§ 36-466 — Telecommunication towers
Code of the City of Springfield, Missouri (Supp. No. 23, Update 2: codified through G.O. No. 6973, enacted January 12, 2026) · Springfield, Mo., Land Development Code § 36-466
Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/b98ddd5f-dd9d-4e00-b4c7-d88654e841ec
Sec. 36-466. - Telecommunication towers.
(1) Legislative findings. On February 8, 1996, Congress enacted the federal Telecommunications Act of 1996, P.L. No. 104-458. The purpose of the Act is to deregulate the telecommunications industry, providing a more competitive environment for wired and wireless telecommunication services in the United States. (a) A concomitant effect of increased competition in the market for wireless telecommunications services is an increased demand for antenna sites on towers and other antenna support structures necessary for providing wireless service. (b) New personal wireless telecommunications technologies, such as personal communications systems, or (PCS) require antenna sites to be denser than previous technologies required. However, due to the uniqueness of the wireless telecommunications industry and constantly changing technology, local regulatory efforts must be sufficiently flexible to allow for the continuing development of the wireless telecommunications industry. (c) The Telecommunications Act of 1996 preserves the authority of the city to regulate the placement, construction, and modification of towers, antenna support structures and telecommunications facilities and to protect the health, safety and welfare of the public and which is granted to the city under the Constitution and statutes of the State of Missouri and the Charter. (d) Consistent with the Telecommunications Act of 1996, regulation of towers and telecommunications facilities in certain areas of the City of Springfield as provided in this article, will not have the effect of prohibiting any person from providing wireless telecommunications services. (e) The Federal Communications Commission (FCC) has exclusive jurisdiction over: 1. The regulation of the environmental effects of radio frequency emissions from telecommunications facilities. 2. The regulation of radio signal interference among users of the radio frequency spectrum. (f) The uncontrolled proliferation of towers in the City of Springfield could diminish property values, the aesthetic quality of the city, and could otherwise threaten the health, safety, and welfare of the public. (G) The presence of telecommunications towers, large enclosures, satellite dishes and other large unmovable objects other than standard wood utility poles on the rights-of-way, rather than on private utility easements or fee simple title interests are a danger to the traveling public and an interference with the use and enjoyment of the rights-of-way by abutting landowners and members of the public. (2) Legislative purposes. The general purpose of this section 36-466, telecommunication towers, is to regulate the placement, construction, and modification of towers and telecommunications facilities in order to protect the health, safety, and welfare of the public, while at the same time not unreasonably interfering with the development of the competitive wireless telecommunications marketplace in Springfield. Specifically, the purposes of this section 36-466, telecommunication towers, are: (a) To direct the location of towers and telecommunications facilities in the city; (b) To protect residential areas and land uses from potential adverse impacts of towers and telecommunications facilities; (c) To minimize adverse visual impacts of towers and telecommunications facilities through careful design, sitting, landscaping, and innovative camouflaging techniques; (d) To promote and encourage shared use/collocation of towers and antenna support structures as a primary option rather than construction of additional single-use towers; (e) To avoid potential damage to adjacent properties caused by towers and telecommunications facilities by ensuring such structures are soundly and carefully designed, constructed, modified, maintained and removed. (f) To the greatest extent feasible, ensure that towers and telecommunications facilities are compatible with surrounding land uses. (g) To the greatest extent feasible, ensure that proposed towers and telecommunications facilities are designed in harmony with natural settings and in a manner consistent with current development patterns. (h) To create a licensing process which allows the city to more efficiently administer this section 36-466, telecommunication towers. (3) Applicability. (a) All towers, antenna support structures and telecommunications facilities, any portion of which are located within the City of Springfield, are subject to this article. All towers within the City of Springfield, Missouri at the time of passage of said ordinance, or are annexed at a later date, shall be registered with the city finance director within 60 days from the effective date hereof together with the height, width and location thereof and a registration fee of $50.00. Failure to register an existing tower shall raise a presumption that said tower, was not a legal nonconforming use on the date of passage of said ordinance. However, said ordinance shall not apply to tower structures used, or to be used, solely for services provided pursuant to a broadcast radio or television license issued by the Federal Communications Commission or to towers and antennas used for private telecommunications services when the equipment is located on the premises of the entity using said private telecommunication service, or the towers and antennas, support structure or masts are located on the primary business premises of a provider of communications services if used to monitor the provider's services and the equipment used by the broadcaster, private telecommunicator or provider is in compliance with any federal, state or local laws, and does not encroach on the public rights-of-way. (b) Except as provided in this section 36-466, telecommunication towers, any current legal use being made of an existing tower or antenna support structure on the effective date of this section 36-466, telecommunication towers, (herein "nonconforming structures") shall be allowed to continue, even if in conflict with the terms of this section 36-466, telecommunication towers. Any tower site that has received city approval in the form of either a conditional use permit or building permit, but has not yet been constructed or located, shall be considered a nonconforming structure so long as such approval is current and not expired. (4) Definitions. For the purposes of this article, the following terms, phrases, words, and their derivations shall have the meaning given herein. When not inconsistent with the context, words in the singular number include the plural number. The word "shall" is always mandatory and not merely directory. The word "may" is directory and discretionary and not mandatory. (a) Act means the federal Communications Act of 1934 as amended by the Telecommunications Act of 1996 and as may, from time to time, be amended. (b) Antenna support structure means any building or other structure other than a tower which can be used for location of wireless telecommunications facilities. (c) Applicant means any person that applies for a tower license pursuant to subsection 36-466(8) of this article. (d) Application means the process by which an applicant submits a request and indicates a desire to be granted a license to construct, own, or operate a tower within the city. An Application includes all written documentation made by an applicant to the city concerning such a request. (e) City means the City of Springfield, a municipal corporation, in the State of Missouri, acting by and through its city manager or his designee. (f) Code means the City of Springfield Code of Ordinances. (g) Communications or telecommunications means the transmission, between or among points as specified