§ 5.640 — Development standards
Code of Ordinances of the City of Lee's Summit, Missouri (Codified through Ordinance No. 10423, enacted July 14, 2026 (Supp. No. 56)) · Lee's Summit Unified Development Ordinance § 5.640
Corpus is an independent public-information project, not the official City of Lee's Summit website. Stable reference: corpuslaw.us/code/2006ab81-6c44-4268-8463-c053eac545ea
Sec. 5.640. - Development standards.
A. Sensitive lands and natural resources. The provisions of the stream preservation standards in the City's Design and Construction Manual shall be applicable to development in the ADP. B. Pedestrian and bicycle connectivity and mobility. 1. Purpose. The purpose of this section is to: a. Support the creation of a highly connected transportation system within Lee's Summit in order to provide choices for drivers, bicyclists, and pedestrians; [image omitted; see the official code] Sidewalks on Both Sides of Street b. Increase effectiveness of local service delivery; promote walking and bicycling; connect "development communities" to each other and to local destinations such as employment centers, parks, multi-family units and shopping centers; c. Reduce vehicle miles traveled; improve air quality and reduce emergency response times; d. Mitigate the traffic impacts of new development, and free up arterial capacity for long-distance travel needs; and e. Avoid the creation of large, isolated tracts without routes for traffic, pedestrian and bicycle connections. 2. Sidewalks required. Sidewalks shall be installed on both sides of all streets pursuant to the standards of City's Design and Construction Manual. The Director may allow the use of alternative paving materials if a community improvement district or other long-term oversight board and funding mechanism is established to provide for ongoing maintenance. 3. On-site pedestrian connections. a. Development within the ADP shall provide a network of on-site pedestrian walkways with a minimum width of five feet to and between the following areas: [image omitted; see the official code] On-Site Pedestrian Connections (1) Entrances to each building on the site, including pad site buildings; (2) Public sidewalks, walkways, or trails on adjacent properties that extend to the boundaries shared with the subject development; (3) Public sidewalks along the perimeter streets adjacent to the development; (4) Adjacent land uses and developments; (5) Adjacent public park, greenway, or other public or civic use; and (6) Adjacent public transit station areas, transit stops, park and ride facilities, or other transit facilities. b. On-site pedestrian connections shall be constructed of materials distinguishable from the driving surface such as: [image omitted; see the official code] Decorative Materials for Pedestrian Crossings (1) Changing paving color; (2) Painted crosswalks; or (3) Stamped concrete. Additional identification methods may be used provided an improvement district or other funding mechanism is provided for long-term maintenance. c. Pedestrian circulation routes along storefronts shall be emphasized with special design features that establish them as areas where pedestrians are physically separated from the flow of vehicular traffic and/or are protected from the elements. Techniques shall include one or more of the following: (1) Arcades, porticos, or other shade structures; (2) Pedestrian light features; (3) Bollards; (4) Seat walls or benches; (5) Drinking water fountains; and (6) Landscape planters. d. The placement of street furniture and other decorative or functional items on the sidewalk shall not narrow the sidewalk at any point to less than four feet wide. 4. Trail linkages. a. Trail linkages shall be incorporated into the design of all developments where practical. Trail linkages shall be located and designed to provide public access, connecting residential units and businesses to open space and the City's existing trail system where practical, and to promote pedestrian and bicycle movement between residential areas and employment/business areas. [image omitted; see the official code] Residential Trail Connection b. All development shall be required to demonstrate that the design of the proposed development includes trail linkages pursuant to Lee's Summit Greenway Master Plan, Metro Green, or other applicable plan. c. Trails shall be constructed at the time of development in accordance with adopted City standards and specifications. C. Screening. The following screening standards shall apply in the ADP in addition to the requirements of UDO Article 8, Division III, Landscaping, Buffers, and Tree Protection. 1. Multi-family, mixed-use, and commercial screening. For all developments the following mechanical equipment screening standard shall apply to the maximum extent practicable. [image omitted; see the official code] Parapet Wall Screening Roof Mounted Equipment a. Roof-mounted mechanical equipment. Roof-mounted mechanical equipment shall be screened by a parapet wall or similar feature that is an integral part of the building's architectural design. The parapet wall or similar feature shall be of a height equal to or greater than the height of the mechanical equipment being screened. b. Wall-mounted mechanical equipment. Wall-mounted mechanical equipment, except air conditioning equipment (e.g., window AC units), that protrudes more than six inches from the outer building wall shall be screened from view by structural features that are compatible with the architecture and color of the subject building. Wall-mounted mechanical equipment that protrudes six inches or less from the outer building wall shall be designed to blend with the color and architectural design of the subject building. c. Ground-mounted