise where the resulting allowable emissions of sulfur dioxide from the installation do not exceed 5,000 tons per year. Distillation operation means an operation separating one or more feed stream(s) into two or more exit streams, each exit stream having component concentration different from those in the feed stream(s). The separation is achieved by the redistribution of the components between the liquid- and vaporphase as they approach equilibrium within the distillation unit. Distillation unit means a device or vessel in which distillation operations occur, including all associated internals (such as trays or packing) and accessories (such as reboiler, condenser, vacuum pump, stream jet, etc.), plus any associated recovery system. Draft permit means the version of a permit for which the permitting authority offers public participation or affected state review. Drum means any cylindrical container of 13 to 110 gallon capacity. Dry cleaning installation means an installation engaged in the cleaning of fabrics in an essentially nonaqueous solvent by means of one or more washes in solvent, extraction of excess solvent by spinning, and drying by tumbling or in an airstream. The installation includes but is not limited to any washer, dryer, filter and purification systems, waste disposal systems, holding tanks, pumps, and attendant piping and valves. DSCF means dry standard cubic foot of exhaust gas. DSCM means dry standard cubic meter of exhaust gas. Electric generating unit (EGU) means any fossil-fuel-fired boiler or turbine that serves an electrical generator with the potential to use more than 50 percent of the usable energy from the boiler or turbine to generate electricity. Emergency asbestos abatement project means an asbestos abatement project that must be undertaken immediately to prevent imminent severe human exposure or to restore essential operation. Emergency standby generator means a generator operated only during times of loss of primary power at the facility that is beyond the control of the owner or operator of the facility or during routine maintenance. Emission means the release or discharge, whether directly or indirectly, into the atmosphere of one or more air contaminants. Emission inventory means a listing of information on the location, type of source, type and quantity of pollutant emitted, as well as other parameters of the emissions. Emission limitation means a regulatory requirement, permit condition, or consent agreement which limits the quantity, rate, or concentration of emissions on a continuous basis, including any requirement which limits the level of opacity, prescribes equipment, sets fuel specifications, or prescribes operation or maintenance procedures for an installation to assure continuous emission reduction. Emissions unit means any part or activity of an installation that emits or has the potential to emit any regulated air pollutant or any pollutant listed under section 112(b) of the Act. This term is not meant to alter or affect the definition of the term "unit" for the purposes of title IV of the Act. Emulsified asphalt means an emulsion of asphalt cement and water that contains a small amount of an emulsifying agent, as specified in ASTM D 977-12b or ASTM D 2397-12. Enamel means a surface coating that is a mixture of paint and varnish, having vehicles similar to those used for varnish, but also containing pigments. End exterior coating means a coating applied to the exterior end of a can to provide protection to the metal. End seal compound means the gasket forming coating used to attach the end pieces of a can during manufacturing or after filling with contents. Equipment means any item that is designed or intended to perform any operation and includes any item attached to it to assist in the operation. Equivalent method means any method of sampling and analyzing for an air pollutant that has been demonstrated to the director's satisfaction to have a consistent and quantitatively known relationship to the reference method under specific conditions. Excess emissions means the emissions which exceed the requirements of any applicable emission control regulation. Excessive concentration. (1) For installations seeking credit for reduced ambient pollutant concentrations from stack height exceeding that defined in part (2) of the definition of "good engineering practice stack height," an excessive concentration is a maximum ground-level concentration due to emissions from a stack due in whole or part to downwash, wakes or eddy effects produced by nearby structures or nearby terrain features which are at least 40 percent in excess of the maximum concentration experienced in the absence of the downwash, wakes or eddy effects, and that contributes to a total concentration due to emissions from all installations that is greater than an ambient air quality standard. For installations subject to the prevention of significant deterioration program as set forth in section 8-10(H), an excessive concentration alternatively means a maximum ground-level concentration due to emissions from a stack due to the same conditions as mentioned previously and is greater than a prevention of significant deterioration increment. The allowable emission rate to be used in making demonstrations under this definition shall be prescribed by the new source performance regulation as referenced by 10 CSR 10-6.070 (New Source Performance Regulations) for the source category unless the owner or operator demonstrates that this emission rate is infeasible. Where demonstrations are approved by the director, an alternative emission rate shall be established in consultation with the source owner or operator. (2) For installations seeking credit after October 11, 1983 for increases in stack heights up to the heights established under part (1) of the definition of "good engineering practice stack height," an excessive concentration is either: a. A maximum ground-level concentration due in whole or part to downwash, wakes or eddy effects as provided under part (1) of the definition for "excessive concentration," except that the emission rate used shall be the applicable emission limitation (or, in the absence of this a limit, the actual emission rate); or b. The actual presence of a local nuisance caused by the stack, as determined by the director; and (3) For installations seeking credit after January 12, 1979 for a stack height determined under part (2) of the definition of "good engineering practice stack height," where the director requires the use of a field study or fluid model to verify good engineering practice stack height, for installations seeking stack height credit after November 9, 1984 based on the aerodynamic influence of cooling towers and for installations seeking stack height credit after December 31, 1970 based on the aerodynamic influence of structures not adequately represented by the equations under part (2) of the definition for "good engineering practice stack height," a maximum ground-level concentration due in whole or part to downwash, wakes or eddy effects that is at least 40 percent in excess of the maximum concentration experienced in the absence of downwash, wakes or eddy effects. Existing. (1) For the purpose of restriction of particulate matter emissions from fuel burning equipment used for indirect heating, any source that is existing, installed, or under construction on February 15, 1979, in the Kansas City metropolitan area, except that if any source in this area subsequently is altered, repaired, or rebuilt at a cost of 30 percent or more of its replacement cost, exclusive of routine maintenance, it shall no longer be existing but shall be considered as new; and (2) For all other purposes, any equipment, machine, device, article, contrivance or installation shall mean in being, installed or under construction in the Kansas City metropolitan area on September 25, 1968, except that if any equipment, machine, device, article, contrivance or installation subsequently is altered, repaired or rebuilt at a cost of 50 percent or more of its replacement cost exclusive of routine maintenance, it shall no longer be existing, but shall be considered new as defined in this Code. The cost of installing equipment designed principally for the purpose of air pollution control is not to be considered a cost of altering, repairing or rebuilding existing equipment for the purpose of this definition. Exterior coating (two-piece) means a surface coating used to coat the outside surface of a two-piece can. Used to provide protection from the lithograph or printing operations. External floating roof means a storage vessel cover in an open top tank consisting of a double deck or pontoon single deck which rests upon and is supported by the liquid being contained and is equipped with a closure seal(s) to close the space between the roof edge and tank wall. Extreme environmental conditions means the exposure to any of the weather all of the time, temperatures consistently above 95 degrees Celsius, detergents, abrasive and scouring agents, solvents, corrosive atmospheres, or similar environmental conditions. Extreme performance coating means a coating used on a metal or plastic surface where the coated surface is, in its intended use, subject to the following: (1) Chronic exposure to corrosive, caustic, or acidic agents, chemicals, chemical fumes, chemical mixtures, or solutions; (2) Repeated exposure to temperatures in excess of 250 degrees Fahrenheit; or (3) Repeated heavy abrasion, including mechanical wear and repeated scrubbing with industrial grade solvents, cleansers, or scouring agents. Fabric coating means a coating applied to a textile substrate by dipping or by means of knife or roll. Fabric