by the user, of information of the user's choosing, without change in the form or content of the information as sent or received, by wire, radio, optical cable, electronic impulses, or other similar means. As used in this definition, "information" means knowledge or intelligence represented by any form of writing, signs, signals, pictures, sounds, or any other symbols. (h) Council means the Springfield, Missouri, City Council. (i) Director means the director of department of building development services. (j) Engineer means any engineer licensed by the State of Missouri. (k) FCC means the Federal Communications Commission and any legally appointed, designated, or elected agent or successor. (l) Licensee means any person who has lawfully obtained a tower license pursuant to subsection 36-463(8). (m) Person is any natural person, firm, partnership, association, corporation, company, or other legal entity, private or public, whether for profit or not-for-profit. (n) Site means the actual location of a tower and may be only part of a larger parcel or premises. (o) Stealth means any tower or telecommunications facilities which are designed to blend into the surrounding environment. (p) Telecommunications facilities means any cables, wires, lines, wave guides, antennas and any other equipment or facilities associated with the wireless transmission or reception of wireless telecommunications as authorized by the FCC which a person seeks to locate or has installed upon a tower or antenna support structure. However, the term telecommunications facilities shall not include: 1. Any satellite earth station antenna two meters in diameter or less which is located in an area zoned and used for industrial or commercial purposes; 2. Any satellite earth station antenna one meter or less in diameter, regardless of zoning category; 3. Any satellite earth station in excess of two meters in diameter which is utilized for the reception of broadcast television, video or radio signals and which is an ancillary use to a structure on the premises of the holder of the broadcast license. (q) Tower means a self-supporting lattice, guyed or monopole structure constructed from grade which supports wireless telecommunications facilities. The term "tower" shall not include amateur radio operators' equipment, as licensed by the Federal Communications Commission. The "term" tower does not include utility poles that are owned by a utility provider and are primarily utilized for the support of electrical, telephone, cable television, street lighting, or other similar cables or wireless telecommunications facilities, are located on public rights-of-way or easements for that purpose and are a part of a system of such utility poles throughout the City of Springfield, Missouri. (5) Permitted, conditional, and accessory uses. (a) Generally. The allowable use of towers and placement of telecommunications facilities as either permitted uses or conditional uses in the several zoning districts shall be as set forth in this article based on the following table except that no telecommunications towers shall be allowed on any right-of-way. All other utility facilities, regardless of type, shall meet the standards and requirements of the zoning district in which they are located. Any utility facility, equipment, or structure that is to be located above ground on the public right-of-way or private easement with a length or width in excess of 47 inches must receive approval of the council prior to installation. Multiple locations may be approved in one application process. Tier | Wireless Facilities and Telecommunications Towers I | Wireless facilities and antennas mounted on buildings or other structures, including existing towers, public buildings and structures, school buildings and structures, and churches. II | Cell towers of a stealth design that are not greater than 60 feet in height, located on the same premises or parcel as public buildings and structures, school buildings and facilities, church buildings and noncommercial, not-for-profit residential neighborhood facilities and approved by ordinance. III | Cell tower of a monopole or stealth design that are less than 100 feet in height. IV | Cell towers of a stealth or monopole design that are 100 feet or greater in height. V | Cell towers that are: a. Not of a stealth or monopole design; or b. One hundred feet or greater in height and not setback from any residential district at least two feet for every one foot of height; or c. Not able to collocate at least one additional provider if the tower height is 100 feet or greater or at least two additional providers' facilities if the tower height is 120 feet or greater. (b) Telecommunications facilities. Any telecommunications facilities which are not attached to a tower shall be a permitted accessory use to any commercial, industrial, professional, institutional, or multifamily structure, regardless of the zoning restrictions applicable to the zoning district where the structure is located and without having to obtain any prior authorization from the city; provided that the person making such accessory use files a written certification with the city establishing the following: 1. That the total height of the antenna support structure and telecommunications facilities do not exceed the structural height limitations in the applicable zoning district under this article by more than 20 feet; 2. That the antenna support structure and telecommunications facilities comply with the city building code and any applicable state law, does not encroach on the public rights-of-way, and a building permit has been obtained from the department of building development services; and 3. That any telecommunications facilities and antennas located on the roof of a building shall comply with setbacks required by the city building code, if any, and do not extend more than 50 inches in the horizontal plane from the side of such an antenna support structure unless the purpose of said protrusion is to permit signal coverage in an area that will not receive such coverage but for an extension beyond 50 inches. Any extension beyond 50 inches must be approved by the administrative review committee of the city prior to construction of said antenna and such approval shall be dependent upon a showing that coverage is unavailable but for the extension, the extension does not violate any other building code of the city, state or federal law that is applicable, encroach upon public rights-of-way and does not pose any danger to the traveling public. 4. That the telecommunications facilities will utilize camouflaging techniques or will be side-mounted to an antenna support structure in order that the telecommunications facilities harmonize with the character and environment of the area in which they are located if technically feasible and such techniques will not degrade or distort the service signal. Antennas and support structures shall be painted to blend with the color of the building if such painting will not interfere with functioning of the antenna or support structure. (6) Collocation. (a) Collocation of facilities. New towers constructed within the city with height in excess of 60 feet should be capable of accommodating two additional carriers or telecommunications facilities for more than one other provider of communications services (hereinafter referred to as "additional capacity"). Such additional capacity, if any, shall be designated on the application and site plans presented to the city prior to construction of the tower. (b) Collocation or installation. 