mechanical equipment. Ground-mounted mechanical equipment shall be screened from view by landscaping or by a decorative wall that is compatible with the architecture and landscaping of the development site. The wall shall be of a height equal to or greater than the height of the mechanical equipment being screened. d. Utilities. (1) Utility poles and supports shall be painted or be of materials neutral in color. Wooden poles shall be prohibited. (2) All transformers and other facilities and equipment, including telecommunications equipment, shall either be screened through the use of architectural materials compatible with the architectural materials present on the site or, alternatively, through landscape screening. (3) Such screening shall be adequate to completely screen such facilities from all rights-of-way. 2. Screening of service, loading, and storage areas. a. Applicability. These screening requirements are applicable to all service, loading, and storage areas. Owners are encouraged to locate the types of features listed in this subsection where they are not visible from off-site or from public areas of a site, so that screening is unnecessary. b. Placement. (1) All service areas shall be placed at the rear, on the side of, or inside buildings. (2) No service area shall be visible from a public right-of-way or from adjacent residential areas. (3) Service areas and access drives shall be located so they do not interfere with the normal activities of building occupants or visitors on driveways, walkways, in parking areas or at entries. c. Outside storage areas and loading docks. (1) All storage areas, service areas, and loading docks not screened by an intervening building shall be screened from view from any public street right-of-way. In addition, storage and loading areas must be screened from view from any adjoining property when that property requires a buffer as identified in UDO Table 8.890, Buffer/Screen Impact. [image omitted; see the official code] Loading Area Placement and Screening (2) An opaque screen consisting of one or a combination of the following shall be used: (a) Freestanding walls, wing walls, or fences; (b) Earthen berms in conjunction with trees and other landscaping; or (c) Landscaping, that must be opaque and eight feet in height within 18 months of planting. (3) Screening shall be a minimum height of eight feet to screen truck berths, loading docks, areas designated for permanent parking or storage of heavy vehicles and equipment or materials. (4) Screening shall be long enough to screen the maximum size trailer that can be accommodated on site. Sites that can accommodate a full size tractor-trailer shall provide a 48-foot length wing wall, where wing walls are used. d. Shopping cart storage. All shopping carts shall be stored inside the building they serve. Shopping cart corrals shall be prohibited. e. Refuse facility screening. All refuse facilities, including new refuse facilities placed on an existing development, shall be large enough to accommodate a trash dumpster and shall be completely screened from view of public streets and adjoining nonindustrial used properties by: [image omitted; see the official code] Refuse Facility Screening (1) Meeting the requirements of the other sections of this section; or (2) Screening on three sides by a minimum six-foot masonry wall surrounded by evergreen landscaping. An opening shall be situated so that the container is not visible from adjacent properties or public streets and the opening shall be a metal clad opaque gate or an alternate approved metal framed gate with black high density mesh screen. Chain-link gates are not permitted. Gates must have tie backs to secure in the open position. f. Design of screening. All screening shall be complementary to the building served in landscaping approach and through the use of similar colors and material palette. D. Multi-family residential development standards. 1. Purpose. The purpose of the multi-family residential development standards is to enhance the quality and character of the built environment in the City. More specifically, the purposes of this section are to: a. Encourage high quality development as a strategy for investing in the ADP; b. Emphasize the unique character anticipated for the ADP; c. Maintain and enhance the quality of life for the City's citizens; d. Shape the City's appearance, aesthetic quality, and spatial form; e. Protect and enhance property values; f. Provide property owners, developers, architects, builders, business owners, and others with a clear and equitable set of parameters for developing land within the ADP; g. Promote the sustainability of both the structure and the overall community; and h. Promote the establishment of a gateway into the historic downtown. 2. Design standards. Design standards in this subsection apply to all new multi-family development. a. Minimum building separation (for individual free standing buildings). Multi-family structures shall be separated pursuant to the standards of the Building Code. [image omitted; see the official code] Courtyard Orientation [image omitted; see the official code] Perimeter Street Orientation b. Building orientation. (1) Individual buildings within a multi-family development shall be oriented to: (a) Common open space, such as interior courtyards or on-site natural areas or features; (b) Perimeter streets; (c) Other residential buildings; or (d) Through-access drives. (2) To the maximum extent practicable, individual buildings shall be oriented or arranged in a manner to enclose common open spaces such as gardens, courtyards, recreation or play areas, that shall contain a minimum of three of these features: (a) Seasonal planting areas, (b) Trees, (c) Pedestrian-scaled