Section 400.175: Design Standards For A Planned Development.
A. Size Requirements. There shall be no minimum or maximum size requirement for a site to be developed as a Planned Development. B. Permitted Modifications To The Zoning District Regulations. Upon approval by the City Council, a Planned Development may depart from strict conformance to certain underlying zoning district regulations to which the Planned Development designation has been attached. The departure from strict conformance to these underlying zoning district regulations shall only be permitted if deemed necessary for the proper design of the Planned Development. Proposed modifications to the underlying zoning district regulations are limited to one (1) or more of the following: 1. Reduction of the minimum lot area requirements. 2. Reduction of the minimum lot width requirements. 3. Reduction of the minimum lot depth requirements. 4. Reduction of the front yard setback requirements. 5. Reduction of the side yard setback requirements. 6. Reduction of the rear yard setback requirements. 7. Reduction of the distance between grouped buildings requirements. 8. Increase in the maximum lot coverage requirements. 9. Increase in the maximum height requirements. 10. Modification to the landscaping requirements. 11. Modification to the off-street parking and loading requirements. C. Permitted Modifications To The Subdivision And Land Development Code Regulations. Upon approval by the City Council, a Planned Development may depart from strict conformance to certain regulations of the Subdivision and Land Development Code. The departure from strict conformance to these Subdivision and Land Development Code regulations shall only be permitted if deemed necessary for the proper design of the Planned Development. Proposed modifications to the Subdivision and Land Development Code are limited to one (1) or more of the following: 1. Reduction of the minimum right-of-way requirements for minor residential and cul-de-sac streets. 2. Reduction of the minimum centerline radii for minor residential and cul-de-sac streets. 3. Reduction of the minimum corner radii at the back of curb for minor residential and cul-de-sac streets. 4. Reduction of the minimum block length. 5. Increase in the maximum block length. 6. Increase in the maximum length of cul-de-sacs. 7. Modification to the requirements for private alleys. 8. Modification to the requirements for sidewalks. 9. Modification to the requirements for street tree placement. D. Regulations Which May Not Be Modified. A Planned Development must meet the use and density limitations of the underlying zoning district in which the development is to be located. All requirements of the underlying zoning district and the Subdivision and Land Development Code remain applicable except as specifically modified pursuant to the allowance of this Article as approved by the City Council. Under no circumstances shall the applicable flood hazard prevention requirements, stormwater detention requirements, grading requirements, soil erosion and sediment control requirements, central utility requirements, tree preservation requirements, screening of outdoor equipment requirements, or performance standards (e.g., air and water pollution, noise, odor, fire hazard, etc.) be modified in conjunction with the approval of a Planned Development. In addition, all other City, County, State, and Federal regulations and development requirements shall apply to the Planned Development. E. Residential Density. Under no circumstances shall the residential density of a Planned Development exceed that which would normally be permitted in the underlying residential zoning district to which the Planned Development designation has been attached. 1. Calculation Of Density. The computation of residential density shall be based on the dwelling units per net acreage of the residentially zoned portion of the site. Net acreage is determined by subtracting the area devoted to public street rights-of-way, private alleys and dry detention basins from the gross acreage of the residentially zoned portion of the site. To compute residential density, the net acreage of the residentially zoned portion of the site shall be divided by the smallest minimum lot size allowed in the underlying residential zoning district to which the Planned Development designation has been attached. In situations where a Planned Development designation is attached to two (2) or more underlying residential zoning districts, the residential density shall be calculated separately for each of the underlying residential zoning district to which the Planned Development designation has been attached. F. Permanent Protection Of Environmentally Sensitive Areas. All environmental protection planned developments shall, to the satisfaction of the City Council, be designed in accordance with the following requirements: 1. No modification, alteration or construction of any type may occur in flood hazard areas. This includes all floodways, all floodway fringe areas, areas of 500-year flood, areas of 100-year flood with average depths of less than one (1) foot or with drainage areas less than one (1) square mile, and areas protected by levees from 100-year flood. 2. No modification, alteration or construction of any type may occur in areas containing wetlands as determined by the U.S. Army Corp of Engineers. 3. No modification, alteration or construction of any type may occur in ditches, creeks, streams, or other watercourses and natural drainage ways vital to the natural performance of the watershed as determined by the City's Stormwater Engineer. 4. No modification, alteration or construction of any type may occur in areas where slopes are in excess of forty percent (40%). To the maximum extent feasible, cutting, filling and benching or terracing of areas with slopes ranging from fifteen percent (15%) to forty percent (40%) for the purpose of creating additional building area or larger building sites shall be prohibited. 5. No modification, alteration or construction of any type may occur in areas containing soils classified as A-6 to A-8 on the American Association of State Highway and Transportation Officials (A.A.S.H.T.O.) Soil Classification System. These soils are classified as either easily erodible, clayey or highly organic as defined by the Soil Survey of St. Charles County, Missouri, published by the United States Department of Agriculture (U.S.D.A.) Soil Conservation Service. The water table may not be higher than one (1) foot below the lowest floor in any proposed structure. 