1. Any licensee whose tower in excess of 60 feet which is constructed after the effective date of this section and which has been built in accordance with setbacks and special conditions granted to towers with collocation capabilities under this Article, and has available additional capacity for installation or collocation of telecommunications facilities as demonstrated at the time the application for construction was granted, shall agree to allow other persons to install or collocate telecommunications facilities on such a tower subject to reasonable terms and conditions negotiated between the parties including the suitability of the proposed tenant, the credit worthiness and technical abilities of the proposed tenant. However, in no event shall a licensee be required to allow collocation of facilities if to do so would result in technical interference with the delivery of licensee's service. Failure to permit collocation or joint use on a tower which has been built in accordance with setbacks and special conditions permitted for towers designed for collocation may result in any enforcement action as permitted in subsections 36-335(2), 36-335(3), 36-335(4), 36-335(5), 36-335(6) and 36-355(7) or termination of utilities following a hearing as permitted in subsection 36-466(6)(f) hereof. 2. For the purpose of collocation of antennas, a legal nonconforming tower may be used. 3. Failure to comply with the provisions of this subsection 36-466(6)(b) constitutes a material violation of this section 36-466, telecommunication towers, et seq., for the purposes of subsection 36-466(9). (c) Exception from height and bufferyards/requirements for collocation. 1. A licensee of an existing tower may modify the height of its tower to accommodate collocation of additional telecommunications facilities as long as the total height of the tower and telecommunications facilities attached thereto do not exceed the maximum height allowed in the applicable zoning district under the code by more than 20 feet. 2. Permission to exceed the maximum permitted height pursuant to this section shall not require an additional distance separation as set forth in subsection 36-466(7)(c)5, nor additional buffer yards or landscaping above that required for the original tower. The tower's premodification height shall be used to calculate such distance separations. (d) Same tower type. A tower which is modified to accommodate the collocation of additional telecommunications facilities shall be of the same tower type as the existing tower. However, a different type of tower may be permitted by the approval of the administrative review committee if it is demonstrated that permitting a different tower type will not exceed the height permitted in subsection 36-466(6)(c), and will permit the collocation of more carriers than could be accomplished by the modification of the same tower type as the existing tower. (e) Movement of tower. 1. A tower which is being rebuilt to accommodate the collocation of additional telecommunications facilities may be moved on the same premises as it was constructed on, or an adjacent premises, within 50 feet of its existing location as long as required setbacks and buffer yards are maintained. 2. A tower that is relocated pursuant to subsection 36-466(6)(e)1 hereof shall continue to be measured from the original tower site for the purpose of calculating the separation distances between towers pursuant to subsection 36-466(7)(c)5. The relocation of a tower under this subsection shall in no way be deemed to cause a violation of subsection 36-466(7)(c)5. 3. A tower that is relocated on the same premises it was constructed on which comes within the separation distances established in subsection 36-466(7)(c)5 shall only be permitted when notarized written consent is obtained from affected residential property owners. (f) Appeal process. Any applicant who is denied a tower application, or who is determined by the director of building development services to be in violation of this section shall have the right of a hearing before an administrative hearing examiner appointed by the city manager and mutually agreeable to the applicant or tower owner. Said hearing examiner shall set the hearing date no later than 20 days following the denial of an application, or the determination of a violation and shall consider, in addition to a determination of whether or not a violation exists or the application was improperly denied, the question of the technical or economic feasibility of compliance with this section. In the event the hearing examiner finds that the tower was constructed in accordance with setback and other provisions relating to towers designed for collocation, and said tower is not being made available for joint use or collocation as indicated at the time of application, the hearing examiner shall order utilities disconnected until such time as the tower is used jointly for collocation as originally stated in the application. The hearing examiner's final decision shall be subject to review pursuant to Chapter 536, RSMo. Any appeal under said chapter shall be filed within 30 days from the date of the hearing examiner's decision. Enforcement of the decision of the hearing examiner may be stayed by the posting of a supersedes bond in an amount determined by the hearing examiner to be sufficient under the facts of the case to protect the interests of the public and any third party in the matter whose rights would be adversely affected by such a stay as demonstrated during any hearing on a request for said bond. (7) Construction standards. (a) Setbacks. 1. All towers shall be set back a distance equal to: a. Fifty percent of the height of the tower up to 100 feet, plus one foot for each foot over 100 feet in height; or b. The distance between the tower base and guy wire anchors, whichever is greater, with the guy wire anchors set back at least 25 feet from adjoining residential districts, public property or a street or at least the rear yard setback from adjoining land in other districts, unless the tower is designed for collocation. In the event a tower is capable of being used for collocation for at least two additional carriers, the setbacks for structures in the zoning district where the tower is located shall be complied with for the tower base and any guy wire anchors. 2. Setback requirements for towers shall be measured from the center of the tower to the property line of the parcel on which it is located. (b) Structural requirements. All towers must be designed and certified by an engineer to be structurally sound and, at minimum, in conformance with the city's building code, any applicable state and federal laws, and other standards outlined in the City Code. A building permit must be obtained before construction may begin. (c) Separation or buffer requirements. 1. Towers shall be separated from the types of areas and comply with the minimum standards established in the table set forth below unless: (1) constructed on the same site as another tower designed for the same purpose, (2) the second tower is permitted by the zoning district, and (3) the height of the second tower does not exceed the height permitted in the zoning district where the tower is to be located: Designated Area | Separation Distance Single-family or duplex residential units in a residential district 1 | 300 feet. If the tower is of a stealth design or is designed for collocation of an additional carrier, then the separation distance may be reduced to 100 percent of the height of the tower. Vacant single-family or duplex residentially zoned land which is either platted or has preliminary subdivision plan approval which is not expired | 300 feet. If the tower is of a stealth design or is designed for collocation of an additional carrier, then the separation distance may be reduced to 100 percent of the height of the tower. Vacant unplatted residentially zoned land and residential units in nonresidential zoned districts 3 | 200 feet or 100 percent of tower 2 , whichever is greater. Existing multifamily residential units greater than duplex units | 100 feet or 100 percent height of tower, whichever is greater. Nonresidentially zoned lands or nonresidential uses | None; only setbacks apply. Approved heliports | 100 feet or 100 percent of the height of tower, whichever is greater. 