lighting, (d) Gazebos or other decorative shelters, (e) Seating, (f) Play structures for children, or (g) Natural features or areas, unless the City determines that for preservation reasons the buildings should avoid the feature or area. c. Entrance orientation. (1) Primary entrances and façades shall not be oriented towards parking lots, garages, or carports. (2) All individual multi-family buildings shall comply with at least two of the following requirements: (a) At least one main building entry faces an adjacent public street; (b) A building entrance faces a courtyard or common open space that has a direct and visible connection to an adjacent public street; (c) A building entry is connected to a public sidewalk by a system of interior walkways; or (d) The pedestrian entries to the site from the public right-of-way are emphasized with enhanced landscaping, special paving, gateways, arbors, or similar features. (3) All ground-floor units with frontage along the primary street shall have an entrance that faces the street. Individual multi-family buildings located with multiple street frontages shall provide entrances to the building along each local street frontage. [image omitted; see the official code] Ground-Floor Unit Entrances (a) Exterior entrances from a public sidewalk or common open space are permitted for dwelling units on the ground floor. (b) Exterior entrances shall be raised from the finished ground-floor level of the sidewalk a minimum of two feet. (4) Dwelling units above the ground floor shall have interior unit entrances including fire stair towers. d. Private common space. Individual multi-family building developments shall provide private common open space for recreation, including uses such as swimming pools, sport courts, playgrounds with equipment, and/or community gardening. Required landscaping is excluded from open space calculations. [image omitted; see the official code] Four-Sided Design 3. Building design. a. Four-sided design. All sides of a multi-family building shall display a similar level of quality and architectural detailing as on the front elevation. b. Building mass and articulation. (1) The elevations of all multi-family buildings shall be articulated through the incorporation of at least three or more of the following: [image omitted; see the official code] Multi-Family Building Articulation (a) Balconies; (b) Bay or box windows; (c) Porches or covered entries; (d) Dormers or other variations in the roof plane; (e) Accent materials such as brick, stone, or stucco with banding highlights; (f) Shutters; (g) Variation in window sizes and shapes; or (h) Vertical elements that demarcate building modules. (2) Multi-family buildings shall provide concentrated unit access points. Access balconies and corridors running the length of the exterior of a building are prohibited. c. Vertical articulation. (1) For all structures three stories or more in height, the base (first 20 feet) of a building shall be distinguished from the remainder of the building by providing a minimum of three of the design elements listed above in subsection b.(1). (2) Multi-family buildings shall be designed to incorporate visually heavier and more massive elements at the building base, and lighter elements above the base. Upper stories shall not appear heavier or demonstrate greater mass than the lower stories of the building. d. Building length. The maximum length of any multifamily building shall be 180 feet without offsets to break up the building length. e. Transparency. At least 20 percent of all walls facing a public street shall contain windows or doorways. f. Design of multiple buildings. (1) Developments with multiple buildings shall incorporate a variety of distinct building designs according to the scale of the development. (2) Distinct building designs shall include one or more of the following: (a) A variation in length of 30 percent or more; (b) A variation in the footprint of the building of 30 percent or more; (c) A distinct variation in color and use of materials; or (d) A distinct variation in building height and roof form. g. Materials. All material shall be durable and long-lasting. The following materials are acceptable for multi-family residential construction: (1) Brick, concrete stucco, stone, stone facing, wood, glass in combination with metal, or similar, durable architectural materials as approved by the Planning Commission. (2) Vinyl siding is prohibited and EIFS may only be utilized in a limited portion for detailed architectural elements above the second story. 4. Parking location and layout. [image omitted; see the official code] Multi-Family Parking Located Behind Primary Structure a. Location and layout. (1) To the maximum extent feasible, garage entries, carports, parking areas, and parking structures shall be internalized in building groupings or oriented away from street frontage. (2) Parking areas and freestanding parking structures (detached garages or carports) shall not occupy more than 30 percent of each perimeter public street frontage of a multi-family development. (3) To the maximum extent practicable, freestanding parking structures that are visible from perimeter public streets shall be sited so that the narrow end of the parking structure is perpendicular to the perimeter street. b. Carports and detached garages. (1) Detached garages and carports shall incorporate compatible materials, scale, colors, architectural details, and roof slopes similar to those of the primary multi-family buildings. (2) Rear walls of detached garages over 40 feet in length that back onto the perimeter street shall be articulated or punctuated through the use of window openings or other similar techniques. E. Mixed-use and commercial design standards. 