For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 500.020 — Additions, Insertions And Changes

Code of Ordinances, City of O'Fallon, Missouri (Code 2026-10-22) · O'Fallon City Code § 500.020

Corpus is an independent public-information project, not the official City of O'Fallon website. Stable reference: corpuslaw.us/code/d9932f91-3535-4809-80c0-13d417b25f42

Section 500.020: Additions, Insertions And Changes.

The following numbered Subsections of the International Building Code, 2021 Edition, including Appendix K, as published by the International Code Council, Inc., are hereby amended by additions, insertions, deletions and changes so that such Section and Subsections read as follows: (CHAPTER 1 ADMINISTRATION) (SECTION 101 GENERAL) 101.1 Title. These regulations shall be known as the Building Code of the City of O'Fallon, Missouri, hereinafter referred to as "this code." (SECTION 103 CODE COMPLIANCE AGENCY) 103.1 Creation of enforcement agency. The Building and Code Enforcement Department is hereby created, and the official in charge shall be known as the Building Official. (SECTION 105 PERMITS) 105.2 Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. Permits shall not be required for the following: Building: 1. | Retaining walls that are not over 4 feet (1,219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge, impounding Class I, II or IIIA liquids, or altering the channelized drainage of any drainage area or lot. 2. | Water tanks supported directly on grade if the capacity is not greater than 5,000 gallons (18,925 L) and the ratio of height to diameter or width is not greater than 2:1. 3. | Sidewalks and driveways not more than 30 inches (762 mm) above adjacent grade, and not over any basement or story below and are not part of an accessible route. 4. | Painting, papering, tiling, carpeting, cabinets, counter tops, tuckpointing, siding, and similar finish work. 5. | Temporary motion picture, television and theater stage sets and scenery. 6. | Prefabricated swimming pools accessory to a Group R-3 occupancy that are less than 24 inches (610 mm) deep, are not greater than 5,000 gallons (18,925 L) and are installed entirely above ground. 7. | Shade cloth structures constructed for nursery or agricultural purposes, not including service systems. 8. | Window awnings in Group R-3 and U occupancies, supported by an exterior wall that do not project more than 54 inches (1,372 mm) from the exterior wall and do not require additional support. 9. | Nonfixed and movable fixtures, cases, racks, counters and partitions not over 5 feet 9 inches (1,753 mm) in height. 10. | Flag poles less than 35 feet in height. 11. | Replacement of doors and windows where the opening size is not increased or decreased. 12. | Reroofing of asphalt shingle roofs. Electrical: 1. | Repairs and maintenance: Minor repair work, including the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles. 2. | Radio and television transmitting stations: The provisions of this code shall not apply to electrical equipment used for radio and television transmissions but do apply to equipment and wiring for a power supply and the installations of towers and antennas. 3. | Temporary testing systems: A permit shall not be required for the installation of any temporary system required for the testing or servicing of electrical equipment or apparatus. Gas: 1. | Portable heating appliance. 2. | Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe. Mechanical: 1. | Portable heating appliance. 2. | Portable ventilation equipment. 3. | Portable cooling unit. 4. | Steam, hot or chilled water piping within any heating or cooling equipment regulated by this code. 5. | Replacement of any part that does not alter its approval or make it unsafe. 6. | Portable evaporative cooler. 7. | Self-contained refrigeration system containing 10 pounds (4.54 kg) or less of refrigerant and actuated by motors of 1 horsepower (0.75 kW) or less. Plumbing: 1. | The stopping of leaks in drains, water, soil, waste or vent pipe; provided, however, that if any concealed trap, drain pipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered as new work and a permit shall be obtained and inspection made as provided in this code. 2. | Clearing stoppages or repairing leaks in pipes, valves, or fixtures and removing and reinstalling water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes, or fixtures. 3. | Fixture replacement with similar fixtures where plumbing connections are not relocated. (SECTION 107 CONSTRUCTION DOCUMENTS) 107.1.90 Professionally prepared plans. Where required, all plans and specifications shall be prepared, signed and sealed by an architect or engineer licensed and registered in the State of Missouri to render this service. Exceptions: The following exceptions are at the discretion of the Building Official: 1. | Single-family dwelling plans prepared and designed for use by the owner of the proposed structure and built for his exclusive use and occupancy for a period of not less than one (1) year. 2. | Miscellaneous residential structures such as room additions, carports, garages, sheds, etc. (SECTION 109 FEES) 109.2 Schedule of permit fees. Fees related to administering this Code shall be as set forth elsewhere in this Chapter of