1 Includes modular homes and mobile homes used for living purposes. Separation from a unit for purposes of this chart is to be measured from the edge of the building or structure itself. 2 Separation measured from the center of the tower to closest building setback line. 3 Includes any unplatted residential use properties without a valid preliminary plat or valid development plan approval and any multifamily residentially zoned land greater than duplex. 2. The minimum tower separation distances above listed shall be calculated and applied irrespective of city and county jurisdictional boundaries. 3. Measurement of tower separation distances for the purpose of compliance with this section 36-466, telecommunication towers, shall be measured from the center of a tower to the closest point of a designated area as specified in the table above set forth. 4. Separation distances from other uses set forth in this subsection may be reduced for towers designed for the collocation of telecommunications facilities of other carriers by obtaining a conditional use permit which will require demonstrating that the separation distances will: a. Have the effect of preventing service to an area of the city; or b. Constitute a barrier to entry into the market place by the applicant; or c. Will constitute a technical or economic hardship on the applicant. Additionally the applicant must demonstrate that (1) the location, shape, appearance or nature of use of the proposed tower will not substantially detract from the aesthetics of the area nor change the character of the neighborhood in which the tower is proposed to be located, and that landscaping techniques will be used to screen the tower from any adjacent residential use, and (2) the proposed tower will accommodate at least two additional carriers of various telecommunications services. The city council shall consider the information presented by the applicant and determine if a special exception would conflict with the purposes of this section, would create a blight on adjacent property, or interfere with adjacent uses, within the separation area. If the tower requires a use permit, then said showing shall be made to the planning and zoning commission and city council as a part of the conditional use permit process. 5. Proposed towers must meet the following minimum separation requirements from towers existing at the time a license is granted pursuant to section 36-466, telecommunication towers, unless constructed for the purpose of providing collocation capacity on the same site as another tower designed for the same purpose, the second tower is permitted by the zoning district, and the height of the second tower does not exceed the height permitted in the zoning district where the tower is to be located. However, an exception from separation distances between towers may be obtained from city council if the applicant can demonstrate that such an exception is necessary for the engineering design of the system the tower is to be a part of, or that no other option is available to provide coverage for the service area. An exception to the separation requirements shall be approved or denied by ordinance. EXISTING TOWERS-TYPES Lattice or Guyed 150 ft. in Height or Greater | Lattice or Guyed less than 150 ft. in Height | Monopole towers 75 ft. in Height or Greater | Monopole Towers Less Than 75 ft. in Height PROPOSED TOWERS-TYPES | Lattice | 3,000 ft. | 2,500 ft. | 1,500 ft. | 750 ft. Guyed | 3,000 ft. | 2,500 ft. | 1,500 ft. | 750 ft. Monopole 75 ft. in height or greater | 1,500 ft. | 1,500 ft. | 1,500 ft. | 750 ft. Monopole less than 75 ft. in height | 750 ft. | 750 ft. | 750 ft. | 750 ft. For the purpose of this subsection, the separation distances shall be measured by drawing or following a straight line between the center of the existing tower and the center, of the proposed tower. (d) Method of determining tower height. The height of the tower shall be measured as follows: The vertical distance between the highest point of the tower and the natural grade below this point. (e) Illumination. Towers shall not be artificially lighted except as required by the Federal Aviation Administration (FAA) and provisions of the City Code except that seasonal lighting may be permitted as approved by the city. At time of construction of a tower, dual mode lighting shall be requested from the FAA in cases where there are residential uses located within a distance from the proposed tower which is equal to three times the proposed height of the tower. (f) Finished color and tower markings. Towers not requiring FAA painting or marking shall have either a galvanized steel finish or be painted an off-white, light gray, silver or white finish. No commercial signs or advertising shall be allowed on any towers or telecommunications facilities. (g) Fencing and screening. Fences must be constructed around or upon parcels containing towers, antenna support structures or telecommunications facilities and shall be constructed in accordance with section 36-480, screening and fencing, of this article. (h) Bufferyard and landscape. All landscaping on parcels containing towers, antenna support structures or telecommunications facilities shall be in accordance with the applicable buffer yard requirements in the zoning district where the tower, antenna support structure of telecommunications facilities are located. Existing vegetation shall be maintained to the extent possible. However, the city may require additional landscaping if to do so would make the tower, antenna support structure or telecommunications facility more reasonably compatible with the surrounding area, but in no event shall additional landscaping exceed any bufferyard requirements as set out in sections 36-482, landscaping and bufferyards, et seq., and, if a conditional use permit is required, subsection 36-363(10)(b)1. All vegetation used in the landscaping shall be located outside any fenced area. (i) Security. All towers must be secured to protect against trespass or unauthorized use of the property, tower, or telecommunications facilities. 1. If high voltage is necessary for the operation of a tower or telecommunications facilities and it is presented in a ground grid or in the tower, warning signs shall be permanently attached to the exterior side of the perimeter fence and located every 25 feet. The signs shall display in bold letters at least eight inches high the following: "HIGH VOLTAGE: DANGER" 2. Identification tags or signs shall be posted on all communications towers and telecommunications facilities in accordance with FCC and OSHA requirements. The tags shall include the FCC tower registration number, the latitude and longitude of the tower, and the name, address, and telephone number of the tower owner. The identification tags shall be posted on the perimeter fence and shall be constructed of durable materials. (j) Access. All parcels upon which towers are located must provide access to at least two vehicular parking spaces located within 100 feet of the tower. Traffic associated with the facility shall not adversely affect traffic on adjacent streets. (k) Interference with public safety radio services. In order to ensure that the city's public safety radio services will be free from objectionable technical interference, all applicants requesting a permit to site a tower or telecommunications facilities shall agree: 1. To demonstrate compliance with good engineering practices; 2. To provide the city a copy of all intermodulation studies submitted to the FCC; 3. Not to induce objectionable technical interference to the city's public safety radio services; 4. To comply with FCC regulations regarding susceptibility to radio frequency interference, frequency coordination requirements, general technical standards for power, antenna, bandwidth limitations, frequency stability, transmitter measurements, operating requirements, and any and all other federal statutory and regulatory requirements relating to radio frequency interference (RFI); 5. In the case of co-location of telecommunications facilities either in the same location or on the same tower as the city's, to not cause or permit to be caused by its transmissions or other activities on the premises, objectionable technical inference of any kind whatsoever to the broadcasting transmission, reception, or electromagnetic communications of the city; 6. To pay for any studies requested by the city manager to determine if the applicant's telecommunications facilities are causing objectionable technical interference; 7. Upon notification by the city manager, if the operations of the applicant are causing objectionable technical interferences, to immediately undertake all steps necessary to determine the cause of and eliminate such interference at the cost of the applicant. If said interference continues for a period in excess of 48 hours after notice from the city manager, the city shall have the right to cause the applicant to cease operating the equipment that is causing the objectionable technical interference or to reduce the power sufficiently to ameliorate the objectionable technical interference until the condition causing said interference has abated. (l) Certifications and inspections. 