Sec. 7-1308.2. - Strike plates.

Exterior door strike plates shall be a minimum of eighteen (18) gauge metal with four (4) offset screw holes. Strike plates shall be attached to wood with not less than three (3) inch wood screws, which shall have a minimum of one inch penetration into the nearest stud. Note: For side lighted units, refer to Section 7-1308.5.

(Ord. No. 8584, § 1, 3-19-2019)