§ 36-493 — Screening
Code of the City of Springfield, Missouri (Supp. No. 23, Update 2: codified through G.O. No. 6973, enacted January 12, 2026) · Springfield, Mo., Land Development Code § 36-493
Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/5bac46ac-6baf-484c-aa22-2a57eb56d813
Sec. 36-493. - Screening.
(1) Used frying oil, trash, and recycling receptacles (figure 28). The following regulations shall apply to all non-single-family development. (a) Used frying oil, trash, and recycling receptacles shall be screened on three sides with a solid, opaque material with a minimum height of six feet and a maximum height of eight feet. (b) Materials used for screening shall complement the exterior building cladding materials of the primary building. (c) Materials and elevations for enclosures that are attached to buildings shall be designed to be integrated into the primary building. (d) If enclosures are to be attached to buildings, they shall comply with applicable fire and building codes. (e) Shrubs shall be installed every three feet along the exterior of the enclosure, with the exception of enclosure openings, to provide a softening effect. (f) Enclosure openings shall be gated with an opaque material. (g) Enclosure openings shall be kept closed at all times except for when the receptacle is being accessed. (h) Property owners shall be responsible for ensuring that used frying oil, trash, and recycling receptacles be placed in the enclosure at all times other than when it is being accessed. (i) Access drives shall be constructed of materials and to a thickness which accommodates truck loading. Year-round access to the enclosure area for service trucks shall be maintained by the property owner or tenant. (j) Enclosures shall be of an adequate size to accommodate expected containers. The enclosure shall be designed to be expandable to accommodate future additional containers. (k) Enclosure structures shall be designed to protect the walls from damage by containers. Such protection may be provided by the use of barrier curbing, reinforced masonry walls, or other similar means. (l) Used frying oil, trash, and recycling receptacle enclosures shall not occupy areas used for required parking spaces. [image omitted; see the official code] Figure 28: Used Frying Oil, Trash, and Recycling Receptacle Screening (2) Ground/wall-mounted mechanical units (figure 29). The following regulations shall apply to all ground/wall-mounted mechanical units, including, but not limited to, generators, air-conditioning condensers, heat pumps, ventilation units, computer cooling equipment, etc., and any related utility structures and equipment. Tanks and/or silos related to a brewery, winery, distillery are exempt from these requirements. (a) Locating mechanical units within the primary building is strongly encouraged in order to minimize exterior visual impacts. Ground-mounted mechanical units are prohibited within the front yard, regardless of whether screening is provided. (b) Ground/wall-mounted mechanical units that are visible from any public right-of-way or adjacent residential property shall be screened from public view. (c) Materials used for screening shall be designed and established so that the area or element being screened is no more than 20 percent visible through the screen. (d) Chain-link fence or slats in chain-link fence shall not be used to meet this requirement. [image omitted; see the official code] Figure 29: Ground/Wall-Mounted Mechanical Unit Screening (3) Roof-mounted mechanical units (figure 30). The following regulations shall apply to all roof mounted mechanical units, including, but not limited to, air-conditioning condensers, heat pumps, ventilation units, computer cooling equipment, etc., and any related utility structures and equipment which service multifamily, nonresidential, or mixed-use developments. (a) Locating mechanical units within the primary building is strongly encouraged in order to minimize exterior visual impacts. (b) Roof mounted mechanical units that are visible from any public right-of-way or adjacent residential property shall be completely screened from public view. (c) Materials used for screening shall be architecturally integrated with the building and shall be continuous and permanent. (d) Screening shall be required when new equipment is installed and shall be provided around both new and existing roof mounted mechanical units in order to provide visual continuity. Normal maintenance of roof mounted mechanical units shall not mandate the screening requirements. (e) Additional screening may be required due to topographic differences in the adjoining properties. [image omitted; see the official code] Figure 30: Roof-Mounted Mechanical Unit Screening
(G.O. 6661, § 1(Exh. B), 6-28-21; G.O. 6684, § 1(Exh. B), 9-20-21)
Ask a question about Springfield law
Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.