1. All towers shall be certified by a structural engineer to be structurally sound and in conformance with the requirements of the city building code and all other construction standards set forth by the City's Code and federal and state law. For new monopole towers, such certification shall be submitted with an application pursuant to subsection 36-466(8)(b)1 and every ten years thereafter; for existing monopole towers, such certification shall be submitted within 60 days of the effective date of said ordinance and then every ten years thereafter; for new lattice or guyed towers, such certification shall be submitted with an application pursuant to subsection 36-466(8)(b)1 and every ten years thereafter; and for existing lattice or guyed towers, such certification shall be submitted within 60 days of the effective date of said ordinance and then every ten years thereafter. The tower owner may be required by the city to submit more frequent certifications should there be reason to believe that the structural and electrical integrity of the tower is or has been jeopardized. 2. The city and its agents shall have authority to enter onto the property upon which a tower is located, between the inspections and certifications required above, to inspect the tower for the purpose of determining whether it complies with the city's building code and all other construction standards provided by the City's Code and federal and state law. 3. The city reserves the right to conduct such inspections at any time, upon reasonable notice to the tower ordinance. All expenses related to such inspections by the city shall be borne by the tower owner. (m) Maintenance. 1. Licensees shall at all times employ ordinary and reasonable care and shall install and maintain in use nothing less than commonly accepted methods and devices for preventing failures and accidents which are likely to cause damage, injuries, or nuisances to the public. 2. Licensees shall install and maintain towers, telecommunications facilities, wire, cables, fixtures, and other equipment in compliance with the requirements of the National Electric Safety Code and all FCC, state and local regulations, and in such manner that will not interfere with the use of other property. 3. All towers, telecommunications facilities and antenna support structures shall at all times be kept and maintained in good condition, order, and repair so that the same shall not menace or endanger the life or property of any person. (n) Drainage. All parcels upon which towers are located must contain adequate drainage facilities, which are approved by the director of public works. (o) Stealth design. All licensees shall make every reasonable effort to design and construct new towers and telecommunications facilities to blend into the character and environment of the area in which they are located, including the use of camouflage techniques, path array antennas and side mounting antennas unless such use shall create a hazard for the traveling public or it is not technically feasible to use such design and collocate other facilities on the tower. (8) Licensing requirement. (a) License required. No person may own or operate a tower, or place wireless telecommunications facilities on a tower, without first obtaining from the city a license to do so pursuant to this section (herein referred to as "tower license" or "license"). This requirement applies both to new towers and to existing towers or nonconforming structures on the date of passage of this section. Unless otherwise expressly provided elsewhere in this section 36-466, telecommunication towers, the license required by this section is in addition to the procedures and approval required pursuant to this article of the City Code pertaining to zoning and development and the requirement for a building permit to construct the tower itself. A license may be denied if the applicant is not in compliance with section 20-146 or any other provision of the Springfield City Code regarding the use or provision of towers, telecommunications services or public property, health or safety. The license required under this section shall not be in lieu of a license to conduct business in the City of Springfield, Missouri. Owners of existing towers shall have six months from passage of said ordinance to obtain a license as required by this subsection. A license shall be for a term of not more than five years. A renewal must be made in compliance with this section 36-466, telecommunication towers, and an applicant must demonstrate an existing tower or telecommunications facilities are needed and reasonable alternatives will not meet their needs for continued service capability. (b) Applications. In order to construct and operate a tower after the effective date of this section, a person must file the following applications: The application shall also provide the following: 1. License application. Prior to the construction of any tower, a license application and fee in the amount of $200.00 shall be submitted to the director of finance. This is an initial license application fee and an additional fee shall be due from the applicant should the city's actual costs of approval of the license exceed the fee of $200.00. The city reserves the right to employ an outside consultant to review any application. The applicant shall submit a fee in the amount of the city's estimated expense related to such review as an additional application fee prior to the city incurring such expenses. All tower license applications shall include the following information and documentation: a. The name, address, and telephone number of the applicant. If the applicant is not the owner of the parcel of land upon which the tower is situated, the written consent of the owner, and the name, address, telephone number of the owner, shall be evidenced in the application. The application shall also contain an affirmative statement indicating that both the owner and applicant are aware of and agree to comply with the provision of subsection 36-466(11) regarding abandonment. b. An affirmative statement of whether or not the applicant will be developing the tower for its own use or for the use of others. (i) If for applicant's use, the following is required: A. A description of the use. B. A description of the network the proposed tower will be part of. C. A description of the technological design proposed and description of alternatives. D. Evidence of drive-by tests or other studies relating to the proposed tower which support location on the proposed property. E. Construction date or schedule. (ii) If the applicant is developing the proposed tower for the use of another, in addition to the information required in paragraph "a", the applicant will identify whether or not the intended tower use is based on a lease or other contract or for speculation. The city may require