§ 120-154 — Determination of wastewater characteristics

Code of the City of Springfield, Missouri (Supp. No. 23, Update 2: codified through G.O. No. 6973, enacted January 12, 2026) · Springfield, Mo., City Code § 120-154

Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/9c23c8df-d02a-4e87-9478-1bae62de144e

Sec. 120-154. - Determination of wastewater characteristics.

(a) Measurements, tests, and analyses of the characteristics of wastewater to which reference is made in this chapter shall be determined in accordance with procedures contained in 40 CFR 136 and amendments thereto, unless otherwise specified in an applicable categorical pretreatment standard, or with any other test procedures approved by the administrator of EPA. Sampling methods, locations, times, durations and frequencies are to be determined on an individual basis subject to approval by the director. (b) Except as indicated in subsection (c) of this section, for all other pollutants, 24-hour composite samples must be obtained through flow-proportional composite sampling techniques, unless time-proportional composite sampling or grab sampling is authorized by the control authority, the samples must be representative of the discharge and the decision to allow the alternative sampling must be documented in the Industrial User file for that facility or facilities. Using protocols (including appropriate preservation) specified in 40 CFR Part 136 and appropriate EPA guidance, multiple grab samples collected during the 24-hour period may be composited prior to the analysis as follows: for cyanide, total phenols, and sulfides the samples may be composited in the laboratory. Composite samples for other parameters unaffected by compositing procedures as documented in approved EPA methodologies may be authorized by the control authority, as appropriate. (c) Samples for oil and grease, temperature, pH, cyanide, phenols, toxicity, sulfides and volatile organic chemicals must be obtained using grab collection techniques. (d) Measurements, tests and analyses of the characteristics of wastewater required by this chapter shall be performed by a laboratory approved by the director. When such analyses are required of a user, the user may, with the approval of the director, make arrangements with a qualified laboratory, including that of the user, to perform such analyses. (e) Monitoring of wastewater characteristics necessary for determination of compliance with this chapter shall be conducted at least semiannually unless more frequent monitoring is required by the director. (f) For sampling required in support of baseline monitoring and 90-day compliance reports, a minimum of four grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide and volatile organic compounds for facilities for which historical sampling data do not exist; for facilities for which historical sampling data are available, the control authority may authorize a lower minimum. For the reports required by 40 CFR 403.12(e) and (h), the control authority shall require the number of grab samples necessary to assess and assure compliance by industrial users with applicable pretreatment standards and requirements. (g) Samples shall be taken immediately downstream from pretreatment facilities if such exist, immediately downstream from the regulated or manufacturing process if no pretreatment exists, or at a location determined by the city and specified in the user's wastewater discharge permit. For categorical users, if other wastewaters are mixed with the regulated wastewater prior to pretreatment, the user shall measure the flows and concentrations necessary to allow use of the combined wastestream formula of 40 CFR 403.6(e) in order to evaluate compliance with the applicable categorical pretreatment standards. For other SIUs, for which the city has adjusted its local limits to factor out dilution flows, the user shall measure the flows and concentrations necessary to evaluate compliance with the adjusted pretreatment standard(s). (h) All sample results shall indicate the time, date and place of sampling, and methods of analysis and shall certify that the wastestream sampled is representative of normal work cycles and expected pollutant discharges from the user. If a user sampled and analyzed more frequently than what was required in its wastewater discharge permit, using methodologies in 40 CFR Part 136, it must submit all results of sampling and analysis of the discharge as part of its self-monitoring report.

(G.O. No. 6488, § 1, 12-10-2018)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.