filter or baghouse means an add-on air pollution control system that removes particulate matter and nonvaporous metals emissions by passing flue gas through filter bags. Facility. Defined as follows: (1) For the purposes of asbestos projects, any institutional, commercial, public, industrial, or residential structure, installation, or building (including any structure, installation, or building containing condominiums or individual dwelling units operated as a residential cooperative, but excluding residential buildings having four or fewer dwelling units); any ship; and any active or inactive waste disposal site. Any building, structure, or installation that contains a loft used as a dwelling is not considered a residential structure, installation, or building. This definition does include any structure, installation, or building that was previously subject to 40 CFR 61, subpart M (National Emission Standard for Asbestos), regardless of its current use or function; and (2) For all other purposes, see the definition of "installation." Federal agency means a federal department, agency, or instrumentality of the federal government. Federally enforceable means all limitations and conditions which are enforceable by the administrator, including those requirements developed pursuant to 40 CFR 60 and 61, requirements within any applicable state implementation plan, any permit requirements established pursuant to 40 CFR part 52.21, or under regulations pursuant to 40 CFR part 51, subpart I, including operating permits issued under an EPA-approved program that is incorporated into the state implementation plan and expressly requires adherence to any permit issued under the program. Final permit means the version of a part 70 permit issued by the permitting authority that has completed all review procedures as required by part 70.7 (Permit issuance, renewal, reopenings, and revisions) and 70.8 (Permit review by EPA and affected states). Final repair means the final coatings applied to correct topcoat imperfections after the complete assembly of the automobile. Finishing operation means those activities in which a finishing material is applied to a substrate and is subsequently air-dried, cured in an oven, or cured by radiation. Firebox means the chamber or compartment of a boiler or furnace in which materials are burned but does not mean the combustion chamber of an incinerator. Flare means an open combustor without enclosure or shroud. Flash-off area means the space between the application area and the oven. Flexible coating means a coating that is required to comply with engineering specifications for impact resistance, mandrel bend, or elongation as defined by the original equipment manufacturer. Flexographic printing means the application of words, designs, and pictures to a substrate by means of a roll printing technique in which the pattern to be applied is raised above the printing roll and the image carrier is made of rubber or other elastomeric materials. Flush cleaning means the removal of contaminants such as dirt, grease and coatings from a vehicle, component, or coating equipment by passing solvent over, into, or through the item being cleaned. The solvent may be simply be poured into the item cleaned and then drained, or be assisted by air or hydraulic pressure, or by pumping. The solvent drained from the item may be assisted by air, compressed gas, hydraulic pressure or by pumping. Hand-wipe cleaning operation where wiping, scrubbing, mopping, or other hand actions are used are not included in this definition. Flush cleaning does not include spray gun cleaning. Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired, with the regard to a unit, means the combustion of fossil fuel, alone or in combination with any other fuel, where fossil fuel is projected to comprise more than 50 percent of the annual heat input. Fountain solution means the solution which is applied to the image plane to maintain the hydrophilic properties of the nonimage areas. It is primary water containing an etchant, a gum arabic and a dampening aid (commonly containing alcohol and alcohol substitutes). Freeboard area means the air space in a batch-load cold cleaner that extends from the liquid surface to the top of the tank. Freeboard height: (1) The distance from the top of the solvent to the top of the tank for batch-loaded cold cleaners; (2) The distance from the air-vapor interface to the top of the tank for open-top vapor degreasers; or (3) The distance from either the air-solvent or air-vapor interface to the top of the tank for conveyorized degreasers. Freeboard ratio means the freeboard height divided by the smaller of either the inside length or inside width of the degreaser. Friable asbestos-containing material means any material that contains more than one percent, as determined by either the method specified in appendix E, section 1 Polarized Light Microscopy in 40 CFR 61, subpart M or EPA/600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials, asbestos that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure. Fugitive emissions means those emissions which, according to good engineering practice, could not pass through a stack, chimney, vent or other functionally equivalent opening. Furnishings means removable furniture, drapes, rugs and decorative items. Gaseous fuel means a combustible gas that includes, but is not limited to, natural gas, landfill gas, coal-derived gas, refinery gas, and biogas. Blast furnace gas is not considered a gaseous fuel under this definition. Gasoline means a petroleum liquid having a Reid vapor pressure of four pounds per square inch (4 PSI) or greater. Gasoline dispensing facility means any stationary facility which dispenses gasoline into the fuel tank of a motor vehicle. Gasoline distribution facility means any stationary facility which transfers, loads, and/or unloads gasoline, including but not limited to gasoline bulk terminals, bulk plants, and pipeline facilities, that also does not meet the definition of a gasoline dispensing facility. Glove bag means a manufactured or fabricated device, typically constructed of six mil transparent polyethylene or polyvinyl chloride plastic. This device consists of two inward projecting tong sleeves, an internal tool pouch and an attached, labeled receptacle for asbestos waste. The bags are especially designed to contain sections of pipe for the purpose of removing a short length of damaged asbestos material without releasing fibers into the air. Good engineering practice (GEP) stack height means the greater of: (1) Sixty-five meters measured from the ground-level elevation at the base of the stack; (2) For stacks on which construction commenced on or before January 12, 1979 and for which the owner or operator had obtained all applicable permits or approvals required under 40 CFR parts 51 and 52, Hg = 2.5H provided the owner or operator produces evidence that this equation was actually relied on in establishing an emission limitation, and for all other stacks, Hg = H = 1.5L Where: Hg = GEP stack height, measured from the ground-level elevation at the base of the stack, H = height of nearby structure(s) measured from the ground level elevation at the base of the stack; and L = lesser dimension, height or projected width of the nearby structure(s). Provided that the director may require the use of a field study or fluid model to verify GEP stack height for the installation; or (3) The height demonstrated by a fluid model or field study approved by the director, which ensures that the emissions from a stack do not result in excessive concentrations of any air pollutant as a result of atmospheric downwash, wakes or eddy effects created by the source itself, nearby structures or nearby terrain features. Ground-level ozone means a colorless, odorless gas formed by the mixing of volatile organic compounds and oxides of nitrogen from stationary and mobile pollution sources in the presence of heat and sunlight. Ground-level ozone is a strong oxidizer that negatively affects human health by causing diminished lung function in both healthy individuals and those with pre-existing respiratory problems. Gravure, intaglio printing process means the images are made up of tiny depressions or cells into the surface of the design cylinder. Liquid ink is flowed into the cells while excess ink is scraped from the surface of the cylinder. The cylinder is pressed against the substrate where the ink is transferred from the cells. Hand cleaning/wiping operation means the removal of contaminants, such as dirt, grease, oil and coatings, from a surface by physically rubbing it with a material such as a rag, paper or cotton swab that has been moistened with a cleaning solvent. Hazardous air pollutant means any air pollutant listed in the Environmental Protection Agency list of hazardous air pollutants with modifications. Hearing means any presentation to, or consideration by, the hearing officer of evidence or argument on a petition seeking the commission's review of an action by the department. Heat input means the product (in mmBTU/time) of the gross calorific value of the fuel (in BTU/lb.) and the fuel feed rate into a combustion device (in mass of fuel/time), as measured, recorded, and reported to the administrator by the NOx authorized account representative and as determined by the administrator in accordance with the approved process, and does not include the heat derived from preheated combustion air, recirculated flue gases, or exhaust from other sources. Heatset means a class of web-offset lithographic and letterpress printing in which the setting of the printing inks requires a heated dryer to evaporate the ink oils. The setting or curing of inks