evidence of the schedule for implementing the use of a tower and commitments for its use. c. The legal description, parcel identification number, and address of the parcel of land upon which the tower is to be situated. d. The names, addresses and telephone numbers of all owners of other towers or useable antenna support structures which are capable of providing a location to construct the telecommunications facilities that are planned to be housed or located on the tower within a 3,000-foot radius of the proposed new tower site, including city-owned property. e. Written documentation that the applicant made diligent, but unsuccessful efforts for permission to install or collocate the applicant's telecommunications facilities on city-owned towers or useable antenna support structures or made diligent, but unsuccessful efforts to install or collocate the applicant's telecommunications facilities on towers or useable antenna support structures owned by other persons. f. Written documentation containing the following information: (i) Whether the applicant's telecommunications facilities are technically capable of being installed or collocated on another person's tower or useable antenna support structure. (ii) If the applicant asserts that its telecommunications facilities are economically or technically infeasible of being installed or collocated on another person's tower or useable antenna support structure, a written statement from the applicant setting forth in detail the reason(s) with regard to each person contacted, why such installation or collocation is technically or economically infeasible. "Technically infeasible" for the purpose of this subsection means that the collocation or installation of applicant's telecommunications facilities on another person's tower or useable antenna support structure would not comply with sound engineering principles, would materially degrade or unreasonably impair the tower or useable antenna support structure's current or planned use, or interfere operationally with applicant's planned use. City may require additional evidence of collocation being technically infeasible if, in the opinion of the administrative review committee that additional information is necessary to determine that collocation is technically infeasible. "Economic infeasibility" for purposes of this section shall mean that the cost of collocation is not a reasonable business decision from an economic standpoint when all factors are considered. (iii) If the tower is designed to accommodate one or more additional carriers or capacity for the location of telecommunications facilities other than that of the applicant and, if so, the application shall designate the nature, quality, and location of the collocation that will be accommodated. (iv) An affidavit submitted with written technical evidence from a radio frequency engineer that the proposed tower or telecommunications facilities cannot be installed or collocated on another person's tower or usable antenna support structure located within the search area and must be located at the proposed site in order to avoid prohibiting or effectively prohibiting the provision of personal wireless service by the applicant. (v) Written technical evidence from a structural engineer that the proposed structure meets the standards set forth in this section 36-466, telecommunication towers, and the applicable requirements of the department of building development services. (vi) A certification submitted with written technical evidence from a qualified agent of the applicant that the proposed facilities meet the standards set forth in this section 36-466, telecommunication towers, and the applicable requirements of the department of building development services. (vii) A certification submitted with written technical evidence from a qualified agent of the applicant that the proposed site of the tower or telecommunications facilities does not pose a risk of explosion, fire, or other danger due to its proximity to volatile, flammable, explosive, or hazardous materials such as LP gas, propane, gasoline, natural gas, or corrosive or other dangerous chemicals. (viii) Written technical documentation of any Federal Aviation Administration (FAA) approvals and lighting requirements and, if applicable, documentation of approval or denial of dual mode lighting as provided in this section 36-466, telecommunication towers, and a statement whether an FAA "Determination of No Hazard to Aviation" is required by 47 C.F.R. part 17 of the tower. If such a determination is required, no building permit for the tower shall be issued until a copy of the determination is filed with the city. g. A map of the city and the first half-mile of all bordering communities showing the design of the applicant's entire existing or proposed wireless telecommunications network. Such map shall, at minimum, indicate the exact location of all proposed or existing tower and antenna sites, their dimensions, specifications, and signal area coverage. h. A site plan drawn to scale specifying the location of tower(s), its planned height, guy anchors (if any), transmission building(s), all telecommunications facilities, accessories, parking access plans, landscaping plans (specifying size, spacing and plant material proposed), fences and zoning designation of adjacent land. i. Two alternative camouflaging techniques or stealth designs for the proposed tower and all associated telecommunications facilities if technically feasible and any explanation as to why the use of same would be technically or economically infeasible. j. Color photo simulations showing the proposed site of the tower with a photo-realistic representation of the proposed tower as it would appear viewed from the closest residential property or properties and from adjacent roadways. k. The identity of all adjacent property owners. l. If the proposed tower is sited within Central Springfield, evidence that: (i) Sites outside Central Springfield will not accommodate the proposed tower, considering size, topography and physical features; or (ii) The proposed equipment or its equivalent on a tower outside Central Springfield cannot function effectively or at least in parity with other similar equipment in place or approved by the Springfield City Council. (iii) For the purposes of these restrictions, Central Springfield is defined as the area of Springfield containing the central business district and most of the historically and architecturally significant resources of the city, specifically defined by the south boundary of the railroad right-of-way north of Commercial Street on the north, Glenstone Avenue on the east, Grand Street on the south, and Kansas Expressway on the west. m. A maintenance bond in the amount of ten percent of the cost of construction of the tower to ensure that the tower is maintained in a condition that complies with all applicable building standards and regulations, including, but not limited to, the provisions of said ordinance. n. A bond or irrevocable letter of credit in an amount determined by the city manager to ensure that, should the tower be abandoned pursuant to this section 36-466, telecommunication towers, removal of said tower will be guaranteed. o. An applicant shall only be required to maintain one maintenance bond pursuant to subparagraph m. and one removal bond pursuant to subparagraph n for all of the applicant's towers in the city; provided, however, the applicant must maintain the initial level of such bonds if drawn upon by the city for any reason. p. Proof of general liability insurance for claims for injury or death and property damage in an amount approved by the city, but not less than $300,000.00 per occurrence for personal injury and $300,000.00 per occurrence for property damage with the city listed as an additional insured. q. A statement that the applicant has no outstanding and overdue debt to the city. r. An acknowledgment that, by signing a permit application, the applicant agrees to indemnify and hold harmless the city consistent with indemnification language in the application. s. The tower and/or landowner shall promptly notify the city by certified or registered mail of the sale, transfer, or assignment of any tower or telecommunications facility. Each sublease shall be conditioned upon the sublease obtaining the necessary approvals for the subject facility or site from the city prior to sitting such facility. Within 45 days after a license application for a tower not requiring a conditional use permit or a tower other than a Tier II tower is filed with the director of finance, the director shall approve or deny the application if the director of finance determines that the applicant meets all the requirements of subsection 36-466(8)(b). If the application is for a Tier II tower or a tower requiring a use permit, the license application shall be approved or denied within 14 days of the granting of a Tier II or conditional use permit for said tower. If the application is approved, the director of finance shall issue the license itself after all requirements for the tower are complete. 