Sec. 32-62. - Building service pipe.

A. The Department will specify the size, kind, and quality of the pipe which shall be installed by the applicant between the curb cock, if installed at the property line, and the location of the meter. B. The applicant's building service pipe and all connections and fixtures attached thereto shall be subject to the inspection and approval of the Department before the water will be turned on. C. The applicant's building service pipe shall be installed at least three (3) feet, six (6) inches below final grade and at least ten (10) feet in a horizontal direction from any sewer pipe or other facilities, public or private, unless otherwise specifically authorized or approved by the Department. Where a common trench is approved, the provisions of the Plumbing Code and ordinances governing sewers shall apply. D. In backfilling the trench, rock or ashes shall not be permitted within one (1) foot of the service pipe and clean soil shall be filled in to a depth of at least one (1) foot over the service pipe. E. The applicant shall install a stop and waste cock of a type approved by the Department on the building service pipe immediately inside the foundation wall of the building served, and so located as to be easily accessible to the occupants and to provide proper drainage for all of the pipelines in the building and the meter if installed in the building. If the meter is located in the building, provision for sealing the stop and waste cock must be installed. F. No fixture shall be attached to and no branch shall be made in the building service pipe between the meter and the public water main except where two (2) or more meters are on the same service (apartments, etc.). G. Any repairs, maintenance, replacement, or relocation necessary on the customer's building service pipe or fixtures in or upon the customer's premises shall be performed by the customer at the customer's expense and risk.

(Code 1988, § 32-62)

Ask a question about Lee's Summit law

Corpus searches the Lee's Summit sections it holds and shows the ones that match, with their citations. Free, no sign-in.