§ 110-53 — Methods of load reduction
Code of the City of Springfield, Missouri (Supp. No. 23, Update 2: codified through G.O. No. 6973, enacted January 12, 2026) · Springfield, Mo., City Code § 110-53
Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/a1baff69-30e8-4644-9a4b-0be0472ebaaf
Sec. 110-53. - Methods of load reduction.
(a) Voluntary and mandatory load reduction on anticipated possibility of power shortage. If it can be anticipated at least five hours in advance that there is a distinct possibility of a power shortage, the following plan will be implemented in the order given until it can be determined that the emergency no longer exists: (1) Step 1—Voluntary load reduction (general appeal). An appeal should be made to all local news media stating that a power shortage is probable and requesting all customers to reduce load to the extent possible. A list of specific suggestions should be included, such as: a. Turning off air conditioning equipment or changing the thermostat setting for reduced time of operation. b. Using clothes washing and drying equipment with only full loads and using this equipment before 10:00 a.m. or after 10:00 p.m. c. Using dishwashing equipment with only full loads and using this equipment before 10:00 a.m. or after 10:00 p.m. d. Avoiding use of electric ranges and other electric appliances between 10:00 a.m. and 10:00 p.m. e. Deenergizing power-consuming signs, e.g., at shopping centers, individual businesses, etc. Large customers should also reduce to the extent possible. (2) Step 2—Voluntary rotating appeal. The residential customers will be given a number assignment and notified that they are requested to completely reduce all load during certain hourly periods throughout the day. Residential customers will be divided into four groups, with a decal being placed upon the meter back or fixture. Each of the four groups would be expected to reduce their load 100 percent for one hour three times a day, noncoincidentally, from 10:00 a.m. through 10:00 p.m. (3) Step 3—Mandatory reductions by all affected customers. a. Industrial customers shall be directed to reduce their load by 50 percent; provided, however, that if an industrial customer with a demand exceeding 300 kw has filed in advance with city utilities a detailed plan for a load reduction, which plan has been approved prior to the emergency by the general manager of city utilities, then the reduction directed shall be in accordance with the approved plan. In approving such plan, the general manager shall consider city utilities' necessity for reducing peak loads, the time in which a particular customer can ready its prescribed reduction, the desirability of avoiding spoilage of materials, unnecessarily requiring workers to be temporarily furloughed, and such other factors deemed appropriate by the general manager. b. Commercial customers shall be directed to turn off all air conditioning, exterior lighting not required for public safety, and all power-consuming signs. c. Residential customers shall be directed to turn off all air conditioning units, provided this provision shall not apply if a customer requires air conditioning for health reasons. A customer who is operating air conditioning shall be presumed to be in violation of this subsection, except that a customer who requires air conditioning for health reasons may rebut this presumption by proof of the health needs for air conditioning. (4) Step 4—Mandatory large power user load reduction. The large power customers will be telephoned and directed to curtail all load not required to avoid plant damage from freezing, fire, etc. City utilities may disconnect them if they fail to comply. The customers in the large power user classification will be separated into various categories (light manufacturing, heavy industrial, retail sales, warehousing, etc.). The customers in these categories will be called and directed to reduce load. All calls will be recorded as to date, time, etc. (5) Step 5—Manual and automatic load reduction. The central control point of the electric system, the dispatch office, will manually deenergize substation feeders throughout the system on a preset, rotating schedule. Since transmission line loadings can be affected, the deenergizing of feeders by supervisory equipment will be arranged such that feeders in each quadrant of the system will be opened. One hour's outage time to each feeder should not be too great an inconvenience to the customer and yet be ample time for city utilities' personnel to assess the situation. If the manual deenergizing of substation feeders is not accomplished swiftly enough, selected substations will be deenergized automatically for conditions of frequency deviation. Frequency deviations occur when the load exceeds generation capabilities. Relaying equipment detects the decreasing frequency and causes the equipment to deenergize load. This system is in agreement with the Southwest Power Pool. The load will be deenergized in the following four steps: a. Ten percent load reduction when the frequency drops to 59.3 cycles. b. Ten percent load reduction when the frequency drops to 59 cycles. c. Ten percent load reduction when the frequency drops to 58.7 cycles. d. Separation of interconnections at 58.5 cycles. City utilities has a frequency relay program that follows these steps. (b) Emergencies. In the event of an emergency from any cause, city utilities may proceed immediately to the manual deenergizing of substation feeders set forth in Step 5 in subsection (a)(5) of this section, it being recognized that an emergency can occur without warning and before implementation of the plan set forth. It is further recognized that an anticipated possibility of a power shortage may become an emergency at any state of the plan set forth, and in that event city utilities may immediately proceed to the actions set forth in Step 5 without proceeding through the intermediate steps. (c) Notification of customers. With respect to the mandatory provisions of the plan set forth in this section, a customer shall be deemed to have been notified and directed to reduce the use of electrical energy as set forth in the plan when the general manager of city utilities or his designated representative files such directions at the office of the board of public utilities and causes such notice to be made public through the news media, except that nothing contained in this section shall be deemed to prohibit other means to notify persons of the need to reduce use of electrical energy in accordance with the plan. Upon city utilities taking steps to notify customers as set forth in this subsection, a customer shall be presumed to have notice and shall take steps to comply with the plan, except that a customer may rebut such presumption by showing that the customer did not, in fact, have notice of the directions to comply with the provisions of the plan.
(Code 1981, § 34-24)
Ask a question about Springfield law
Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.