using only radiation (e.g., infrared, ultraviolet light, or electron beam) is not heatset and is classified as nonheatset. High efficiency particulate air filter (HEPA) means a HEPA filter found in respirators and vacuum systems capable of filtering 0.3 micron particles with at least 99.97 percent efficiency. High terrain means any area having an elevation 900 feet or more above the base of the stack of the installation. Homogeneous area means an area of surfacing material, thermal system insulation material or miscellaneous material that is uniform in color and texture. Hospital/medical/infectious waste incinerator (HMIWI) or HMIWI unit means any device that combusts any amount of hospital waste and/or medical/infectious waste. Household waste means any solid waste (including garbage, trash, and sanitary waste in septic tanks) derived from households (including, but not limited to, single and multiple residences, hotels and motels, bunkhouses, ranger stations, crew quarters, campgrounds, picnic grounds, and day-use recreation areas). Idling means the operation of an engine where the engine is not engaged in gear. Imminent health hazard means a significant threat or danger to health that is considered to exist when there is evidence sufficient to show that a product, practice, circumstance, or event creates a situation that requires immediate correction or cessation of operation to prevent illness or injury based on the following: Number of potential illnesses or injuries; • Nature, severity, and duration of the anticipated illness or injury; • Effect on the environment or the surrounding geographical area. Incinerator means any article, machine, equipment, contrivance, structure or part of a structure used to burn refuse or to process refuse material by burning other than by open burning as defined herein. Indirect heating source means a source operation in which fuel is burned for the primary purpose of producing steam, hot water or hot air, or other indirect heating of liquids, gases or solids where, in the course of doing so, the products of combustion do not come into direct contact with process materials. Ink formulation as applied means the base graphic arts coating and any additives such as thinning solvents to make up the ink material that is applied to a substrate. Innovative control technology means any system of air pollution control that has not been adequately demonstrated in practice but would have a substantial likelihood of achieving greater continuous emission reduction than any control system in current practice or of achieving at least comparable reductions at lower cost in terms of energy, economics, or non-air-quality environmental impacts. Insignificant activity means an activity or emission unit in which the only applicable requirement would be to list the requirement in an operating permit application under 10 CSR 10-6.065 (Operating Permits) and is either of the following: (1) Emission units whose aggregate emission levels for the installation do not exceed that of the de minimis levels; and (2) Emission units or activities listed in section 8-10 as exempt or excluded from construction permit review. Inspector means an individual, under AHERA, who collects and assimilates information used to determine whether asbestos-containing material is present in a building or other air contaminant sources. Installation. (1) For asbestos projects, any building or structure, or any group of buildings or structures, at a single demolition or renovation site that are under the control of the same owner or operator (or owner or operator under common control); and (2) For all other purposes, all source operations including activities that result in fugitive emissions, that belong to the same industrial grouping (that have the same two-digit code as described in the Standard Industrial Classification Manual, 1987), and any marine vessels while docked at the installation, located on one or more contiguous or adjacent properties and under the control of the same person (or persons under common control). Institutional cleaning means cleaning activities conducted at organizations, societies or corporations including but not limited to schools, hospitals, sanitariums and prisons. Interior body spray (two- and three-piece) means the surface coating for the interior and ends of a two-piece formed can or the surface coating of the side of the rectangular material to be used as the interior and ends of a three-piece can. Internal combustion engine means any engine in which power, produced by heat and/or pressure developed in the engine cylinder(s) by burning a mixture of fuel and air, is subsequently converted to mechanical work by means of one or more pistons. Internal floating roof means a product cover in a fixed roof tank which rests upon or is floated upon the volatile organic compound (VOC) liquid being contained and which is equipped with a sliding seal(s) to close the space between the edge of the covers and tank shell. Inventory means a quantification of emissions by installation and by source operation. Janitorial cleaning means the cleaning of building or facility components such as the floors, ceilings, walls, windows, doors, stairs, bathrooms, kitchens, etc. in nonmanufacturing areas. Kansas City Metropolitan Area means the geographical area comprised of Jackson, Cass, Clay, Platte, Ray and Buchanan Counties. Lacquers means a surface coating that is basically solutions of nitrocellulose in volatile organic compounds (VOC), with plasticizers and other resins added to improve the quality of the film. Landfill means an area of land of an excavation in which wastes are placed for permanent disposal, and that is not a land application unit, surface impoundment, injection well, or waste pile as those terms are defined under 40 CFR 257.2. Letterpress printing means a printing process in which the image area is raised relative to the nonimage area, and the ink is transferred to the substrate directly for the image surface. Light-duty truck (LDT) means any motor vehicle rated at 8,500 pounds gross weight or less, and which has a basic vehicle frontal area of 45 square feet or less, which is: (1) Designed primarily for purposes of transportation of property or is a derivation of such a vehicle; (2) Designed primarily for transportation of persons and has a capacity of more than 12 persons; or (3) Available with special features enabling off-street or off-highway operation and use. Liquefied cutback asphalt means an asphalt cement which has been liquefied by blending with petroleum solvents (diluents). Liquid fuel means a combustible liquid that includes, but is not limited to, distillate oil, residual oil, waste oil, and process liquids. Liquid-mounted seal means a primary foam or liquid-filled seal mounted in continuous contact with the liquid between the wall of the storage vessel and the floating roof around the circumference of the tank. Lithographic printing means a planographic printing process where the image and nonimage areas are chemically differentiated; the image area is oil receptive and the nonimage area is water receptive. This method differs from other printing methods, where the image is typically printed from a raised or recessed surface. Offset lithographic printing is the only common type of lithographic printing used for commercial printing. Lithography uses the planographic method where the image and nonimage areas are on the same surface plane. The image carrier is chemically treated so that the image will accept ink and the nonimage areas will accept water (dampening solution). Based on the principle, "grease and water do not mix." The inked image carrier, or plate, is pressed against a rubber blanket where the ink is transferred. Then the rubber blanket is pressed against the substrate to transfer the inked image. Both sheetfed and web fed offset lithographic presses are used. There are two basic types of lithographic paste inks: non-heatset inks which include sheetfed inks (cure by oxidation and polymerization) and non-heatset web offset ink (absorption) and heatset web offset inks (dry by evaporation). Lower explosive limit (LEL) means the lower limit of flammability of a gas or vapor at ordinary ambient temperatures expressed in percent of the gas or vapor in air by volume. Lowest achievable emission rate (LAER) means that rate of emissions which reflects: (1) The most stringent emission limitation which is contained in any state implementation plan for a class or category of source, unless the owner or operator of the proposed source demonstrates that such limitations are not achievable; or (2) The most stringent emission limitation which is achieved in practice by the class or category of source, whichever is more stringent. LAER shall not be less stringent than the new source performance standard limit. Magnet wire coating means the process of applying a coating of electrically insulating varnish or enamel to aluminum or copper wire for use in electrical machinery. Major modification means any physical change or change in the method of operation at an installation, or in the attendant air pollution control equipment that would result in a significant net emissions increase of any pollutant A physical change or a change in the method of operation, unless previously limited by enforceable permit conditions, shall not include: (1) Routine maintenance, repair, and replacement of parts; (2) Use of an alternative fuel or raw material by reason an order under sections 2(a) and (b) of the Energy Supply and Environmental Coordination Act of 1974, a prohibition under the Power Plant and Industrial Fuel Use Act of 1978 or by reason of a natural gas curtailment plan pursuant to the