For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 36-101 — Scope

Code of the City of Springfield, Missouri (Supp. No. 23, Update 2: codified through G.O. No. 6973, enacted January 12, 2026) · Springfield, Mo., Land Development Code § 36-101

Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/9a60924f-ebb0-4069-b3ea-c6c082ae11a0

Sec. 36-101. - Scope.

The regulations of this article shall control all matters concerning, but not limited to, the construction, alterations, addition, repair, removal, moving, demolition, use, location, occupancy and maintenance of all buildings and structures. Provisions in the adopted code appendices shall not apply unless specifically adopted. (1) Scope of International Building Code. The provisions of the International Building Code shall apply to the construction, alteration, relocation, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal, and demolition of every building or structure of any appurtenances connected or attached to such buildings or structures. Exception: a. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures shall comply with the International Residential Code. b. Existing buildings undergoing repair, alterations or additions, and change of occupancy shall be permitted to comply with the International Existing Building Code. (2) Scope of International Fuel Gas Code. The provisions of the International Fuel Gas Code shall apply to the installation, use, and maintenance of fuel gas piping systems, fuel gas appliances, gaseous hydrogen systems, and related accessories as follows: a. Coverage of piping systems shall extend from the point of delivery to the connection point of the appliance. b. Systems with an operating pressure of 125 psig (862 kPa gauge) or less. Piping systems for gas-air mixtures within the flammable range with an operating pressure of ten psig (69 kPa gauge). LP-Gas piping systems with an operating pressure of 20 psig (140 kPa gauge) or less except as provided for in the code. c. Piping systems requirements shall include design, materials, components, fabrication, assembly, installation, testing, inspection, operation, and maintenance. d. Requirements for gas utilization equipment and related accessories shall include installation, combustion and ventilation air, venting, and connections to piping systems. Exception: 1. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures shall comply with the International Residential Code. 2. Fuel-gas piping systems, fuel-gas utilization equipment and related accessories in existing buildings undergoing repair, alterations or additions and change of occupancy shall be permitted to comply with the International Existing Building Code. The International Fuel Gas Code shall not apply to the following: a. Portable LP-Gas appliances and equipment of all types that are not connected to a fixed fuel piping system. b. Installation of farm appliances and equipment such as brooders, dehydrators, dryers, and irrigation equipment. c. Raw material (feedstock) applications except for piping to special atmosphere generators. d. Oxygen-fuel gas cutting and welding systems. e. Industrial gas applications using gases such as acetylene and acetylenic compounds, hydrogen, ammonia, carbon monoxide, oxygen, and nitrogen. f. Petroleum refineries, pipeline compressor or pumping stations, loading terminals, compounding plants, refinery tank farms, and natural gas processing plants. g. Integrated chemical plants or portions of such plants where flammable or combustible liquids or gases are produced by chemical reactions or used in chemical reactions. h. LP-Gas installations at utility gas plants. i. Liquefied natural gas (LNG) installations. j. Fuel gas piping in power and atomic energy plants. k. Proprietary items of equipment, apparatus, or instruments such as gas generating sets, compressors, and calorimeters. l. LP-Gas equipment for vaporization, gas mixing, and gas manufacturing. m. Temporary LP-Gas piping for buildings under construction or renovation that is not to become part of the permanent piping system. n. Installation of LP-Gas systems for railroad switch heating. o. Installation of LP-Gas and compressed natural gas (CNG) systems on vehicles. p. Except as provided in Section 401.1.1 of the International Fuel Gas Code gas piping, meters, gas pressure regulators, and other appurtenances used by the serving gas supplier in the distribution of gas, other than undiluted LP-Gas. q. Building design and construction, except as specified herein. r. Piping systems for mixtures of gas and air within the flammable range with an operating pressure greater than ten psig. s. Portable fuel cell appliances that are neither connected to a fixed piping system nor interconnected to a power grid. (3) Scope of International Mechanical Code. The provisions of the International Mechanical Code shall regulate the design, installation, maintenance, alteration, and inspection of mechanical systems that are permanently installed and utilized to provide control of environmental conditions and related processes within a building. This code shall also regulate those mechanical systems, system components, equipment and appliances specifically addressed herein. The installation of fuel gas distribution piping and equipment, fuel gas-fired appliances and fuel gas-fired appliance venting systems shall be regulated by the International Fuel Gas Code. Exception: a. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures shall comply with the International Residential Code. b. Mechanical systems in existing buildings undergoing repair, alterations or additions, and change of occupancy shall be permitted to comply with the International Existing Building Code. (4) Scope of International Plumbing Code. The provisions of the International Plumbing Code shall apply to the erection, installation, alteration, repairs, relocation, replacement, addition to, use or maintenance of plumbing systems within this jurisdiction. This code shall also regulate nonflammable medical gas, inhalation anesthetic, vacuum piping, nonmedical oxygen systems, and sanitary and condensate vacuum collection systems. The installation of fuel-gas-fired water heaters and water heating venting systems shall be regulated by the adopted International Fuel Gas Code. Exceptions: a. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures shall comply with the International Residential Code. b. Plumbing systems in existing buildings undergoing repair, alterations or additions and change of occupancy shall be permitted to comply with the International Existing Building Code. (5) Scope of International Residential Building Code. The provisions of the International Residential Code for One- and Two-Family Dwellings shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories in height with a separate means of egress and their accessory structures. Exceptions: Existing buildings undergoing repair, alterations or additions, and change of occupancy shall be permitted to comply with the International Existing Building Code. (6) Scope of International Private Sewage Disposal Code. Septic tank and effluent absorption systems or other treatment tank and effluent disposal systems shall be permitted where a public sewer is not available to the property served. Unless specifically approved, the private sewage disposal system of each building shall be entirely separate from and independent of any other building. The use of a common system or a system on a parcel other than the parcel where the structure is located shall be subject to the full requirements of this code as for systems serving public buildings. (7) Scope of NFPA 70, National Electric Code. The NFPA 70, National Electric Code shall regulate the design, construction, installation, alteration, repairs, relocation, replacement, addition to, use or maintenance of electrical systems and equipment. Exceptions: a. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures shall comply with the International Residential Code. b. Electrical systems in existing buildings undergoing repair, alterations or additions, and change of occupancy shall be permitted to comply with the International Existing Building Code. (8) Scope of International Existing Building Code. The provisions of the International Existing Building Code shall apply to the repair, alteration, change of occupancy, addition, and relocation of existing buildings. (9) Scope of International Property Maintenance Code. The provisions of the International Property Maintenance Code shall apply to all existing residential and nonresidential structures and all existing premises and constitute minimum requirements and standards for premises, structures, equipment, and facilities for light, ventilation, space, heating, sanitation, protection from the elements, life safety, safety from fire and other hazards, and for safe and sanitary maintenance. (10) Scope of International Swimming Pool and Spa Code. The provisions of this code shall apply to the construction, alteration, movement, renovation, replacement, repair and maintenance of aquatic recreation facilities, pools and spas. The pools and spas covered by this code are either permanent or temporary and shall be only those that are designed and manufactured to be connected to a circulation system and that are intended for swimming, bathing or wading. Flotation tank systems intended for sensory deprivation therapy shall not be considered to be included in the scope of this code. (11) Scope of International Energy Conservation Code (IECC). The provisions of this code shall apply to commercial buildings and sites not governed by the International Residential Code, and associated systems and equipment. Where a building includes both residential and commercial occupancies, each occupancy shall be separately considered and meet the applicable provisions of IECC—Commercial Provisions or IECC—Residential Provisions. Residential buildings not governed by the residential code shall meet the provisions of IECC—Residential provisions. Commercial buildings shall meet the provisions of International Energy Conservation Code—Commercial Provisions. Exceptions: a. Storm windows installed over existing fenestration. b. Glass only replacements in an existing sash and frame. c. Existing ceiling, wall or floor cavities exposed during construction provide that these cavities are filled with insulation. d. Construction where the existing roof, wall or floor cavity is not exposed. e. Reroofing for roofs where neither the sheathing nor the insulation is exposed. Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing. f. Replacement of existing doors that separate conditioned space from the exterior shall not require the installation of a vestibule or revolving door, provided, however, that an existing vestibule that separates a conditioned space from the exterior shall not be removed. g. Alterations that replace less than 50 percent of the luminaires in a space, provided that such alterations do not increase the installed interior lighting power. h. Alterations that replace only the bulb and ballast within the existing luminaires in a space provided that the alteration does not increase the installed interior lighting power. i. Low energy buildings. The following buildings, or portions thereof, separated from the remainder of the building by building thermal envelope assemblies complying with this code shall be exempt from the building thermal envelope provisions of this code: i. Those with a peak design rate of energy usage less than 15 Btu/h · ft 2 (47.4 W/m 2 ) or 4.4 watt/ft 2 (47.4 W/m 2 ) of floor area for space conditioning purposes. ii. Those that do not contain conditioned space. iii. Occupancies Storage Group S, Utility and Miscellaneous Group U, and Factory Group F provided they are thermally isolated from other occupancies within the same building. The provisions of the IECC shall apply to these other occupancies within the same building. iv. Occupancy classification S-1, S-2, F-1, F-2, U. j. Historic buildings. Any building or structure that is listed in the State or National Register of Historic Places; designated as a historic property under local or state designation law or survey; certified as a contributing resource with a National Register listed or locally designated historic district; or with an opinion or certification that the property is eligible to be listed on the National or State Registers of Historic Places either individually or as a contributing building to a historic district by the State Historic Preservation Officer or the Keeper of the National Register of Historic Places, are exempt from this code.

(Ord. No. 6352, § 1, 3-20-17; Gen. Ord. 6553, § 1, 11-18-19)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.