2. Conditional use permit application. If the zoning district in which the tower is proposed to be located requires a conditional use permit, a conditional use permit application and fee shall be submitted to the director of planning and development in accordance with subsection 36-363(10)(b) of this article. 3. Tier II tower permit application. An application for a Tier II tower shall be reviewed by the city council and approved or denied by ordinance following a publication of notice in the same manner as for a conditional use permit application and a public hearing before council. The application shall include the stealth technology being used, a site plan showing the location of the tower(s) on the premises in relation to existing structures and adjacent residential uses, the landscaping plan, and demonstrate that the granting of a permit will not have any adverse impact on adjacent property uses or functions. No public hearing shall be held before city council until a complete application containing all required information and a $100.00 deposit for costs has been filed. No Tier II permit shall be issued until the costs to the city of review of such permit is paid by the applicant. The city council may grant a Tier II tower application upon the applicant demonstrating to the satisfaction of the city council that: a. The tower is to be located on a premises or parcel where public buildings, facilities or structures, school buildings or facilities, church buildings or a noncommercial, not-for-profit residential neighborhood facilities are located; and b. The tower height will not exceed 60 feet; and c. The stealth design blends into the surrounding area and the structures existing on the premises where the tower is to be located; and d. The site plan minimizes the impact of the presence of the tower on adjacent uses; and e. If there is to be more than one tower on a premises, the presence of more than one tower structure (if more than one is to be built) on the same site or premises is a part of the overall stealth design to be utilized on the premises such as, but not limited to, a series of light standards utilized as tower structures; and f. A request for reduction of the separation requirements of subsection 36-566(7)(c)5 for towers on the same premises is a part of the stealth design to be utilized on said site; and g. A request for reduction of the separation requirements of subsection 36-466(7)(c)5 for towers not located on the same premises is necessary for providing service to an area of the city, the separation requirements constitute a barrier to entry into the market place by the applicant, or will constitute a technical or economic hardship on the applicant; and h. Any light or noise from the tower will not violate light and noise standards of the land development code or other codes of the city; and i. The landscaping plan minimizes the impact of the tower location on the appearance of the premises or site on which the tower is to be located. 4. Building permit application. After a conditional use or tier II tower permit has been approved or if such a permit is not required, a building permit application and fee shall be submitted to the director of building development services. The application shall include sealed plans prepared by an engineer licensed in the State of Missouri for the tower construction and site. The tower site plan included with the building permit application shall show the design for, or present existence of, adequate drainage facilities which have been approved by the director of public works. The applicant shall also provide evidence that the applicant has all required licenses. The application shall also include items a through s listed above under subsection 36-466(8)(b). The application shall also include items (a) through (s) listed above. (c) Applications for wireless facilities on towers. No person shall construct or maintain a wireless facility on a tower without first obtaining a license from the director of finance for such wireless facilities. An application shall include the name and address of the applicant, a statement by a qualified engineer or other professional that the addition of such wireless facilities meets all conditions of the City Code, the location of the tower and the location on the tower itself where the wireless facilities will be located, the location on the site for any supporting equipment and utility for said wireless facility, and the approximate length of time the applicant plans to use the tower to locate its wireless facilities. The fee for this license shall be $50.00 and shall be renewable every five years in accordance with subsection 36-466(8)(g). (d) Inspections. By applying for a conditional use permit, Tier II permit, building permit, or tower license, an applicant grants the city authority to enter onto its property to inspect the tower for the purpose of determining whether it complies with the applicable state law and all other construction standards provided by the City Code and federal law. The city reserves the right to conduct such inspections at any time. (e) Filing requirement. A licensee shall certify in writing that its tower is structurally sound and conforms to the requirements of the applicable state law and all other construction standards set forth by the City Code, federal and state law every five years by filing, by January 1 of every fifth year following the date of the grant of its tower license a sworn statement by the licensee or his representative to that effect. All licensees or owners of towers in existence on the effective date of this section 36-466, telecommunication towers, shall submit a statement by December 15, 1997, and by January 1 every five years thereafter that said tower is free from hazards and that the tower does not pose an imminent threat to the surrounding area or public health and safety. Together with this statement, every licensee shall provide a certificate of liability insurance for no less than $300,000.00 coverage for injury to persons or and an additional $300,000.00 coverage for property as a result of any tower failure or malfunction or defect which lists the city as an additional insured. Licensee shall list city as a party who must be notified should this insurance be canceled or discontinued for any reason 30 days before the expiration of coverage. (f) Discontinuance of use. In the event the licensed use of a tower is discontinued by the licensee, the licensee shall provide written notice to the city of its intent to discontinue use and the date when the use shall be discontinued. (g) License renewal fee. On or by January 1 of every fifth year following the granting of an initial tower or wireless telecommunications facilities license for a new or existing tower or facilities placed on a new or existing tower, each licensee shall submit license renewal fee of $50.00. In no