Federal Power Act; (3) Use of an alternative fuel or raw material, if prior to January 6, 1975 the source was capable of accommodating the fuel or material, unless the change would be prohibited under any enforceable permit condition which was established after January 6, 1975; (4) An increase in the hours of operation or in the production rate unless the change would be prohibited under any enforceable permit condition which was established after January 6, 1975; or (5) Use of an alternative fuel by reason of an order or rule under section 125 of the Clean Air Act. Malfunction means a sudden and unavoidable failure of air pollution control equipment or process equipment or of a process to operate in a normal and usual manner. Excess emissions caused by improper design shall not be deemed a malfunction. Material safety data sheet (MSDS) means the chemical, physical, technical, and safety information document supplied by the manufacturer of the coating, solvent, or other chemical product. Maximum achievable control technology (MACT) means the maximum degree of reduction in emissions of the hazardous air pollutants as listed in this section of the Code (including a prohibition on these emissions where achievable) that the administrator, taking into consideration the cost of achieving such emissions reductions and any non-air quality health and environmental impacts and requirements, determines is achievable for new or existing sources in the category or subcategory to which this emission standard applies, through application of measures, processes, methods, systems, or techniques including, but not limited to, measures which: (1) Reduce the volume of or eliminate emissions of pollutants through process changes, substitution of materials, or other modifications; (2) Enclose systems or processes to eliminate emissions; (3) Collect, capture or treat such pollutants when released from a process, stack, storage, or fugitive emissions point; (4) Are design, equipment, work practice or operational standards (including requirements for operational training or certification); or (5) Are a combination of the above points. Maximum design heat input means the ability of a unit to combust a stated maximum amount of fuel per hour on a steady state basis, as determined by the physical design and physical characteristics of the unit. Maximum rated hourly heat input means a unit-specific maximum hourly heat input (mmBTU) which is the higher of the manufacturer's maximum rated hourly heat input or the highest observed hourly heat input. Metal furniture coating means the surface coating of any furniture made of metal or any metal part which will be assembled with other metal, wood, fabric, plastic or glass parts to form a furniture piece. Modification. (1) For the purposes of restriction of emissions from municipal solid waste landfills, modification is an increase in the permitted volume design capacity of the landfill by either horizontal or vertical expansion based on its most recent permitted design capacity; modification does not occur until the owner or operator commences construction on the horizontal or vertical expansion; (2) For the purpose of restriction of emission of odors, modification is any change to a source of odor emissions or source operations, including odor controls, that causes or could cause an increase in potential odor emissions; (3) For all other purposes, modification means any physical change to, or change in method of operation of, a source operation or attendant air pollution control equipment which would cause an increase in potential emissions of any air pollutant emitted by the source operation. Modification, title I. See "title I modification." Monitoring system means any monitoring system that meets the requirements as described in a specific rule, including a continuous emissions monitoring system, an excepted monitoring system, or an alternative monitoring system. Monthly throughput means the total volume of gasoline that is loaded into all gasoline storage tanks during a month, as calculated on a rolling 30-day average. Motorcycle means a motor vehicle operated on two wheels. Motor tricycle means a motor vehicle operated on three wheels, including a motorcycle with any conveyance, temporary or otherwise, requiring the use of a third wheel. Motor vehicle means any self-propelled vehicle. Motor vehicle deadener means a coating, used at an installation that is not an automobile or light duty truck assembly coating installation, applied to selected motor vehicle surfaces primarily for the purpose of reducing the sound of road noise in the passenger compartment. Nameplate capacity means the maximum electrical generating output (expressed as megawatt) that a generator can sustain over a specified period of time when not restricted by seasonal or other deratings, as listed in the National Allowance Data Base (NADB) under the data field "NAMECAP" if the generator is listed in the NADB or as measured in accordance with the United States Department of Energy standards. For generators not listed in the NADB, the nameplate capacity shall be used. National Ambient Air Quality Standards (NAAQS) means those standards established pursuant to section 109 of the Act and defined by 40 CFR 50. It includes standards for carbon monoxide (CO), lead (Pb), nitrogen dioxide (NO 2 ) or oxides of nitrogen (NOx), ozone, particulate matter (PM10 and PM2.5), and sulfur dioxide (SO 2 ) or sulfur oxides (SOx). Named installations means the following which are named installations. (1) Coal cleaning plants (with thermal dryers). (2) Kaft pulp mills. (3) Portland cement plants. (4) Primary zinc smelters. (5) Iron and steel mills. (6) Primary aluminum ore reduction plants. (7) Primary copper smelters. (8) Municipal incinerators capable of charging more than 250 tons of refuse per day. (9) Hydrofluoric, sulfuric, or nitric acid plants. (10) Petroleum refineries. (11) Lime plants. (12) Phosphate rock processing plants. (13) Coke oven batteries. (14) Sulfur recovery plants. (15) Carbon black plants (furnace process). (16) Primary lead smelters. (17) Fuel conversion plants. (18) Sintering plants. (19) Secondary metal production plants. (20) Chemical process plants. (21) Fossil-fuel boilers (or combination thereof) totaling more than 250 million British thermal units per hour heat input. (22) Petroleum storage and transfer facilities with a capacity exceeding 300,000 barrels. (23) Taconite ore processing facilities. (24) Glass fiber processing plants. (25) Charcoal production facilities. (26) Fossil-fuel-fired steam electric plants of more than 250 million British thermal units per hour heat. (27) All other stationary source categories regulated by a standard promulgated under section 111 or 112 of the Act, but only with respect to those air pollutants that have been regulated for that category. Nearby means nearby, as used in the definition "good engineering practice (GEP) stack height" point (2) in this section, is defined for a specific structure or terrain feature: (1) For purposes of applying the formula provided in definition of "good engineering practice (GEP) stack height" point (2) in this section, nearby means that distance up to five times the lesser of the height or the width dimension of a structure, but not greater than one-half mile; (2) For conducting fluid modeling or field study demonstrations under subparagraph the definition "good engineering practice (GEP) stack height" point (3) in this section. "Nearby" means not greater than one-half mile, except that the portion of a terrain feature may be considered to be nearby which falls within a distance of up to ten times the maximum height of the feature, not to exceed two miles if feature achieves a height one-half mile from the stack that is at least 40 percent of the GEP stack height determined by the formula provided in the definition "good engineering practice (GEP) stack height" point (2) in this section, or 26 meters, whichever is greater, as measured from the ground-level elevation at the base of the stack. The height of the structure or terrain feature is measured from the ground-level elevation at the base of the stack. Net emissions increase. This term is defined in 40 CFR 52.21(b)(3), promulgated as of July 1, 2003, and hereby incorporated by reference in this rule, as published by the Office of the Federal Register, U.S. National Archives and Records, 700 Pennsylvania Avenue NW, Washington, DC 20408. This rule does not incorporate any subsequent amendments or additions. New. Defined as follows: (1) For the purpose of restriction of particulate matter emissions from fuel burning equipment used for indirect heating, any source which is not permanently shutdown or an existing source as defined in point (1) of "existing" definition in this section; and (2) For all other purposes, any source which is not permanently shutdown or an existing source as defined in point (2) of "existing" definition in this section. NIOSH means the National Institute of Occupational Safety and Health. Nonaqueous solvent means any solvent not classifiable as an aqueous solvent as defined by a solvent in which water is the primary ingredient (greater than 80 percent by weight or greater than 60 percent by volume of solvent solution as applied must be water). Aqueous solutions must have a flash point greater than 93 degrees Celsius (200 degrees Fahrenheit) (as reported by the manufacturer) and the solution must be miscible with water. Nonattainment area (NAA) means any geographic area of the United States which has been designated as nonattainment under section 107 of the Clean Air Act and described in 40 CFR 81. Nonpermanent final finish means a material such as a