§ 4.220 — PI Planned Industrial District
Code of Ordinances of the City of Lee's Summit, Missouri (Codified through Ordinance No. 10423, enacted July 14, 2026 (Supp. No. 56)) · Lee's Summit Unified Development Ordinance § 4.220
Corpus is an independent public-information project, not the official City of Lee's Summit website. Stable reference: corpuslaw.us/code/4b6371ee-2e05-4d53-a84f-2fba0c6b1404
Sec. 4.220. - PI Planned Industrial District.
A. Statement of intent and purpose. The PI Planned Industrial District is established to provide for industrial uses that are fully indoor operations with outside storage only permitted within fully-screened enclosures to the rear or side lot areas. The PI District is intended to provide areas for light manufacturing uses that primarily involve finishing or assembly of previously manufactured goods. The district is also intended to provide for the location of wholesaling, distribution or warehousing uses. B. Uses. 1. Permitted principal and accessory uses, uses permitted as of right but with conditions, and special uses are contained in Table 6-1 in Article 6, Division I. 2. The PI District excludes manufacturing or industrial uses that emit noxious odors, dust, fumes, gas, noise or vibration. It also excludes hazardous materials such as those involving bulk storage of gasoline or toxic chemicals. C. Height and area regulations. 1. FAR (floor-area ratio), density and lot area/width: (See Table 6-2 in Article 6, Division I.) 2. Setback regulations, including minimum front yard, side yard and rear yard standards: (See Table 6-3 in Article 6, Division I.) 3. Height requirements: (See Table 6-4 in Article 6, Division I.) 4. Exception to the maximum height requirements is contained in Section 6.050. D. Performance and design standards. 1. Design standards are applicable to development in this district: (See Article 8, Division I.) 2. Parking regulations: (See Article 8, Division II.) 3. Sign regulations: (See Article 9.) 4. Landscaping, buffering and tree protection: (See Article 8, Division III.) 5. This district is designed for industrial and warehousing uses that do not have a detrimental effect upon adjoining residential, office or commercial development. 6. Physical appearance. a. All operations shall be carried on within an enclosed building except that new finished products or equipment in operable condition may be stored outside only within fully-screened enclosures to the rear or side lot areas. b. Normal daily wastes of an inorganic nature may be stored in containers not in a building when such containers are screened from view. c. All company service vehicles, fleet trucks, etc., used in conjunction with a permitted use shall be stored overnight such that they are screened with a landscape buffer, or are not visible from a public street. 7. Performance standards. a. Fire hazard. All flammable substances involved in any activity established in this district shall be handled in conformance with the latest edition of the Uniform Fire Code published by the American Insurance Association and applicable codes and ordinances. b. Noise. No operation shall be carried on which involves noise in excess of the normal traffic noise of the adjacent street at the time of the daily peak hour of traffic volume. Noise shall be measured at the property line and when the level of such noise cannot be determined by observation with the natural senses, a suitable instrument may be used and measurement may include breakdowns into a reasonable number of frequency ranges. All noise shall be muffled so as not to be objectionable due to intermittence, beat frequency or shrillness. c. Sewage and other liquid waste. No operation shall be carried on which involves the discharge into a sewer, water course, or the ground of liquid wastes of any radioactive nature or liquid waste of a chemical nature which are detrimental to normal sewage plant operation or corrosive and damaging to sewer pipes and installations. d. Air contaminants. (1) Air contaminants and smoke shall be less dark than designated Number One on the Ringleman Chart as published by the United States Bureau of Mines, except that smoke of a density designated as Number One shall be permitted for one four-minute period in each one-half hour. Light colored contaminants of such an opacity as to obscure an observer's view to a degree equal to or greater than the aforesaid shall not be permitted. (2) Particulate matter of dust as measured at the point of emission by any generally accepted method shall not be emitted in excess of two-tenths grain per cubic foot as corrected to a temperature of 500 degrees Fahrenheit, except for a period of four minutes in any one-half hour, at which time it may equal but not exceed six-tenths grains per cubic foot as corrected to a temperature of 500 degrees Fahrenheit. (3) Due to the fact that the possibilities of air contamination cannot reasonably be comprehensively covered in this section, there shall be applied the general rule that there shall not be discharged from any sources whatsoever such quantities of air contaminants or other materials in such quantity as to cause injury, detriment, nuisance or annoyance to any considerable number of persons or to the public in general or to endanger the comfort, repose, health or safety of any such considerable number of persons or the public in general or to cause or have a natural tendency to cause injury or damage to business, vegetation or property. e. Odor. The emission of odors that are generally agreed to be obnoxious to any considerable number of persons shall be prohibited. Observations of odor shall be made at the property line of the establishment causing the odor. As a guide to classification of odor, it shall be deemed that strong odors of putrefaction and fermentation tend to be obnoxious and that such odors as associated with baking or the roasting of nuts and coffee shall not normally be considered obnoxious within the meaning of this chapter. f. Gasses. The gasses sulfur dioxide and hydrogen sulfide shall not exceed five parts per million. All nitrous fumes shall not exceed one part per million. Measurements shall be taken at the property line of the particular establishment involved. g. Vibration. All machines including punch presses and stamping machines shall be so mounted as to minimize vibration, and in no case shall such vibration exceed a displacement of three-thousandths of an inch measured at the property line. The use of steam or broad hammers shall not be permitted in this district. h. Glare and heat. Glare, such as welding arcs and open furnaces, shall be shielded so that it shall not be visible from the property line. No heat from furnaces or processing equipment shall be sensed at the property line to the extent of raising the temperature of air or materials more than five degrees Fahrenheit. i. Hazardous materials. Operations involving the storage or use of hazardous materials in reportable quantities, as classified by the Environmental Protection Agency (EPA), shall obtain any necessary permits from the Fire Department and make improvements to the building and grounds required by the Uniform Fire Code.
Ask a question about Lee's Summit law
Corpus searches the Lee's Summit sections it holds and shows the ones that match, with their citations. Free, no sign-in.