1. Applicability. The design standards in this section apply to all mixed-use and commercial (nonresidential) structures. 2. Site layout and building organization. a. Private common spaces. [image omitted; see the official code] Private Common Space (1) Required private common spaces. Mixed-use, commercial, and office development shall incorporate at least one on-site indoor or outdoor common space per building. Common space shall be visible and accessible and shall be located, where possible, along street frontages. Common spaces shall be connected, to the maximum extent practicable, to pedestrian areas, sidewalks, trails, or public open space in order to create functional pedestrian connectors. (2) Features and amenities. The following features may be used to satisfy the private common space standard: (a) Patio or plaza with seating and landscaping; (b) Landscaped mini-parks or square; (c) Rooftop or community garden; or (d) Similar features as approved by the Director. (3) Design. Private common spaces shall be constructed of materials that are of a comparable quality and be of a compatible design as the building they are attached to or the public space in which they are placed. b. Building orientation. [image omitted; see the official code] Buildings Arranged to Create Pedestrian-Friendly Spaces (1) Individual buildings. In cases where the long axis of a building is perpendicular to the primary street, the portion of the structure facing the primary street shall be configured with at least one operable entrance and one or more transparent windows as approved by the Director. (2) Multi-building developments. (a) Buildings shall be organized to promote a compact pattern of development, pedestrian-friendly spaces, streetscapes, areas of naturalized landscaping, and to screen parking areas. (b) Buildings shall be arranged and grouped so that their primary orientation complements one another and adjacent, existing development by: 1) Framing the corner of an adjacent street intersection or entry point to the development; 2) Framing and enclosing a pedestrian and/or vehicle road or access corridor within or adjacent to the development site; 3) Framing and enclosing on at least three sides parking areas, public spaces, or other site amenities; 4) Framing and/or enclosing outdoor dining or gathering spaces for pedestrians between buildings; or 5) Framing one or more areas of natural vegetation. (3) Entrance orientation. (a) To the maximum extent feasible, the principal building entrance shall face: 1) An adjacent public street; 2) An adjacent public plaza; or 3) An adjacent primary public walkway. (b) In cases where the principal entrance does not face the principal street, the entrance shall be connected to the street and adjacent parking areas with a sidewalk(s). c. Outparcel development. [image omitted; see the official code] Site Layout of Outparcel Development (1) To the maximum extent practicable, outparcels and their buildings shall be clustered in order to define street edges, entry points, and intimate spaces for gathering or seating between buildings. The even dispersal of outparcel sites in a widely-spaced pattern along streets is strongly discouraged. (2) Spaces between buildings on outparcels shall be improved to provide small-scale pedestrian amenities such as plazas, seating areas, pedestrian connections, gathering spaces, or well-landscaped parking areas. 3. Streetscape design and character. The following standards apply in lieu of the standard sidewalk requirements: a. Public sidewalks required. In order to create an environment that is supportive of transit and pedestrian mobility, public sidewalks shall be provided along both sides of all streets in the mixed-use districts. Such sidewalks shall be at least ten feet in width and should not be more than 16 feet in width, unless otherwise approved as part of the design review process. The ten-foot minimum requirement shall apply regardless of the available right-of-way. Where required, the sidewalk shall extend onto private property to fulfill the ten-foot minimum requirement, with a sidewalk easement provided. b. Delineation of sidewalk area. Sidewalks shall be organized into two distinct areas: A street tree/furniture area located adjacent to the curb, and a clear area. (1) Street tree/furniture area. The street tree/furniture area shall have a minimum width of six feet (from face-of-curb) and shall be continuous and located adjacent to the curb. The area shall be planted with street trees at an average spacing of 20 to 30 feet on center, based on the mature canopy width of the tree species selected and in accordance with Article 8, Division III. The area also is intended for the placement of street furniture including seating, street lights, waste receptacles, fire hydrants, traffic signs, newspaper vending boxes, bus shelters, bicycle racks, public utility equipment such as electric transformers and water meters, and similar elements designed to city specifications and located in a manner that does not obstruct pedestrian access or motorist visibility, and subject to applicable requirements of this UDO. [image omitted; see the official code] Delineation of Sidewalk Area (2) Clear area. The clear area shall be a minimum width of six feet, shall be hardscaped, and shall be located adjacent to the street tree/furniture area. The clear area shall be unobstructed by any permanent or nonpermanent element for a minimum width of six feet and a minimum height of eight feet. Additional sidewalk width located between the clear area and the building may be used for outdoor dining or seating areas. [image omitted; see the official code] Building Set to Sidewalk Clear Area (3) Supplemental zone. A