wax, polish, nonoxidizing oil, or similar substance that must be periodically reapplied to a surface over its lifetime to maintain or restore the reapplied material's intended effect. Offset means a decrease in actual emissions from source operation or installation which is greater than the amount of emissions anticipated from a modification or construction of a source operation or installation. The decrease must be of the same pollutant and have substantially similar environmental and health effects on the impacted area. Any ratio of decrease to increase greater than 1:1 constitutes offset. The exceptions to this are ozone nonattainment areas where volatile organic compound (VOC) and oxides of nitrogen (NOx) emissions will require an offset ratio of actual emission reduction to new emissions according to the following schedule: marginal area = 1.1:1; moderate area = 1.15:1, serious area = 1.2:1 severe area = 1.3:1 and extreme area 1.5:1. Offset lithographic printing means the process that transfer from a plate to a rubber blanket cylinder before transfer to the substrate surface to be printed. Opacity means the extent to which airborne material obstructs the transmission of incident light and obscures the visual background. Opacity is stated as a percentage of light obstructed and can be measured by a continuous opacity monitoring system or a trained observer. An opacity of 100 percent represents a condition in which no light is transmitted, and the background is completely obscured. Open burning means the burning of any materials where air contaminants resulting from combustion are emitted directly into the ambient air without passing through a stack or chimney from an enclosed chamber. For the purposes of this definition, a chamber shall be regarded as enclosed, when during the time combustion takes place, only such apertures, ducts, stacks, flues, or chimneys, as are necessary to provide combustion air and to permit the escape of exhaust gases are open. Open-top vapor degreaser means a type of degreaser which consists of a tank where solvent is heated to its boiling point which creates a zone of solvent vapor contained by a set of cooling coils. Condensation of the hot solvent vapor cleans or degreases the colder metal parts. Operator means an entity that is legally responsible for the operation of a facility in any way or is legally responsible for the renovation, demolition, or abatement of a facility. Pail means any nominal cylindrical container of one- to 12-gallon capacity. Paint means a pigmented surface coating using volatile organic compounds (VOCs) as the major solvent and thinner which converts to a relatively opaque solid film after application as a thin layer. Part 70 means the Environmental Protection Agency regulations, codified at 40 CFR 70 setting forth requirements for state operating permit programs pursuant to title V of the Act. Particulate matter means any material, except uncombined water, that exists in a finely divided form as a liquid or solid and as specifically defined as follows: (1) For purposes of ambient air concentrations: (a) PM: Any airborne, finely-divided solid or liquid material with an aerodynamic diameter smaller than 100 micrometers as measured in the ambient air as specified in 10 CSR 10-6.040(4)(B); (b) PM10: Particulate matter with an aerodynamic diameter less than or equal to a nominal ten micrometers as measured in the ambient air as specified in 10 CSR 10-6040(4)(J); (c) PM2.5: Particulate matter with an aerodynamic diameter less than or equal to a nominal 2.5 micrometers including the filterable component as measured in the ambient air as specified in in 10 CSR 10-6040(4)(L); (2) For the purpose of hospital, medical, infectious waste incinerators, total particulate matter emitted from a hospital medical infectious waste incinerator as measured by EPA Method 5 of 40 CFR 60, appendix A-3 or EPA Method 29 of 40 CFR 60, appendix A-8; and (3) For all other purposes: (a) Condensable particulate matter (PM): Material that is vapor phase at stack conditions, but condenses and/or reacts upon cooling and dilution in the ambient air to form solid or liquid PM immediately after discharge from the stack. Note that all condensable PM is assumed to be in the PM2.5 size fraction; (b) Filterable PM: Particles that are emitted directly by a source as a solid or liquid at stack or release conditions and captured on the filter of a stack test train; (c) Primary PM (Also known as direct PM): Particles that enter the atmosphere as a direct emission from a stack or an open source. Primary PM has two components: filterable PM and condensable PM. These two PM components have no upper particle size limit; (4) Primary PM2.5 (also known as direct PM2.5, total PM2.5, PM2.5, or combined filterable PM2.5 and condensable PM): PM with an aerodynamic diameter less than or equal to two and five-tenths (2.5) micrometers. These solid particles are emitted directly from an air emissions source or activity, or are the gaseous or vaporous emissions from an air emission source or activity that condense to form PM at ambient temperatures. Direct PM2.5 emissions include elemental carbon, directly emitted organic carbon, directly emitted sulfate, directly emitted nitrate, and other inorganic particles (including but not limited to crustal material, metals, and sea salt); and (5) Primary PM10 (also known as direct PM10, total PM10, PM10, or the combination of filterable PM10 and condensable PM): PM with an aerodynamic diameter equal to or less than ten micrometers. Permanent shutdown means the permanent cessation of operation of any air pollution control equipment or process equipment, not to be placed back into service or have a start-up. Permitting authority means either the administrator or the state air pollution control agency, local agency, or other agency authorized by the administrator to carry out a permit program as intended by the Act. Person means any individual, partnership, association, corporation, association, firm, company, public or private corporation including the parent company of a wholly-owned subsidiary, joint stock company, municipality, political subdivision, agency, board, department or bureau of the state or federal government, trust, estate or other legal entity either public or private which is recognized by law as the subject of rights and duties. This shall include any legal successor, employee or agent of the previous entities. Person in charge means the individual present at a facility or work site who is responsible for the operation at the time of inspection. Petroleum liquid means petroleum, condensate and any finished or intermediate products manufactured in a petroleum refinery with the exception of numbers 2—6 fuel oils as specified in ASTM D 396-13, gas turbine fuel oils number 2-GT-4-GT, as specified in ASTM D 2880-13, and diesel fuel oils number 2-D and 4-D as specified in ASTM D 975-13. Petroleum refinery means any facility which produces gasoline, kerosene, distillate fuel oils, residual fuel oils, lubricants or other products through distillation, cracking, extraction or reforming of unfinished petroleum derivatives. Pharmaceutical means any compound or preparation included under the Standard Industrial Classification Codes 2833 (Medicinal Chemicals and Botanical Products), and 2834 (Pharmaceutical Preparations), excluding products formulated by fermentation, extraction from vegetable material or animal tissue or formulation and packaging of the final product. Pilot plants means the installations which are of new type or design which will serve as a trial unit for experimentation or testing. Place of public accommodation means any place or business offering or holding out to the general public goods, services, privileges, facilities, advantages or accommodations for the peace, comfort, health, welfare, and safety of the general public. Plant-mix means a mixture produced in an asphalt mixing plant that consists of mineral aggregate uniformly coated with asphalt cement, cutback asphalt or emulsified asphalt. Pollutant means an air contaminant listed in this section under the definition of "de minimis levels" without regard to levels of emission or air quality impact. Polyethylene bag sealing operation means any operation or facility engaged in the sealing of polyethylene bags, usually by the use of heat. Polystyrene resin means the product of any styrene polymerization process, usually involving heat. Porous material means a substance that has tiny openings, often microscopic, in which fluids may be absorbed or discharged, including, but not limited to, paper and corrugated paperboard. Portable equipment means any equipment that is designed and maintained to be movable, primarily for use in noncontinuous operations. Portable equipment includes rock crushers, asphaltic concrete plants and concrete batch plants. Portland cement means a hydraulic cement produced by pulverizing clinker consisting essentially of hydraulic calcium silicates, usually containing one or more of the forms of calcium sulfate as an interground addition. Portland cement kiln means a system, including any solid, gaseous, or liquid fuel combustion equipment, used to calcine and fuse raw materials, including limestone and clay, to produce Portland cement clinker. Potential to emit means the emission rates of any pollutant at maximum design capacity. Annual potential shall be based on the maximum annual-rated capacity of the installation assuming continuous year-round operation. Federally enforceable permit conditions on the type of materials combusted or processed, operating rates, hours of operation, and the application of air pollution control equipment shall be used in determining the annual