§ 36-1302 — Deletions, modifications, amendments, and additions

Code of the City of Springfield, Missouri (Supp. No. 23, Update 2: codified through G.O. No. 6973, enacted January 12, 2026) · Springfield, Mo., Land Development Code § 36-1302

Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/a9180769-74ba-43cb-b415-3ae187df3c4e

Sec. 36-1302. - Deletions, modifications, amendments, and additions.

The 2018 International Residential Code, as adopted, is hereby amended and changed as follows: (a) Chapter 1 is repealed in its entirety because code enforcement is covered in Springfield City Code Chapter 36, Land Development Code, Article I, Administration and Enforcement of Codes and Article X, Uniform Enforcement. (b) Because Chapter 1 is repealed in its entirety, any cross references to Chapter 1 in subsequent chapters are replaced by the provisions in Article I that correspond, in content, to such cross references. (c) All adopted chapters and appendices include all errata hereafter published by the International Code Council after the date of the first printing of the 2018 International Residential Code. (d) All language referring to flood-hazard areas is repealed and replaced with: All structures located within a designated flood-hazard area shall comply with Chapter 36 Land Development Code, Article XVII Floodplain Management. The following table is adopted in lieu of the table with the same number and name in the International Residential Code. TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Load | 20 PSF Wind Speed (mph) | 115 MPH Seismic Design Category | B Weathering | Severe Frost Line Depth | 24 inches Termite | Moderate to Heavy Decay | Slight to Moderate Ice Shield Underlayment Required | No Flood Hazard | In accordance with Springfield MO City Code Chapter 36 Article XVII https://library.municode.com/mo/springfield/codes/code of ordinances Entry into National Flood Insurance Program 5/8/1989 Air Freezing Index | 659 Winter Design Temp | 9° F Air Freezing Index | 1,500 or less Mean Annual Temp | 56° F Elevation | 1,270 feet Latitude | 37° N Winter Heating | 11° F Summer Cooling | 92° F Altitude Correction Factor | 0.96 Indoor Design Temperature | 70° F Wind Velocity Heating | 15 mph if site specific speed unknown Wind Velocity Cooling | 15 mph if site specific speed unknown Coincident Wet Bulb | 74° F Daily Range | M Section R313 Automatic Fire Sprinkler Systems is deleted in its entirety and replaced with: A builder of five (5) or more connected units shall comply with the design and installation requirements of the 2018 International Residential Code Section P2904. The builder of four (4) or less connected units shall comply with fire suppressant separation as provided in Section R317 of the 2006 International Residential Code or Section P2904 of the 2018 International Residential Code at the builder or purchaser's cost and option. The following table is adopted in lieu of the table with the same number and name in the International Residential Code: TABLE N1102.1.2 (R402.1.2) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT FENESTRATION U-FACTOR b | 0.32 SKYLIGHT b U-FACTOR | 0.55 GLAZED FENESTRATION SHGC b, e | 0.40 CEILING R-VALUE | 49 WOOD FRAME WALL R-VALUE | 20 or 13+5 h MASS WALL R-VALUE i | 8/13 FLOOR R-VALUE | Not Required BASEMENT c WALL R-VALUE | 10/13 f SLAB d R-VALUE & DEPTH | 10, 2 ft CRAWL SPACE c R- VALUE | 10/13 The following table is adopted in lieu of the table with the same number and name in the International Residential Code: TABLE N1102.1.4 (R402.1.4) EQUIVALENT U-FACTORS FENESTRATION U-FACTOR | 0.32 SKYLIGHT U-FACTOR | 0.55 CEILING U-FACTOR | 0.026 FRAME WALL U-FACTOR | 0.060 MASS WALL U-FACTOR b | 0.098 FLOOR U-FACTOR | Not Required BASEMENT WALL U-FACTOR | 0.059 CRAWL SPACE U-FACTOR | 0.065 N1102.4.1.2 (R402.4.1.2) Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding five air changes per hour in Climate Zones 1 and 2, and five air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with RESNET/ICC 380, ASTM E779 or ASTM E1827 and reported at a pressure of 0.2-inch w.g. (50 Pascals). Where required by the building official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the building official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Table N1105.5.2(1) Air exchange rate Climate Zones 3 through 8: 5 air changes per hour. P3302.2 Subsoil drains discharge. Subsoil drains, sumps and pumps shall not be discharged to the building drain or sewer. E3902.2 Garage and accessory building receptacles. 125-volt, single-phase, 15- or 20- ampere receptacles installed in garages and grade-level portions of unfinished accessory buildings used for storage or work areas shall have ground-fault circuit-interrupter protection for personnel. [210.8(A)(2)] Exception: A single receptacle installed solely for electrical supply of a garage door opener. E3902.16 Arc-fault circuit-interrupter protection. Branch circuits that supply 120-volt, single-phase, 15- and 20-ampere outlets installed in bedrooms, and similar rooms or areas shall be protected by any of the following: [210.12(A)] E4002.14 Tamper-resistant receptacles. In bedrooms, 15- and 20-ampere, 125- and 250-volt nonlocking-type receptacles shall be listed tamper-resistant receptacles. [406.12(A)]

(G.O. 6736, § 1, 8-8-22)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.