supplemental zone may be provided at the option of the applicant between the street-facing façade or a side-facing facade and the required clear area, to provide additional areas for outdoor dining, porches, terraces, landscape and water features, and plazas. A supplemental zone, if provided, may be a maximum of 20 feet deep and may extend up to 30 percent of the linear frontage of the development. The supplemental zone shall not provide any parking or vehicle circulation areas. (4) Improvement district. An improvement district or other long-term oversight board and funding mechanism shall be established to provide for the maintenance of required streetscape. c. Building placement. At least 70 percent of the building facade facing a public street shall be brought up to the clear area. d. Sidewalk entries. [image omitted; see the official code] Secondary Entry (1) Spacing. Sidewalk entries shall be provided to all buildings and individual units that front on the sidewalk. (2) Sidewalk entry hierarchy. Entrances into residential buildings in mixed-use areas are encouraged to follow a hierarchy of sizes and functions as follows: (a) Carriage way: A centrally located twelve-foot wide entrance at sidewalk level for visual and direct access to a private courtyard. (b) Secondary entry: A six-foot wide entrance with ornamental entrance gate and defined by a stoop with low cheek walls and planters at the sidewalk. Mailboxes, bike racks, and trash receptacles should be grouped around these secondary entries. (c) Other entries: Home office and retail storefront entries which are either at grade or stooped shall be sized to accommodate specific requirements of the individual space. e. Utilities. Transformers, switchgear, and related utility service equipment shall not be located above-ground in pedestrian access easements. Building service panels are to be located on the inside of all buildings. f. Paving. Paving is intended to highlight or accentuate special areas along the ground plane while at the same time complementing the design of adjacent building and streetscape elements. 4. Mix of uses. A diverse range of commercial, office, residential, and civic uses is desired within the ADP, zoned Planned Mixed Use (PMIX). The appropriate mix of uses will vary by its location, size, and the surrounding development contexts. Generally, the ADP should be followed to create the appropriate mix of uses. [image omitted; see the official code] Active Street-Level Uses and Outdoor Gathering Spaces a. Ground-floor uses. (1) Intent. The incorporation of commercial uses such as retail shops and restaurants at the street level is strongly desired within the mixed-use districts to promote a more active environment for pedestrians and support for residential and office uses located within the same building (on upper floors) or nearby. (2) Standards. (a) Location. Commercial uses shall be concentrated adjacent to transit stops, major public spaces, and in other areas where a high level of pedestrian activity and visibility is desirable. If a limited portion of a structure's ground level will be devoted to commercial space, such space shall be located along those facades adjacent to or most visible from transit corridors, primary street frontages, or major pedestrian walkways. (b) Design and use of commercial space. Ground-floor commercial spaces should not be used for residential units. However, residential unit leasing offices, fitness centers, and related accessory uses are appropriate for commercial ground floor use in a mixed use developments. b. Residential uses. Residential uses, where included, shall be incorporated within a mixed-use development to be visually and/or physically integrated with commercial (nonresidential) uses. This shall be achieved by ensuring that residential uses meet at least one of the following: (1) Residential uses are vertically located above street-level commercial uses; (2) Residential uses are horizontally integrated into site development to provide a transition between the highest intensity uses within the center or development and the adjacent neighborhood; and (3) A pedestrian circulation system (i.e., sidewalks, crosswalks, trails, etc.) is provided that reduces conflict between pedestrian and vehicular movements and increases pedestrian activity between residential and nonresidential uses. 5. Parking standards for mixed-use districts. The purpose of parking area requirements is to ensure that the parking areas themselves are not the dominant feature of the mixed-use development. These requirements severely restrict on-site surface parking (other than incidental parking in association with residential development leasing offices, or head-in or parallel spaces to support retail uses) and encourage physical consistency throughout the development, including the appearance of parking garages. In all mixed-use districts, the following standards apply: a. Allowable parking. On-street parking shall not be designated per individual business or occupancy but may count toward the minimum parking requirements for the entire structure along the adjacent frontage. Parallel parking, head-in parking along streets, and/or minimal surface parking is permitted subject to approval through the site plan or development plan process and approval of a maintenance agreement. b. Bicycle parking design and location. (1) Bicycle parking facilities shall include a rack or storage facility (e.g., locker) that enables bicycles to be secured. Where racks are used, they shall meet the following standards: (a) The bicycle frame and one wheel can be locked to the rack with a high-security, U-shaped shackle lock if both wheels are left on the bicycle; (b) A bicycle six feet long can be securely held