potential. Secondary emissions do not count in determining annual potential. PPMV means, for medical waste and solid waste incinerators, parts per million by dry volume. For sewage sludge and industrial waste incinerators, PPMV means parts per million by volume corrected to seven percent oxygen. Precursors of a criteria pollutant are: (1) For ozone, nitrogen oxides (NOx), unless an area is exempted from NOx requirements under section 182(f) of the Clean Air Act, and volatile organic compounds (VOCs); (2) For PM10, those pollutants described in the PM10 nonattainment area applicable state implementation plan as significant contributors to the PM10 levels; and (3) For PM2.5: (a) Sulfur dioxide (SO 2 ) in all PM2.5 nonattainment and maintenance areas; (b) NOx in all PM2.5 nonattainment and maintenance areas unless both the state and U.S. Environmental Protection Agency (EPA) determine that it is not a significant precursor; and (c) VOC and ammonia (NH3) only in PM2.5 nonattainment or maintenance areas where either the state or EPA determines that they are significant precursors. Premises means a lot, plot or parcel of land, the improvements thereon and the ambient air above such land or improvements. Primary aluminum reduction installation means any facility manufacturing aluminum by electrolytic reduction of alumina. Primer means the first layer and any subsequent layers of identically formulated coating applied to the article to provide corrosion resistance, surface etching, surface leveling, adhesion promotion, or other property depending on the end use or exposure of the final product. Primers that are defined as specialty coatings are not included under this definition. Primer-surfacer means an intermediate protective coating applied over the electrodeposition primer and under the topcoat at an automobile or light-duty truck assembly coating facility. Primer-surfacer provides adhesion, protection, and appearance properties to the total finish. "Primer-surfacer" may also be called guide coat or surfacer. Process or production unit means, for the purpose of section 8-10(I), Hazardous air pollutants permits, any collection of structures and/or equipment, that processes, assembles, applies, or otherwise uses material inputs to produce or store an intermediate or final product. A single facility may contain more than one process or production unit. Process weight means the total weight of all materials introduced into an emission unit, including solid fuels which may cause any emission of particulate matter, but excluding liquids and gases used solely as fuels and air introduced for purposes of combustion. Production equipment exhaust system means a device for collecting and directing out of the work area fugitive emissions from reactor openings, centrifuge openings, and other vessel openings and equipment for the purpose of protecting workers from excessive exposure. Publication rotogravure printing means rotogravure printing upon paper which is subsequently formed into books, magazines, catalogues, brochures, directories, newspaper supplements, and other types of printed materials. Quantifiable means the quantity of emission reductions can be measured or estimated by accurate and replicable techniques. These techniques shall be at least as accurate and replicable as the techniques accepted by the U.S. EPA, where accepted techniques exist. Reactor means a vat or vessel, which may be jacketed to permit temperature control, designed to contain chemical reactions. Reconstruction means where the fixed capital cost of the new components exceeds 50 percent of the fixed capital cost of a comparable entirely new source operation or installation, the use of an alternative fuel or raw material by reason of an order in effect under sections 2(a) and (b) of the Energy Supply add Environmental Coordination Act of 1974, by reason of natural gas curtailment plan in effect pursuant to the Federal Power Act, or by reason of an order or rule under section 125 of the Clean Air Act, shall not be considered reconstruction. In determining whether a reconstruction will occur, the provisions of 40 CFR 60.15, December 1, 1979, shall be considered by the director. Refinery fuel gas means any gas which is generated by a petroleum refinery process unit and which is combusted, including any gaseous mixture of natural gas and fuel gas. Refuse means the garbage, rubbish, trade wastes, leaves, salvageable material, agricultural wastes or other wastes. Regulated air pollutant means all air pollutants or precursors for which any standard has been promulgated. Regulated asbestos-containing material (RACM) are one of the following: (1) Friable asbestos material; (2) Category I nonfriable ACM that has become friable; (3) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting or abrading; or (4) Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized or reduced to powder by forces expected to act on the material in the course of regulated demolition or renovation operations. Regulatory authority means the director of health or the director's authorized representative, or local, state, or federal enforcement body or authorized representative having jurisdiction. Reid vapor pressure (RVP) means the absolute vapor pressure of a petroleum liquid as determined by "Tests for Determining Reid Vapor Pressure (RVP) of Gasoline and Gasoline—Oxygenate Blends" 40 CFR Part 80, appendix E as in effect July 1, 1990. Renewal means the process by which a permit is reissued at the end of its term. Renovation means altering a facility or one or more facility components in any way, including the stripping or removal of regulated asbestos-containing material from a facility component. Repair means for the purpose of asbestos projects, the restoration of asbestos material that has been damaged. "Repair" consists of the application of rewettable glass cloth, canvas, cement or other suitable material. It may also involve filling damaged areas with nonasbestos substitutes reencapsulating or painting previously encapsulated materials. Residual fuel oil means the fuel oil variously known as Bunker C, PS 400 and Number generally used for the production of electric power, space heating, vessel bunkering, and various industrial purposes. It has a minimum flash point of 140 degrees Fahrenheit. Responsible official means one of the following: (1) The president, secretary, treasurer, or vice-president of a corporation in charge of a principal business function or any other person who performs similar policy and decision-making functions for the corporation, or a duly authorized representative of this person if the representative is responsible for the overall operation of one or more manufacturing, production, or operating facilities applying for or subject to a permit and either: (a) The facilities employ more than 250 persons or have a gross annual sales or expenditures exceeding $25,000,000.00 (in second quarter 1980 dollars); or (b) The delegation of authority to this representative is approved in advance by the permitting authority; (2) A general partner in a partnership or the proprietor in a sole proprietorship; (3) Either a principal executive officer or ranking elected official in a municipality or state, federal, or other public agency. For the purpose of this part, a principal executive officer of a federal agency includes the chief executive officer having responsibility for the overall operations of a principal geographic unit of the agency; or (4) The designated representative of an affected source in so far as actions, standards, requirements, or prohibitions under title IV of the Act or the regulations promulgated under the Act are concerned, and the designated representative for any other purposes under part 70. Retail outlet means any establishment where gasoline is sold, offered for sale or used as a motor vehicle fuel. Road-mix means an asphalt course produced by mixing mineral aggregate and cutback or emulsified asphalt at the road site by means of travel plants, motor graders, drags or special road-mixing equipment. Roll printing means the application of words, designs and pictures to a substrate usually by means of a series of hard rubber or steel rolls, each with only partial coverage. Roller spreader means the device used for the application of a coating material to a substrate by means of hard rubber or steel rolls. Rotogravure printing means the application of words, designs and pictures to a substrate by means of a roll-printing technique which involves an intaglio or recessed image areas in the form of cells. Salvage operation means any business, trade, industry or other activity conducted in whole or in part for the purpose of salvaging or reclaiming any product or material. Sealing material means for the purpose of asbestos projects, a liquid substance that does not contain asbestos which is used to cover a surface that has previously been coated with a friable asbestos-containing material for the intended purpose of preventing any asbestos fibers remaining on the surface from being dispersed into the air. This substance shall be distinguishable from the surface to which it is applied. Secondary emissions means the emissions which occur or would occur as a result of the construction or operation of an installation or major modification but do not come from the installation or major modification itself. Secondary emissions must be specific, well-defined, quantifiable and impact the same general area as the installation or modification which causes the secondary emissions. Secondary emissions may include but are not limited to: (1) Emissions from trucks, ships or trains coming to or from the installation or modification; and (2) Emissions from any off-site support source which would not be constructed or increase its emissions except as a result of the construction or operation of the major stationary source or major modification. Sewage sludge incinerator means any incinerator used to reduce the quantity of sewage sludge. Sheet basecoat means the roll coated primary interior surface coating applied to surfaces for the basic protection of buffering filling material from the metal can surface. Sheet-fed means a printing press where individual sheets of substrate are fed into the press sequentially. Shower room means, for the purpose of asbestos projects, A room between the clean room and the equipment room in the work decontamination enclosure. This room shall be equipped with running hot and cold water that is suitably arranged for complete showering during decontamination. Shutdown means the cessation of operation of any air pollution control equipment or process equipment, except the routine phasing out of process equipment. Side-seam coating means a coating applied on the interior and/or exterior of a welded, cemented, or soldered seam to protect the exposed metal. Significant means a net emissions increase or potential to emit at a rate equal to or exceeding the de minimis levels or create an ambient air concentration at a level greater than those listed table 4 (significant levels for air quality impact in class II areas) in section 8-10.