event shall a license be revoked or considered expired for failure to pay the fee unless the licensee has received at least 30 days' written notice of the proposed action. (9) Revocation of license. The city may at any time revoke a tower license for failure to comply with the provisions of this section 36-466, telecommunication towers, or any other city code or state or federal law. To properly revoke a tower license, the city must comply with the procedures set forth below: (a) The director of finance shall provide licensee with written notice of all causes for revocation and the intent to revoke and shall allow licensee 60 days subsequent to receipt of the notice in which to correct the violations or to provide adequate assurance of performance in compliance with said ordinance. Together with the notice required herein, the director of finance shall provide licensee with written findings of fact which are the basis of the revocation. (b) The city shall provide the licensee with the right to a public hearing before the hearing examiner appointed for that purpose by the city manager and mutually agreed to by the parties, which public hearing shall follow the 60-day notice required in subsection 36-466(9)(a). All interested parties shall be allowed an opportunity to be heard at the public hearing and present evidence. (c) After the public hearing, the hearing examiner shall, within 30 days after the public hearing date, issue a written order setting forth his findings of fact and conclusions of law forming the basis for his decision. (d) Upon written determination by the hearing examiner to revoke a license, the licensee may appeal the decision to a court of competent jurisdiction pursuant to Chapter 536, RSMo. The hearing examiner may provide for a supersedes bond in an amount deemed by said examiner to be sufficient to protect the interests of the public, and such third parties whose interests were identified during any hearing on such a request to post a bond, to permit the stay of enforcement of any revocation or enforcement action by the city. (e) Upon satisfactory correction by licensee of the violation upon which said notice was given as determined in the director of finance's sole discretion, the initial notice shall become void. (f) Upon licensee's failure to correct a violation as found by the hearing examiner, the city manager or his designee may issue an order to disconnect utilities to said tower to any utility company providing same unless a supersedeas bond in an amount determined by the hearing examiner under subsection 36-466(9)(d) is provided. As long as said bond is in full force and effect, and an appeal is pending under Chapter 536, RSMo, no order to disconnect utilities shall be made. Said order shall not be issued prior to 30 days from the date of the hearing examiner's written determination. Said order shall be served upon the chief executive officer thereof, together with the licensee at the last known address, and have attached to it the findings of the hearing examiner. (10) Transfer of license. A tower license may not be sold, transferred, leased, or assigned to any other person, without the consent of the director of finance, such consent not to be unreasonably withheld. (11) Abandonment of tower. (a) In the event the use of any tower has been discontinued for a period of one year, or in the event that a licensee has taken no action within 180 days after the revocation of a tower license pursuant to subsection 36-466(9) to appeal the decision of the hearing examiner or to remedy or correct the violations resulting in the revocation, such tower shall be deemed abandoned. (b) The city shall provide the tower owner three months' notice and an opportunity to be heard before a hearing examiner appointed by the city manager for the purpose and agreeable to the tower owner if he/she may be located, before initiating such action. After such notice has been provided, the city shall have the authority to initiate proceedings to either acquire the tower and any appurtenances attached thereto at the then fair market value, to approve the sale of the tower to a third party or in the alternative, order the demolition of the tower and all appurtenances. (c) The city shall provide the tower owner with the right to a public hearing before the hearing examiner, which public hearing shall follow the three-month notice required in subsection 36-466(11)(b). All interested parties shall be allowed an opportunity to be heard at the public hearing. (d) After a public hearing is held pursuant to subsection 36-466(11)(a)2, the hearing examiner may order the forfeiture to the city or demolition of the tower. The city may draw upon any maintenance bond as provided in subsection 36-466(8)(b)1.n. or performance bond or letter of credit filed pursuant to subsection 36-466(14) or may otherwise require licensee to pay for all expenses necessary to acquire or demolish the tower. The tower owner may stay such a draw or enforcement of an order of abandonment if he/she posts a supersedeas bond in an amount set by the hearing examiner sufficient to protect the interests of the public. However, in no event shall the removal of a tower which is determined to create a danger to the public or adjacent property be stayed due to the filing of such a bond. (12) Variances and special exceptions. Any request to deviate from any of the requirements of this section shall require either a variance approval in conformance with the procedures set forth in this article or the granting of a special exception under subsection 36-466(7)(c)4. (13) Location of towers on city-owned property. The city manager or his designee may authorize any person to locate a tower, antenna support structure or telecommunications facilities on publicly owned property, subject to the application process set forth in subsection 36-466(8), and subject to the terms and conditions of any lease agreement executed between the city and such person, provided no tower shall be permitted on public right-of-way. (14) Miscellaneous. (a) Dangerous structures. All towers within the city limits of Springfield, Missouri shall be subject to the procedure set forth in chapter 26, article III of the Springfield City Code. Should the city have to take action under said code provision to remove a dangerous structure or abate a nuisance or health hazard, then a tax bill may be assessed in the same manner as for a building that is demolished or for the abatement of a nuisance. In addition, the city may draw upon any bond or letter of credit on file with the city for payment of the costs of such abatement or removal. (b) Non-waiver. Nothing in this section shall preclude the city from exercising any right or remedy it may have in law or equity to enforce the terms and conditions of this section. (15) Enforcement and reservation of rights. (a) The provisions of this section 36-466, telecommunication towers, shall be enforced against all owners as operators of towers or telecommunications facilities within the city and all owners of land upon which towers or telecommunications facilities are sited within the city. The city shall have the right to withhold any approvals with respect to any application by any such party in the event that it shall find that the party is not in compliance with the provision of this section 36-466, telecommunication towers, until such noncompliance has been cured. (b) The city reserves the right to impose any other reasonable conditions it determines are necessary for the proper placement, construction, or modification of towers or telecommunications facilities, and to impose any other reasonable conditions on the issuance of a permit or conditional use permit issued by the city for placement, construction, or modification of a tower or telecommunications facilities.
(Zoning Ord., § 5-2600; G.O. 4740, 9-2-97; G.O. 5094, 7-9-01; G.O. 6136, § 1(exh. A), 9-8-14)
Ask a question about Springfield law
Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.