with its frame supported so that the bicycle cannot be pushed or fall in a manner that will damage the wheels or components; and (c) The rack must be securely anchored. (2) Bicycle racks and storage facilities shall be accessible without moving another bicycle. (3) Bicycle racks and storage facilities shall be located in convenient, visible, well-lit areas with easy access and near main entrances of all commercial, residential, and institutional buildings. Such locations shall be clearly noted with signage. (4) The racks and storage facilities shall be located so they do not interfere with pedestrian traffic and shall be protected from potential damage by motor vehicles. (5) Bicycle parking shall not be within any required landscape area nor interfere with any pedestrian pathway. c. Parking lot screening. In all mixed-use districts, all surface parking lots adjacent to a public street shall be screened using one of the following methods below: (1) An informal hedge at least three feet in height at maturity consisting of a double row of shrubs planted three feet on-center in a triangular pattern; or (2) Berming of the grade to at least two and one-half feet in height above the finish grade of the parking lot, and with slopes no greater than 2:1. Slopes shall be covered with shrubs spaced a maximum of three feet on center. Trees and flowering plants may be included in the berm plantings where the Director finds that long-term maintenance will be provided. d. Parking structure design. The off-street parking required by mixed-use and non-residential development may be located in a parking structure. Such structure shall be subject to the following standards: (1) Design. (a) Parking structures shall be constructed of materials of similar quality and shall be compatible in appearance with adjacent buildings and shall contain lighting sufficient for security as approved by the City. (b) Ground floor facades of parking structures not occupied by active public uses shall be articulated through the use of three or more of the following architectural features. 1) Windows or window-shaped openings with decorative mesh or similar features as approved by the Director; 2) Masonry columns; 3) Decorative wall insets or projections; 4) Awnings; 5) Changes in color or texture of materials; 6) Approved public art; 7) Integrated landscape planters; or 8) Other similar features approved by the Director. (2) Entry design. Vehicle entries to off-street parking structures shall be integrated into the placement and design of adjacent buildings or oriented away from the primary street frontage. At a minimum, parking structures shall have user vehicles access from a location that minimizes conflicts with pedestrian circulation. (3) Wrapping of parking structure. Where feasible, the ground floor of parking structures in mixed-use or non-residential districts shall be wrapped with active public uses along at least 60 percent of the ground-floor street frontage. Parking structures with ground floors that are not wrapped with active public uses on the sides facing a public street or open to public view shall not: [image omitted; see the official code] Parking Structure (a) Abut street intersections or public/civic use areas, (b) Be adjacent to public squares, or (c) Occupy sites that are the terminus of a street vista. 6. Building design. [image omitted; see the official code] Franchise Design Consistent With Surrounding Structures a. Four-sided design. (1) All sides of a building shall be architecturally finished with equal levels of materials and detailing. Blank walls void of architectural details or other variation are prohibited. (2) Exceptions from the above standard may be granted for those areas of the building envelope that the applicant can demonstrate are not visible from adjacent development and public spaces. (3) Corporate or franchise architecture is discouraged in favor of architecturally compatible designs. The Director may require photographic examples of the more minimized corporate architecture in the designs and completed structure by the same company in other communities. b. Consistent architectural theme. (1) The architectural design within a multi-building development of structures (including freestanding outparcel structures) shall be organized around a consistent architectural theme in terms of the character, materials, texture, color, and scale of buildings. Themed restaurants, retail chains, and other franchise-style structures shall adjust their standard architectural model to be consistent with a development's architectural character. (2) All buildings in a single development, whether developed at a single time or in phases, shall share at least four architectural features in order to create continuity within the overall development. These features include, but are not limited to, the following: (a) Overhangs, (b) Canopies or porticos, (c) Recesses/projections, (d) Arcades, (e) Raised corniced parapets over the entrance, (f) Peaked roof forms, (g) Arches, (h) Outdoor patios, (i) Tower elements (at strategic locations), (j) Display windows, (k) Integral planters that incorporate landscaped areas or seating areas, and (l) Public art/sculptures. c. Building materials and colors. (1) Permitted materials. Building materials shall consist of brick, stone, precast masonry, and stucco. Pre-authorized use of limited amounts of conditional materials may be approved including architectural metal, CMU's and exterior insulated finishing systems (EIFS). (2) Mix of materials. (a) No single building material shall cover more than 80 percent of the front building façade. Windows and doors shall not be counted as additional building materials. (b) Structures 20,000 square feet or less shall