For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 415.190 — Specific Standards

Code of Ordinances, City of O'Fallon, Missouri (Code 2026-10-22) · O'Fallon City Code § 415.190

Corpus is an independent public-information project, not the official City of O'Fallon website. Stable reference: corpuslaw.us/code/7e0c9797-9a33-4b12-9747-2c6ec0c73aa6

Section 415.190: Specific Standards.

A. In all areas of special flood hazards where base flood elevation data has been provided as set forth in Article III, Section 415.070 or Article IV, Section 415.140(A)(8) (Zones A and AE) or areas that have had fill placed to remove it from the special flood hazard area, the following provisions are required: 1. Residential Construction. New construction or substantial improvement of any residential structure shall have the lowest floor, including basement, elevated to two (2) feet or more above the base flood elevation. 2. Non-Residential Construction. New construction or substantial improvement of any commercial, industrial or other non-residential structure shall either have the lowest floor, including basement, elevated to two (2) feet or more above the base flood elevation or, together with attendant utility and sanitary facilities, be flood proofed so that below such a level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall certify that the standards of this Subsection are satisfied. Such certification shall be provided to the Floodplain Administrator as set forth in Section 415.140(A)(7). 3. Requirements For All New Construction And Substantial Improvements. Fully enclosed areas below the lowest floor used solely for parking of vehicles, building access, or storage in an area other than a basement, that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding be provided; and the bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwater. 4. Manufactured Homes. a. All manufactured homes to be placed within all unnumbered and numbered A zones and AE zones, on the community's FIRM shall be required to be installed using methods and practices that minimize flood damage. For the purpose of this requirement, manufactured homes shall be elevated and anchored to resist flotation, collapse or lateral movement. Manufactured homes must be anchored in accordance with State and local building codes and FEMA guidelines. In the event that over-the-top frame ties to ground anchors are used, the following specific requirements (or equivalent) shall be met: (1) Over-the-top ties be provided at each of the four (4) corners of the manufactured home with two (2) additional ties per side at intermediate locations and manufactured homes less than fifty (50) feet long requiring one (1) additional tie per side; (2) Frame ties be provided at each corner of the home with five (5) additional ties per side at intermediate points and manufactured homes less than fifty (50) feet long requiring four (4) additional ties per side; (3) All components of the anchoring system be capable of carrying a force of four thousand eight hundred (4,800) pounds; and (4) Any addition to the manufactured home is similarly anchored. b. All manufactured homes that are placed or substantially improved within Zones A and AE on the community's FIRM, shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is two (2) feet or more above the base flood elevation and be securely anchored to an adequately anchored foundation system in accordance with the provisions of this Section. 5. Recreational Vehicles. Recreational vehicles placed on sites within all unnumbered and numbered A Zones, and AE Zones on the community's FIRM shall either: a. Be on the site for fewer than one hundred eighty (180) consecutive days; or b. Be fully licensed and ready for highway use*; or c. Meet the permitting, elevating and the anchoring requirements for manufactured homes of this Section. * | A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices and has no permanently attached additions.

[R.O. 2008 § 415.190; R.O. 2007 § 415.190; Ord. No. 4974 § 1, 3-30-2006 ; Ord. No. 6206 § 16, 4-28-2016 ]

Ask a question about O'Fallon law

Corpus searches the O'Fallon sections it holds and shows the ones that match, with their citations. Free, no sign-in.