(K), or any emissions rate or any net emissions increase associated with an installation subject to section 8-10 which would be constructed within ten kilometers of a class I area and have an air quality impact on the area equal to or greater than one micro-gram per cubic meter (24-hour average). For purposes of new source review under sections 8-10.(g) and 8-10 (h) net emission increases of hazardous air pollutants exceeding the de minimis levels are considered significant only if they are also criteria pollutants. Six-minute period means a 360-consecutive-second time interval. Six-minute block averages shall be utilized for continuous opacity monitoring system data per the provisions of appendix B to 40 CFR 60, Performance Specification 1, promulgated as of July 1, 2007, and hereby incorporated by reference in this rule, as published by the U.S. Government Printing Office, 732 N Capitol Street NW, Washington, DC 20401. Sludge means any solid, semisolid, or liquid waste generated from a municipal, commercial, or industrial wastewater treatment plant, water supply treatment plant, or air pollution control facility, exclusive of the treated effluent from a wastewater treatment plant. Smoke means small gas-borne particles resulting from combustion, consisting of carbon, ash and other material. Smoke generating device means specialized piece of equipment which is not an integral part of a commercial, industrial, or manufacturing process and whose sole purpose is the creation and dispersion of fine solid or liquid particles in a gaseous medium. Soils includes, but is not limited to, unwanted grease, wax, grit, ash, dirt, and oil. Solid fuel means a solid material used as a fuel that includes, but is not limited to, coal, wood, biomass, tires, plastics, and other nonfossil solid materials. Solvent means organic materials which are liquid at standard conditions and which are used as dissolvers, viscosity reducers or cleaning agents. Solvent metal cleaning means the process of cleaning soils from metal surfaces by cold cleaning or open-top vapor degreasing or conveyorized degreasing. Solvent volatility means the Reid vapor pressure of the solvent. Source means any governmental, institutional, commercial, or industrial structure, installation, plant, building, or facility that emits or has the potential to emit any regulated air pollutant under the Clean Air Act (CAA). For purposes of section 502(c) of the CAA, a source, including a source with multiple units, shall be considered a single facility. Source gas volume means the volume of gas arising from a process or other source operation. Source operation. See "emission unit." Specialty coating means a coating that, even though it meets the definition of a primer, topcoat, or self-priming topcoat, has additional performance criteria beyond those of primers, topcoats, and self-priming topcoats for specific applications. These performance criteria may include, but are not limited to, temperature or fire resistance, substrate compatibility, anti-reflection, temporary protection, or marking, sealing, adhesively joining substrates, or enhanced corrosion protection. Spray gun cleaner means equipment used to clean spray guns used to apply, but not limited to, primers, paints, specialty coatings, adhesives, sealers, resins or deadeners incorporated into a product distributed in commerce. Stack means any spatial point in an installation designed to emit air contaminants into ambient air. An accidental opening such as a crack, fissure, or hole is a source of fugitive emissions, not a stack. Stage I vapor recovery system means a system used to capture the gasoline vapors that would otherwise be emitted when gasoline is transferred from a loading installation to a cargo tank or from a cargo tank to a storage tank. Stage II vapor recovery system means a system used to capture the gasoline vapors that would otherwise be emitted when gasoline is dispensed from a storage tank to the fuel tank of a motor vehicle. Stage II vapor recovery includes both stage I and stage II vapor recovery equipment and requirements, unless otherwise stated. Standard conditions means a gas temperature of 70 degrees Fahrenheit and a gas pressure of 14.7 pounds per square inch absolute (psia). Startup means the setting into operation of any air pollution control equipment or process equipment, except the routine phasing in of process equipment. State means any non-federal permitting authority, including any local agency, interstate association, or statewide program. When clear from its context, state shall have its conventional territorial definition. State implementation plan (SIP) means a series of plans adopted by the Missouri Air Conservation Commission, submitted by the director of the state department of natural resources, and approved by the administrator, detailing methods and procedures to be used in attaining and maintaining the ambient air quality standards in Missouri. Stationary source means any building, structure, facility, or installation which emits or may emit any air pollutant subject to regulation under the Clean Air Act. Building, structure, facility, or installation includes all pollutant emitting activities that are located on one or more contiguous or adjacent properties and are under common control of the same person(s). Storage tank means any tank, reservoir or vessel which is a container for liquids or gases, where no manufacturing process or part of it takes place. Structural item means roofs, walls, ceiling, floors, structural supports, pipes, ducts, fittings and fixtures that have been installed as an integral part of any structure. Submerged fill pipe means any fill pipe the discharge opening of which is entirely submerged when the liquid level is six inches above the bottom of the tank. Submerged fill pipe when applied to a tank which is loaded from the side is defined as any fill pipe the discharge opening of which is entirely submerged when the liquid level is 18 inches or twice the diameter of the fill pipe, whichever is greater, above the bottom of the tank. Substrate means the surface onto which coatings are applied (or into which coatings are impregnated). Synthesized pharmaceutical manufacturing means manufacture of pharmaceutical products by chemical synthesis. Temporary installation means an installation which operates or emits pollutants less than two years. Third party monitoring means, for the purpose of asbestos projects, air monitoring conducted by a person who is not under the direct control of the person carrying out the asbestos project and who has been selected by the owner or operator of the property on which the project is conducted. Title I modification means any modification that requires a permit 8-10.(g) and 8-10.(h), or that is subject to any requirement under 10 CSR 10-6.070 or 10 CSR 10-6.080. Ton or tonnage means any short ton (i.e., 2,000 pounds). Topcoat: (1) For the purposes of 10 CSR 10-2.205, a coating that is applied over a primer on an aerospace vehicle or component for appearance, identification, camouflage, or protection. Topcoats that are defined as specialty coatings are not included under this definition; and (2) For all other purposes, the last film building finishing material applied for the purpose of establishing the color or protective surface, or both, including groundcoat and paint sealer materials, base coat, and clear coat. Nonpermanent final finishes are not topcoats. Total fluoride means the elemental fluorine and all fluoride compounds as measured by reference methods specified in 40 CFR part 60, appendix A—Test Methods, "Method 12—Determination of Inorganic Lead Emissions from Stationary Sources" or equivalent or alternative methods. Trackout means materials (sand, gravel, stones, etc.) that adheres to a vehicle tires and is deposited onto paved public roads or shoulders. Trade waste means the solid, liquid or gaseous material resulting from construction or the pursuit of any business, trade or industry, or any demolition operation, including but not limited to plastics, cardboard cartons, grease, oil, chemicals or cinders. Transfer efficiency (TE) means ratio of the amount of coating solids transferred onto a product to the total of coating solids used. In any surface coating operation, TE is the ratio of solids in a