require a minimum of two distinct building materials on all facades to provide architectural detail and interest. (c) Structures over 20,000 square feet shall require a minimum of three distinct building materials on all facades to provide architectural detail and interest. (3) Prohibited Materials. The following materials are prohibited as primary cladding or roofing materials: (a) Aluminum siding or cladding, (b) Plastic or vinyl siding, (c) Exposed aggregate, and (d) Wood shingles. (4) Façade colors. (a) Colors of paint, stains, and other finishes or materials shall complement each other. [image omitted; see the official code] Mix of Building Materials (b) Generally, no more than four colors per building are permitted. (c) Fluorescent colors are prohibited. (d) Primary colors are prohibited. (e) The use of stark white is discouraged. (5) Transparency and glazing. (a) At least 25 percent of all walls facing a public street shall contain windows or doorways. (b) Glazing shall be effectively clear, and shall not exceed 40 percent reflectance. Divided-light windows are encouraged. Materials that create noticeable glare or which restrict the ability of the public to view the inside of a structure from the outside are generally prohibited but may be allowed in limited locations in structures intended for financial or other uses with documentable safety concerns. (c) Energy conserving window films and coatings are permissible within these standards. d. Gateways. Buildings located at entrances to a development demarcate a gateway that will create an overall identity, set the tone for the development, and mark arrival or entry. (1) At major entry points of a development with three or more buildings, buildings shall be organized along the street and at the intersection to create a gateway. (2) Architectural features shall be incorporated into the facades of buildings at major entry points to help emphasize arrival or entry points into the development. These features may include, but are not limited to: (a) Eaves, (b) Planters, (c) Mounted signs, (d) Pilasters, (e) Tower elements, (f) Water features, or (g) Arcades. 7. Building massing and form. a. Vertical articulation. Buildings greater than two stories or taller than 30 feet shall be designed to reduce apparent mass by including a clearly identifiable base, body, and top, with horizontal elements separating these components. The component described as the body must constitute a minimum of 50 percent of the total building height. [image omitted; see the official code] Vertical Articulation b. Horizontal articulation. Buildings shall be designed to reduce apparent mass by dividing facades into a series of smaller components. No individual component shall have a length of more than 60 feet. Components shall be distinguished from one another through two or more of the following: (1) Variations in roof form and parapet heights; (2) Pronounced recesses and projections; (3) Distinct changes in texture and color of wall surfaces; (4) Ground level arcades and second floor galleries/balconies; (5) Protected and recessed entries; and (6) Vertical accents or focal points. c. Relationship to surrounding development. New developments that are significantly larger than adjacent existing development in terms of their height and/or mass shall provide a development transition using an appropriate combination of the following techniques: [image omitted; see the official code] Appropriate Transition in Building Height and Mass (1) Wrapping the ground floor with a building element or integrated architectural feature (e.g., pedestrian arcade) that is the same height as the adjacent structure; (2) Graduating building height and mass in the form of building step-backs or other techniques so that new structures have a comparable scale with existing structures; or (3) Orienting porches, balconies, and other outdoor living spaces away from the shared property line to protect the privacy of adjacent residents where applicable. d. Entrances and pedestrian areas. (1) Primary entries and pedestrian frontages shall be clearly visible from the street and accentuated from the overall building façade by: [image omitted; see the official code] [image omitted; see the official code] Entrance Design and Pedestrian Areas (a) Differentiated roof, awning, or portico; (b) Covered walkways or arcades; (c) Projecting or recessed entries from the surrounding building facade; (d) Detailed doors and doorways with transoms, sidelights, trim details, and/or framing; and (e) Windows within doorways equivalent in size to 50 percent of door surface area. (2) Secondary entrances shall have minor architectural detailing that adds visual interest to that portion of the façade. e. Roofs. (1) Roofline articulation. Variations in roof lines shall be used to add interest and reduce the scale of large buildings. Roof features shall complement the character of the overall development. (2) Flat roofs. Flat roofs shall include parapets that adhere to articulation requirements for the main face of the structure. The average height of the parapet shall not exceed 15 percent of the height of the supporting wall, unless rooftop equipment cannot be sufficiently screened. A three-dimensional cornice treatment is encouraged for parapets. Parapets shall look complete from all sides if visible at any distance from the ground. (3) Overhanging eaves. Overhanging eaves shall extend no less than three feet past the supporting walls. (4) Roof pitch. Pitched roofs shall have a pitch consistent with the majority of buildings within 1,000 feet. This requirement excludes roofs for entries and dormers. (5) Architectural elements. Architectural elements that add visual interest to the roof, such as dormers and