6. No modification, alteration or construction of any type may occur in areas determined to be vital aquifer recharge or discharge areas as determined by the Missouri Department of Natural Resources, the U.S. Army Corp of Engineers or the City's Stormwater Engineer. 7. No modification, alteration or construction of any type may occur in areas determined to be vital for the protection of wildlife as determined by the Missouri Department of Conservation. 8. No modification, alteration or construction of any type may occur in areas determined to be of archaeological or historical significance as determined by the Missouri Department of Natural Resources State Historic Preservation Office. 9. Existing trees preserved within the areas within the environmental protection planned development subject to the above-listed requirements may be counted towards meeting the tree preservation requirements of Chapter 402, Trees and Landscaping, of this Code. 10. All areas within the environmental protection planned development subject to the above-listed requirements shall be identified on a separate environmentally sensitive area protection plan included as part of both the area plan and final plan applications. The environmentally sensitive area protection plan may be combined with the tree preservation plan required per Chapter 402 of this Code. 11. All areas within the environmental protection planned development subject to the above-listed requirements shall be protected through the establishment of a permanent conservation easement held by the landowner(s), a homeowners' association or a land trust. G. Common Ground Requirements. At least twenty percent (20%) of the gross land area of an environmental protection planned development or a residential redevelopment planned development, or an area of a size equivalent to one (1) acre for each one hundred (100) persons of expected population of the development, whichever is greater, shall be set aside as common ground. The expected population shall be determined by multiplying the total number of dwelling units by three (3) persons (the City's average household size per the 2020 Census). Common ground shall be designed in accordance with the following requirements: 1. Private alleys and dry detention basins may not be counted towards meeting the common ground requirement. 2. The natural areas protected through the establishment of the required permanent conservation easement in an environmental protection planned development may be included in meeting all or part of the common ground requirement. The extent that these natural areas may be counted towards meeting the common ground requirement will be dependent upon the suitability of the natural areas for use by residents as determined by the City Council. 3. To the satisfaction of the City Council, throughout environmental protection planned developments and residential redevelopment planned developments, common ground shall be equitably distributed in relation to the dwelling units that such common ground is intended to serve and shall be connected via a series of sidewalks, paths or multi-purpose trails. 4. Lakes that serve the dual purpose of stormwater retention may be counted towards meeting one-fourth (1/4) of the common ground requirement. 5. Areas within common ground that contain recreational amenities shall be counted towards meeting the common ground requirement. 6. The use, operation and maintenance of common ground within an environmental protection planned development or a residential redevelopment planned development shall be guaranteed by the establishment of trust indentures providing for the establishment of a homeowners' association. Said trust indentures shall be approved by the City staff prior to recording the trust indentures simultaneously with the recording of the record plat. H. Perimeter Buffering Requirements. Regardless of political boundaries, when a residential Planned Development is proposed adjacent to an existing residential development or residential zoning district, there shall be a minimum twenty (20) foot wide permanent buffer area. Regardless of political boundaries, when a residential Planned Development is proposed adjacent to an existing commercial, office, high tech or industrial land use or non-residential zoning district, there shall be a minimum thirty (30) foot wide permanent buffer area. Regardless of political boundaries, when a non-residential Planned Development is proposed adjacent to an existing residential development or residential zoning district, there shall be a minimum thirty (30) foot wide permanent buffer area. These buffer areas shall be: 1) uniform in setback at all points on the perimeter of the Planned Development; 2) kept in a natural state (if sufficient tree mass exists) or landscaped and/or otherwise provided with screening (i.e., sightproof fencing and/or landscaped earthen berms) to the satisfaction of the City Council; and 3) be kept free of buildings, structures and impervious surfaces. These buffer areas may be designated as common ground or placed within permanent easements on the individual lots. If these buffer areas are placed within permanent easements on the individual lots, the required building setbacks shall be measured from the inside line of the permanent easements. I. Perimeter Minimum Lot Size Requirements. The perimeter lots within a proposed residential Planned Development adjacent to any existing, proposed, approved or under construction residential subdivision (regardless of political boundaries) must meet or exceed the size and dimensional configuration of the adjacent residential lots in the neighboring subdivision. The only exception to this requirement is when the perimeter lots of a proposed residential Planned Development are adjacent to existing, proposed, approved or under construction residential lots in a neighboring subdivision (regardless of political boundaries) that are two (2) acres or greater in size. When the perimeter lots of a proposed residential Planned Development are adjacent to existing, proposed, approved or under construction residential lots in a neighboring subdivision (regardless of political boundaries) that are two (2) acres or greater in size, the perimeter lots of a proposed residential Planned Development adjacent to these lots shall be a minimum of two (2) acres in size.
[ Ord. No. 7042 , 8-24-2023 ]
Ask a question about O'Fallon law
Corpus searches the O'Fallon sections it holds and shows the ones that match, with their citations. Free, no sign-in.