§ 400.105 — "R-4" Apartment Building District
Code of Ordinances, City of O'Fallon, Missouri (Code 2026-10-22) · O'Fallon City Code § 400.105
Corpus is an independent public-information project, not the official City of O'Fallon website. Stable reference: corpuslaw.us/code/af9c750c-242c-47f6-8d44-3df2b8bf11b1
Section 400.105: "R-4" Apartment Building District.
A. Purpose. This district is composed of those areas of the City whose principle use is or ought to be multiple-family dwellings at a high density. The regulations of this district are designed to permit a higher density of population and a higher intensity of land use in those areas which are served by a central water supply system and a central sanitary sewerage system, and which abut or are adjacent to such other uses, buildings, structures, or amenities which support complement or serve such a density and intensity. In addition to the dwellings permitted in this zoning district, there are permitted certain residential and public uses which have been strictly regulated to make them compatible with the principle use of this district. B. Permitted Uses. The listing of permitted uses is set out in Appendix "A" of this Title.[1] C. Conditional Uses. The listing of conditional uses is set out in Appendix "A" of this Title. D. Regulations And Performance Standards. The following regulations shall apply in all "R-4" Apartment Building Districts: 1. Site Area. Any site zoned "R-4" Apartment Building District shall have a minimum area of not less than one (1) acre unless the project abuts an existing multi-family zone. 2. Minimum Lot Area. a. Single-Family Dwelling. Seven thousand five hundred (7,500) square feet. b. Two-Family Dwelling. (1) Seven thousand five hundred (7,500) square feet for a two-family dwelling located on a single platted lot of record that does not provide for the sale of the individual dwelling units. (2) Five thousand (5,000) square feet for a two-family dwelling located on two (2) separately platted lots of record and the interior side lot line (party lot line) runs coincident with the common firewall separating the side-by-side units. NOTE: Up to five percent (5%) of the total number of dwelling units may consist of single-family detached units on separately platted minimum five thousand (5,000) square foot lots of record. (3) Seven thousand five hundred (7,500) square feet for a two-family dwelling located on a single platted lot of record and: (a) The individual dwelling units share a common firewall separating the side-by-side units; (b) The individual dwelling units are sold as condominium or town house/villa units; and (c) The remainder of the lot is set aside as common elements or common ground. NOTE: Up to five percent (5%) of the total number of dwelling units may consist of single-family detached units on separately platted lots of record with the individual dwelling unit sold as a condominium or town house/villa unit with the remainder of the lot set aside as common elements or common ground. Said lots shall have a minimum lot area of five thousand (5,000) square feet. c. For non-residential permitted and conditionally permitted uses in this zoning district per the allowances of Appendix A,[2] the minimum lot area shall be adequate, as determined by the Planning and Zoning Commission, to provide the required yard requirements of this zoning district and the required off-street parking per Article XII of the Zoning Code. 3. Minimum Lot Width. (measured at the building line). a. Single-Family Dwelling. Seventy (70) feet. b. Two-Family Dwelling. Per the requirements of Section 400.095(D) of the Zoning Code. c. Multi-Family Dwelling. Seventy (70) feet. d. For non-residential permitted and conditionally permitted uses in this zoning district per the allowances of Appendix A, the minimum lot width shall be adequate, as determined by the Planning and Zoning Commission, to provide the required yard requirements of this zoning district and the required off-street parking per Article XII of the Zoning Code. 4. Maximum Lot Coverage. a. Single-Family Dwelling. Thirty-five percent (35%). b. Two-Family Dwelling. Per the requirements of Section 400.095(D) of the Zoning Code. c. Multi-Family Dwelling. Forty percent (40%). 5. Yard Requirements. a. Single-Family Dwelling. (1) Front Yard. Not less than twenty-five (25) feet. (2) Side Yards. Not less than six (6) feet, except in the case of a corner lot where the side yard on the road or street side shall not be less than twenty-five (25) feet. (3) Rear Yard. Not less than fifteen (15) feet. b. Two-Family Dwelling. Per the requirements of Section 400.095(D) of the Zoning Code. c. Multi-Family Dwelling. (1) Front Yard. Not less than thirty-five (35) feet. (2) Side Yards. Not less than fifteen (15) feet, except in the case of a corner lot where the side yard on the road or street side shall not be less than thirty (30) feet. (3) Rear Yard. Not less than thirty (30) feet. (4) Accessory structures shall meet the same yard requirements. (5) The above requirements shall apply to every lot, building or structure. 6. Height Requirements. Except as is otherwise provided in Article VI, no building shall exceed four (4) stories above finished grade or fifty (50) feet, whichever is the lesser. 7. Distance Between Grouped Buildings [Multi-Family Dwellings Of Less Than Two And One-Half (2 1/2) Stories In Height]. In addition to the yard requirements for multi-family dwellings listed in Section 400.105(D)(5) of this Section, the minimum distance between grouped buildings requirements contained within Section 400.100(D)(7) shall apply. 8. Distance Between Grouped Buildings [Multi-Family Dwellings Of More Than Two And One-Half (2 1/2) Stories In Height]. In addition to the yard requirements for multi-family dwellings listed in Section 400.105(D)(5) of this Section, the following minimum distances shall be required between buildings containing multi-family dwellings: a. Front to front: Sixty (60) feet. b. Front to back: Sixty (60) feet. c. Back to back: Sixty (60) feet. d. Side to side: Thirty (30) feet. e. Front to side: Forty-five (45) feet. f. Back to side: Forty-five (45) feet. g. Corner to corner: Twenty (20) feet. 9. Off-Street Parking. As required in Article XII. The construction of a covered parking space for each dwelling unit shall be optional. The roof shape and materials of the covered parking structure(s) shall match the roof shape and materials of the multi-family residential structure(s). 10. Site Plan Review. By Planning and Zoning Commission prior to issuance of a building permit, as required in Article XIV. 11. Utilities. Any area zoned "R-4" Apartment Building District shall be served by approved public water and sewer facilities. 12. Landscaping And Screening Requirements. See Chapter 402 of this Code. 13. Design. All multi-family residential structures are to be constructed with brick veneer, or comparable material, on the front portion of said dwelling units and on any side or back that abuts single-family "R-1" dwelling units. 14. Density — Multi-Family Dwelling. The total number of units per acre shall not exceed fourteen (14).
[ Ord. No. 7042 , 8-24-2023 ]
Ask a question about O'Fallon law
Corpus searches the O'Fallon sections it holds and shows the ones that match, with their citations. Free, no sign-in.