masonry chimneys, are encouraged. (6) Roof materials. (a) Asphalt shingles, industry-approved synthetic shingles, standing seam metal or tile roofs are allowed. (b) Wood shingles are prohibited. Corrugated metal, tar paper, and brightly-colored asphalt shingles may be permitted by the Director where they will not be visible from a roadway, public park, or residential district or use. f. Awnings, canopies, arcades, and overhangs. Structural awnings are encouraged at the ground level to enhance the articulation of the building and provide shade. (1) The material of awnings and canopies shall complement the building. (2) Awnings shall not be internally illuminated. (3) Canopies shall not exceed 40 linear feet without a break. (4) Awnings shall not extend more than five feet over the sidewalk, unless otherwise approved by the Director, up to a maximum of 10 feet, and are in keeping with the architectural style of the building. (5) Canopies shall respect the placement of street trees and lighting and shall not interfere with them. (6) All large canopies that require structural columns for support shall have a minimum six-foot masonry (or other approved material) finish measured from the finished grade. Materials used on columns and canopies shall be complementary to the building. 8. Compatibility standards. a. Applicability. The compatibility standards in this subsection only apply when nonresidential or mixed-use development is proposed adjacent to lots used by or zoned for detached or attached single-family structures in a residential district outside of the ADP. b. Use limitations. Where these compatibility standards apply, the following uses or features shall be prohibited as principal or accessory uses: (1) Public address/loudspeaker systems; (2) Outdoor storage; and (3) Uses providing delivery services via large tractor trailers (not including package delivery services). c. Off-street parking location. (1) Off-street parking shall be established in one or more of the locations listed below. The locations are listed in priority order; the applicant shall select the highest feasible location from this list, and shall demonstrate why that application was selected over other alternative locations. (a) Adjacent to off-street parking lots serving nonresidential uses on abutting lots; (b) Adjacent to lot lines abutting nonresidential development; (c) Adjacent to lot lines abutting mixed-use development; (d) Behind the building; (e) In front of the building; or (f) Adjacent to lot lines abutting residential uses. (2) In cases where an off-street parking lot serving a nonresidential use is located on an abutting lot, connection between the two parking areas via a cross-accessway with a minimum width of 12 feet and a maximum width of 24 feet is strongly encouraged. A cross-access easement shall be recorded. d. Relationship to surrounding uses. (1) Multi-building developments shall be configured to locate the tallest and largest structures within the core of the site and provide a gradual decrease in building height and mass towards adjacent residential land use. [image omitted; see the official code] Gradual Decrease in Building Height and Mass Towards Adjacent Residential Uses (2) Horizontally integrated mixed-use developments shall locate nonresidential uses away from lots in adjacent residential areas. (3) Medium to high density housing shall be incorporated to the maximum extent feasible both within and around the development to facilitate connections between residential and non-residential uses. e. Façade configuration. (1) Service functions like refuse collection, incidental storage, and similar functions shall be integrated into the architecture of the building unless an alternate location places these functions farther from adjacent residential uses. (2) Windows shall be arranged to avoid direct lines-of-sight into abutting residential uses. (3) Multi-story structures with balconies, patios, or other public gathering spaces more than 24 feet above grade shall orient these features to avoid direct views into lots in low- and medium-density residential districts. f. Landscaping/screening. (1) Screening shall not interfere with public sidewalks, vehicular cross-accessways, or improved pedestrian connections. (2) Any parking designated for trucks, recreational vehicles and other large vehicles shall be placed in a location which is not adjacent to either any street or to any residentially zoned property. g. Operation. (1) Nonresidential uses with outdoor components (e.g., outdoor dining, performance venues) located adjacent to lots in a residential district shall curtail outdoor activities by 10:00 p.m. (2) Loading or unloading activities shall take place only between the hours of 7:00 a.m. and 11:00 p.m. (3) Alternate hours of activities may be approved through the conditional use permit process. 9. Green design. To the maximum extent practicable, new buildings are encouraged to incorporate one or more of the following features: [image omitted; see the official code] Commercial Building With Solar Panels a. Opportunities for the integration of renewable energy features in the design of buildings or sites, such as: Solar, wind, geothermal, biomass, or low-impact hydro sources; b. Energy-efficient materials, including recycled materials that meet the requirements of this Code; c. Materials that are produced from renewable resources; d. A green roof, such as a vegetated roof, or a cool roof; e. Materials and design meeting the U.S. Green Building Council's LEED-NC certification requirements; or f. A greywater recycling system.
Ask a question about Lee's Summit law
Corpus searches the Lee's Summit sections it holds and shows the ones that match, with their citations. Free, no sign-in.