coating that adhere on a target surface to the total solids used in the process for coating the target surface. Treated wood means wood that has been subjected to a chemical process or application. True vapor pressure means the equilibrium partial pressure exerted by a petroleum liquid as determined in American Petroleum Institute Bulletin 2517, Evaporation Loss from Floating Roof Tanks, 1962. Uncombined water means the visible condensed water which is not bound, physically or chemically, to any air contaminant. Unit means a fossil fuel-fired combustion device such as a stationary boiler, combustion turbine, or combined cycle system. Unit turnaround means the procedure of shutting a refinery process unit down to do necessary maintenance and repair work and putting the unit back on stream. Unit walk through monitoring means the system for monitoring volatile organic hydrocarbons which utilizes a portable hydrocarbon monitor to measure ambient hydrocarbon levels in the areas of all process equipment. Untreated wood means lumber and other wooden materials that have not been chemically treated for resistance to moisture, fire, fungi, insects, and other pests, or has not otherwise been treated or manufactured with chemicals, or that does not contain adhesives or resins. Untreated wood does not include plywood, particleboard, chipboard, and wood with other-than-insignificant quantities of paint, coating, or finish. Vapor-mounted seal means a primary seal mounted so there is an annular vapor space underneath the seal. The annular vapor space is bounded by the bottom of the primary seal, the tank wall, the liquid surface, and the floating roof. Vapor recovery system means a vapor gathering system capable of collecting the hydrocarbon vapors and gases discharged and a vapor disposal system capable of processing such hydrocarbon vapors and gases so as to limit their emission to the atmosphere. Vapor recovery system modification means any repair, replacement, alteration, or upgrading of stage I to stage II vapor recovery control equipment or gasoline dispensing equipment with stage II vapor recovery beyond normal maintenance of the system as permitted by the staff director. Vapor tight. When applied to a delivery vessel or vapor recovery system as one that sustains a pressure change of no more than 750 pascals (three inches of H 2 O) in five minutes when pressurized to a gauge pressure of 4,500 pascals (18 inches of H 2 O) or evacuated to a gauge pressure of 1,500 pascals (six inches of H 2 O). Varnish means an unpigmented surface coating containing volatile organic compounds (VOCs) and composed of resins, thinners, and driers used to give a glossy surface to wood, metal, etc. Vehicle means any mechanical device on wheels, designed primarily for use on streets, roads or highways, except those propelled or drawn by human or animal power or those used exclusively on fixed rails or tracks. Vinyl coating means a functional, decorative or protective topcoat, or printing applied to vinyl-coated fabric or vinyl sheet. Visible emission means any discharge of an air contaminant, including condensable, which reduces the transmission of light or obscures the view of an object in the background. (1) Visible emissions shall be determined in accordance with 40 CFR 60, appendix A—Reference Methods, "Method 9 Visual Determination of the Opacity of Emissions from Stationary Sources." (2) Visible fugitive emissions shall be determined in accordance with 40 CFR 60, appendix A—Reference Methods, "Method 22, Visual Determination of Fugitive Emissions from Material Sources and Smoke Emissions from Flares." Volatile organic compounds (VOC) means any compound of carbon, excluding carbon monoxide, carbon dioxide, carbonic, acid, metallic carbides or carbonates, and ammonium carbonate, that participates in atmospheric photochemical reactions to produce ozone. (1) The following compounds are not considered VOCs because of their known lack of participation in the atmospheric reactions to produce ozone: CAS # | Compound 138495428 | 1,1,1,2,3,4,4,5,5,5-decafluoro-pentane (HFC 43-10mee) 431890 | 1,1,1,2,3,3,3-heptafluoro-propane (HFC 227ea) 375031 | 1,1,1,2,2,3,3-heptafluoropro-pane (n-C3F7OCH3 or HFE-7000) 690391 | 1,1,1,3,3,3-hexafluoropropane (HFC-236fa) 679867 | 1,1,2,2,3-pentafluoropropane (HFC-245ca) 24270664 | 1,1,2,3,3-pentafluoropropane (HFC-245ea) 431312 | 1,1,1,2,3-pentafluoropropane (HFC-245eb) 460731 | 1,1,1,3,3-pentafluoropropane (HFC-245fa) 431630 | 1,1,1,2,3,3-hexafluoropropane (HFC-236ea) 406586 | 1,1,1,3,3-pentafluorobutane (HFC-365mfc) 422560 | 3,3-dichloro-1,1,1,2,2-penta-fluoropropane (HCFC-225ca) 507551 | 1,3-dichloro-1,1,2,2,3-penta-fluoropropane (HCFC-225cb) 354234 | 1,2-dichloro-1,1,2-trifluoro-ethane (HCFC-123a) 1615754 | 1-chloro-1-fluorethane (HCFC-151a) 163702076 | 1,1,1,2,2,3,3,4,4-nonafluoro-4-methoxy-butane (C4F9OCH3 or HFE-7100) 163702087 | 2-(difluoromethoxymethyl)-1,1,1,2,3,3,3-heptafluoro-propane ((CF3)2CFCF2OCH3) 163702054 | 1-ethoxy-1,1,2,2,3,3,4,4,4-nonafluorobutane (C4F90C2H5 or HFE-7200) 163702065 | 2-(ethoxydifluoromethyl)-1,1,1,2,3,3,3-heptafluoro-propane ((CF3)2CFCF2OC2H5) 297730939 | 3-ethoxy-1,1,1,2,3,4,4,5,5,6,6,6-dodecafluoro-2-(trifluoro-methyl) hexane (HFE-7500) 71556 | 1,1,1-trichloroethane (methyl chloroform) 67641 | acetone 75683 | 1-chloro 1,1-difluoroethane (HCFC-142b) 75456 | chlorodifluoromethane (HCFC-22) 593704 | chlorofluoromethane (HCFC-31) 76153 | chloropentafluoroethane (CFC-115) 2837890 | 2-chloro-1,1,1,2-tetrafluo-roethane (HCFC-124) 75718 | dichlorodifluoromethane (CFC-12) 1717006 | 1,1-dichloro 1-fluoroethane (HCFC-141b) 76142 | 1,2-dichloro 1,1,2,2-tetrafluo-roethane (CFC-114) 75376 | 1,1-difluoroethane (HFC-152a) 75105 | difluoromethane (HFC-32) 74840 | ethane 353366 | ethylfluoride (HFC-161) 74828 | methane 79209 | methyl acetate 75092 | methylene chloride (dichloromethane) 98566 | parachlorobenzotrifluoride (PCBTF) 354336 | pentafluoroethane (HFC-125) 127184 | perchloroethylene (tetrachloroethylene) 359353 | 1,1,2,2-tetrafluoroethane (HFC-134) 811972 | 1,1,1,2-tetrafluoroethane (HFC-134a) 75694 | trichlorofluoromethane (CFC-11) 26523648 | 1,1,2-trichloro-1,2,2-trifluo-roethane (CFC-113) 306832 | 1,1,1-trifluoro 2,2-dichlo-roethane (HCFC-123) 420462 | 1,1,1-trifluoroethane (HFC-143a) 75467 | trifluoromethane (HFC-23) 107313 | methyl formate (HCOOCH 3 ), 132182924 | 1,1,1,2,2,3,4,5,5,5-decafluoro-3-methoxy-4-trifluoromethyl-pentane (HFE-7300) 108327 | propylene carbonate 616386 | dimethyl carbonate 29118249 | trans-1,3,3,3-tetrafluoropropene (HFO-1234ze) 1691174 | 1,1,3,3-tetrafluorodimethyl ether (HCF2OCF2H or HFE-134) 78522471 | bis (difluoromethoxy)(difluoro) methane (HCF2 OCF2 H or HFE-236cal2) 188690780 | 1,2-bis (difluoromethoxy)-1,1,2,2-tetrafluoroethane (HCF2 OCF2 CF2 OCF2 H or HFE-338pcc13) 188690779 | 1-(difluoromethoxy)-2-[(difluoromethoxy)(difluoro)methoxy]-1,1,1,2,2-tetrafluo-roethane(HCF2 OCF2 CF2 OCF2H or H-Galden 1040x or H-Galden ZT 130 (or 150 or 180)) Perfluorocarbon compounds in the following classes: 0 | Cyclic, branched or linear, completely fluorinated alkanes 0 | Cyclic, branched or linear, completely fluorinated ethers with no unsaturations 0 | Cyclic, branched or linear, completely methylated siloxanes 0 | Cyclic, branched or linear, completely fluorinated tertiary amines with no unsaturations 0 | Sulfur-containing perfluorocarbons with no unsaturations and with sulfur bonds only to carbon and fluorine VOC may be measured by a reference method, an equivalent method, an alternative method, or by procedures specified in 40 CFR 60. These methods and procedures may measure nonreactive compounds, so an owner or operator must exclude these nonreactive compounds when determining compliance. (2) The following compound(s) are considered VOC for purposes of all record keeping, emissions reporting, photochemical dispersion modeling, and inventory requirements which apply to VOC and shall be uniquely identified in emission reports but are not VOC for purposes of VOC emissions limitations or VOC content requirements. CAS # | Compound 540885 | T-butyl acetate Waste generator means the business entity that is directly responsible for the supervision of activities that result in the accumulation of friable asbestos-containing materials. Waxy, heavy pour crude oil means a crude oil with a pour point of 50 degrees Fahrenheit or higher as determined by the ASTM Standard D(97-66), Test for Pour Point of Petroleum Oils. Wet cleaning means the process of using water or other liquid and a wet brush, mop, cloth, sponge or similar wet cleaning device to completely remove any residue of asbestos-containing materials from surfaces on which they may be located. This definition does not include the use of a wet vacuum cleaner. Wetting agent means any chemical that is added to water to decrease its surface tension and allow it to spread more easily over or penetrate into friable asbestos-containing materials. Work area means a specified room or physically isolated portion of a room, other than the space enclosed within a glove bag, in which friable asbestos-containing material is required to be handled in accordance with 10 CSR 10-6.240. The area is designated as a work area from the time that the room, or portion of it, is secured and access restrictions are in place. The area remains designated as a work area until the time that it has been cleaned in accordance with any requirements applicable to these operations. Work site means land, building, facility, or other operation where regulated and/or non-regulated work is performed.
(Ord. No. 220226, § 1, 6-30-22)
Ask a question about Kansas City law
Corpus searches the Kansas City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
