§ 400.960 — Small Wind Energy Systems
Code of Ordinances, City of O'Fallon, Missouri (Code 2026-10-22) · O'Fallon City Code § 400.960
Corpus is an independent public-information project, not the official City of O'Fallon website. Stable reference: corpuslaw.us/code/b4943684-aa8f-47da-bbb2-45ea12ec4364
Section 400.960: Small Wind Energy Systems.
A. General Requirements. The provisions of this Section apply to the construction and/or installation of all small wind energy systems: 1. Location. All wind energy systems shall be located in the rear yard on a lot. 2. Electrical Wires. All electrical wires associated with a wind energy system must be buried below the surface of the ground, except for those wires necessary to connect the wind generator to the tower wiring, the tower wiring to the disconnect junction box, and the grounding wires, in accordance to the current Electrical Code adopted by the City. 3. Controls And Brakes. All systems shall contain an internal governor or braking device which engages at a manufacturer-specified wind speed intended to ensure the safe operation of the system in all wind conditions. 4. Lighting. Wind energy conversion systems shall not be illuminated by artificial means, except where the illumination is specifically required by the Federal Aviation Administration or other Federal, State, or local regulations. 5. Colors. Wind turbines shall be painted a non-reflective, non-obtrusive color such as the manufacturer's default color option or a color that conforms to the environment and architecture of the area in which it is located. 6. Noise. The noise emitted from any wind turbine shall comply with Section 400.555 and Section 215.237 of this Code of Ordinances. 7. Signage. Signs shall be limited to the manufacturer's or installer's identification, and required warning signs (e.g., electrical hazard or high voltage) placed on the wind turbine tower(s), electrical equipment, and the wind turbine. Commercial advertising is strictly prohibited. B. Building-Mounted Wind Energy Systems. 1. Allowed Structures. Building-mounted wind energy systems shall only be allowed on non-residential structures. 2. Height Requirements. No building-mounted wind energy system shall exceed the height requirement for zoning district in which it is located. 3. Written Analysis. A written certification from a Missouri-licensed structural engineer regarding the weight of the total installation per square foot and certifying that the structure has the structural integrity to carry the weight and wind loads of the wind energy conversion system and have minimal vibration impacts on the structure. C. Decorative Wind Energy Systems. 1. Requirements. Decorative wind energy systems shall be permitted in any yard without a building permit. D. Small Wind Energy System Towers. 1. Monopole Tower. Monopole wind energy systems shall be conditionally permitted in commercial and industrial zoning districts. Monopole structures shall be prohibited in all residential zoning districts and the Mixed-Use Traditional Development District (MUTDD), unless located in a property used solely for a non-residential use (such as religious institutions, schools, fire stations, libraries, utility substations, cemeteries, parks, golf courses, etc.). 2. Guyed And Lattice Towers. Guyed and lattice towers shall only be permitted in industrial zoning districts. 3. Number Of Towers Per Lot. No more than two (2) ground-mounted wind energy systems that supplement energy consumption may be installed on any lot. 4. Rotor Distance. The minimum distance between the ground and any part of the rotor blade system shall be fifteen (15) feet. 5. Height And Setback Requirements. The setbacks listed below shall apply to all adjacent property and utility lines. Districts | Max. Height(feet) | Min. Setback | Tower Design Permitted Non-residential uses in "R-1," "R-1A," "R-2," "R-3," "R-4," "R-5," "TGB" and "MUTDD" | 75 | 1 foot of setback for each foot of height of a freestanding tower in motion plus 10 feet when adjacent to residential uses or zoned property | Monopole "C-O," "C-1," "C-2," "C-3," "HTCD," "AG" and "P-R" | 125 | Monopole "I-1" and "I-2" | 150 | Monopole, guyed wire, lattice
[ Ord. No. 7042 , 8-24-2023 ]
Ask a question about O'Fallon law
Corpus searches the O'Fallon sections it holds and shows the ones that match, with their citations. Free, no sign-in.