For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 120-113 — Specific pollutant limitations

Code of the City of Springfield, Missouri (Supp. No. 23, Update 2: codified through G.O. No. 6973, enacted January 12, 2026) · Springfield, Mo., City Code § 120-113

Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/e7033ac8-a801-4d3b-ac58-18a341b4e893

Sec. 120-113. - Specific pollutant limitations.

(a) Southwest Wastewater Treatment Plant local discharge limitations. Local discharge limitations for specific pollutants listed in this table are established to protect against pass through and interference. No person shall discharge wastewater containing in excess of the following instantaneous maximum allowable discharge limits: Parameters | mg/l Aluminum—dissolved (A1) | * Antimony (Sb) | * Arsenic (As) | 0.51 Barium (Ba) | * Beryllium (Be) | * Boron (B) | * Cadmium (Cd) | 0.13 Chromium—total (Cr) | 2.91 Chromium—hexavalent (Cr 6+ ) | * Cobalt (Co) | * Copper (Cu) | 2.44 Cyanide (CN) | 0.33 Fluoride (F) | * Iron (Fe) | * Lead (Pb) | 0.53 Manganese (Mn) | * Mercury (Hg) | 0.02 Nickel (Ni) | 5.79 Phenols | * Selenium (Se) | * Silver (Ag) | * Thallium (Tl) | * Zinc (Zn) | 6.54 Total Kjeldahl Nitrogen (TKN) | * Ammonia (NH 3 -N) | * Oil and Grease (animal and/or vegetable) | 100 Total Toxic Organics (T.T.O.) | * Total Dissolved Solids | * Temperature—Maximum (degrees in Fahrenheit)) | 150 pH—Maximum (pH units) | 12.5 pH-Minimum (pH units) | 5.0 Biochemical Oxygen Demand (BOD 5 ) | * Chemical Oxygen Demand (COD) | * Suspended Solids (NFR) | * Flow—(MGD) | * Flashpoint—not less than (degrees in Fahrenheit) | 140 The above limits apply at the point where wastewater is discharged to the POTW. All concentrations for metallic substances are for "total" metal unless indicated otherwise. *No discharge limit is currently warranted for these parameters. The director reserves the right, however, to establish a discharge limit as the need occurs. (b) Northwest Wastewater Treatment Plant local discharge limits. Local discharge limitations for specific pollutants listed in this table are established to protect against pass through and interference. No person shall discharge wastewater containing in excess of the following instantaneous maximum allowable discharge limits: Parameters | mg/l Aluminum—dissolved (A1) | * Antimony (Sb) | * Arsenic (As) | 0.85 Barium (Ba) | * Beryllium (Be) | * Boron (B) | * Cadmium (Cd) | 0.86 Chromium—total (Cr) | 5.43 Chromium—hexavalent (Cr 6+ ) | * Cobalt (Co) | * Copper (Cu) | 1.89 Cyanide (CN) | 0.31 Fluoride (F) | * Iron (Fe) | * Lead (Pb) | 0.95 Manganese (Mn) | * Mercury (Hg) | 0.05 Nickel (Ni) | 19.85 Phenols | * Selenium (Se) | * Silver (Ag) | * Thallium (Tl) | * Zinc (Zn) | 10.60 Total Kjeldahl Nitrogen (TKN) | * Ammonia (NH 3 -N) | * Oil and Grease (animal and/or vegetable) | 100 Total Toxic Organics (T.T.O.) | * Total Dissolved Solids | * Temperature—Maximum (degrees in Fahrenheit)) | 150 pH—Maximum (pH units) | 12.5 pH-Minimum (pH units) | 5.0 Biochemical Oxygen Demand (BOD 5 ) | * Chemical Oxygen Demand (COD) | * Suspended Solids (NFR) | * Flow—(MGD) | * Flashpoint—not less than (degrees in Fahrenheit) | 140 The above limits apply at the point where wastewater is discharged to the POTW. All concentrations for metallic substances are for "total" metal unless indicated otherwise. *No discharge limit is currently warranted for these parameters. The director reserves the right, however, to establish a discharge limit as the need occurs. (c) If, in establishing a discharge restrictions, discharge limits, or pretreatment standards pursuant to this chapter, the director establishes limits to be met by a user, the director in lieu of concentration limits, may establish mass limits of comparable stringency for an individual user at the request of such user. (d) Where process effluent is mixed prior to treatment with wastewaters other than those generated by the categorical regulated process, fixed alternative discharge limits may be derived in accordance with 40 CFR 403.6(e), combined wastestream formula. (e) Categorical pretreatment standards may be adjusted to reflect the presence of pollutants in an industrial user's intake water in accordance with 40 CFR 403.15, net/gross calculation.

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.