the Municipal Code. 109.2.90 Integrated permits. The Building Official, at his/her discretion, may issue integrated building, plumbing, electrical and/or mechanical permits. (SECTION 110 INSPECTIONS) 110.90 Workmanship. Repairs, maintenance work, alterations or installations which are caused directly or indirectly by the enforcement of this Code shall be executed and installed in a workmanlike manner in compliance with this Code, in accordance with industry standards, and in accordance with the manufacturer's installation instructions. (SECTION 113 MEANS OF APPEALS) 113.1 General Any applicant shall have the right to appeal a decision of the Building Official to the Board of Adjustment. Application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted there under have been incorrectly interpreted, the provisions of this Code do not fully apply, or an equivalent form of construction is to be used. The appellant shall have the burden to prove that an equivalent form of construction complies with the intent of the provisions of this code, and that the material, method, or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability, and safety. 113.1.90 Board of Appeals. Whenever "Board of Appeals" is used in this Code, it shall mean Board of Adjustment. (SECTION 114 VIOLATIONS) 114.2 Notice of violation. When the Building Official determines that a violation of this Code exists, other than a violation of a stop work order, he/she shall immediately notify the violator. The notification shall be in writing and shall be delivered to the violator or his/her legally authorized representative or mailed 1st Class U.S. Mail to his/her last known address. Any person having been notified that a violation, other than a violation of a stop work order, exists and who fails to abate the violation within ten (10) days after notification shall be subject to the penalties enumerated in Section 114.4. (CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS) (SECTION 506 BUILDING AREA) 506.1.90 Minimum residential dwelling unit areas. The minimum residential dwelling unit area shall be in accordance with Section 500.030. (CHAPTER 12 INTERIOR ENVIRONMENT) (SECTION 1208 INTERIOR SPACE DIMENSIONS) 1208.90 Minimum residential dwelling unit areas. The minimum residential dwelling unit area shall be in accordance with Section 500.030. (CHAPTER 16 STRUCTURAL DESIGN) (SECTION 1612 FLOOD LOADS) 1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the applicable governing authority shall adopt a flood hazard map and supporting data. The flood hazard map shall include, at a minimum, areas of special flood hazard as identified by the Federal Emergency Management Agency in an engineering report entitled The Flood Insurance Study for the "City of O'Fallon," dated January 20, 2016, as amended or revised with the accompanying Flood Insurance Rate Map (FIRM) and related supporting data along with any revisions thereto. The adopted flood hazard map supporting data are hereby adopted by reference and declared to be part of this decision. (CHAPTER 29 PLUMBING SYSTEMS) (SECTION 2902 MINIMUM PLUMBING FACILITIES) 2902.2 Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. Exceptions: 1. | Separate facilities shall not be required for dwelling units and sleeping units. 2. | Separate facilities shall not be required in structures or tenant spaces with a total occupant load, including both employees and customers, of 25 or fewer. 3. | Separate facilities shall not be required in mercantile occupancies in which the maximum occupant load is 100 or fewer. 4. | Separate facilities shall not be required in business occupancies in which the maximum occupant load is 25 or fewer. 5. | Separate facilities shall not be required to be designated by sex where single-user toilets rooms are provided in accordance with Section 2902.1.2. 6. | Separate facilities shall not be required where rooms having both water closets and lavatory fixtures are designed for use by both sexes and privacy for water closets are installed in accordance with Section 405.3.4 of the International Plumbing Code. Urinals shall be located in an area visually separated from the remainder of the facility or each urinal that is provided shall be located in a stall. 7. | Separate facilities shall not be required in structures or tenant spaces functioning solely as exercise facilities with a square footage less than 1500 square feet. (CHAPTER 31 SPECIAL CONSTRUCTION) (SECTION 3107 SIGNS) 3107.1 General. Signs shall be designed, constructed and maintained in accordance with this code and the Municipal Code of the City of O'Fallon, Missouri.

[R.O. 2008 § 500.020; R.O. 2007 § 500.030; Ord. No. 1886 § 6, 2-7-1991 ; Ord. No. 1913 § 1, 4-4-1991 ; Ord. No. 3529 § 6, 5-22-1997 ; Ord. No. 3550 § 2, 7-7-1997 ; Ord. No. 3551 § 3, 7-7-1997 ; Ord. No. 4090 § 6, 7-31-2000 ; Ord. No. 4092 § 2, 7-31-2000 ; Ord. No. 4795 § 2, 4-14-2005 ; Ord. No. 4835 § 2, 5-16-2005 ; Ord. No. 4926 § 2, 11-16-2005 ; Ord. No. 5065 § 1, 10-12-2006 ; Ord. No. 5087 § 1, 11-1-2006 ; Ord. No. 5671 § 1, 2-10-2011 ; Ord. No. 6250 § 1, 9-8-2016 ; Ord. No. 7133 , 9-12-2024

Ask a question about O'Fallon law

Corpus searches the O'Fallon sections it holds and shows the ones that match, with their citations. Free, no sign-in.