Sec. 36-612. - Deletions, modifications, amendments, and additions.

The National Fire Protection Association ("NFPA") 70, National Electrical Code, 2017 (hereinafter referred to as the "NEC"), as adopted, is hereby amended as follows: Section 90.4 Enforcement is repealed in its entirety and replaced with: Section 90.4 Enforcement. It shall be unlawful for any person to install, or permit the installation of, any electrical wiring, equipment, or apparatus within the corporate limits of the City of Springfield, unless the same shall be installed to conform with the standards and provisions of the 2017 NEC, the latest approved edition of the Electrical Service Standards of City Utilities of Springfield, and all other applicable City codes and ordinances. In the event of a conflict between these documents the most stringent or restrictive shall govern, or an administrative interpretation may be made by the Director of Building Development Services to resolve such conflicts. Article 100 Definitions Service Repair. The repair or replacement of a device or element of the service with a new device or element of the service, provided the repair or replacement material is of the same size or ampacity as the original. Service Upgrade. Any service work that cannot be defined as a service repair. Article 110.24 Available Fault Current (B) Modifications: Exceptions: 1. The field-marking requirements in 110.24(A) and 110.24(B) shall not be required in industrial installations where conditions of maintenance and supervision ensure that only qualified persons service the equipment. 2. Field-marking requirements and calculations shall not be required on single-phase aerial or underground electrical installations when the service ampacity does not exceed 200 amps. 210.8 Ground-Fault Circuit-Interrupter Protection for Personnel (A) Dwelling Units. All 125-volt, single-phase, 15- or 20-ampere receptacles installed in locations specified in 210.8(A)(1) through (10) shall have ground-fault circuit-interrupter protection for personnel. (2) Garages and accessory buildings that have a floor located at or below grade level and are: a. not intended as habitable rooms; and, b. limited to storage areas, work areas, and areas of similar use Exception to (2): A single receptacle installed solely for electrical supply of a garage door opener. 210.12 Arc-Fault Circuit-Interrupter Protection (A) Dwelling Units. All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets or devices installed in dwelling unit bedrooms, shall be protected by any of the means described in 210.12(A)(1) through (6). 210.52 Dwelling Unit Receptacle Outlets. (G) Basements, Garages, and Accessory Buildings. (3) Basements. In each separate, unfinished portion of a basement, framed, interior walls for separate rooms constitute finished areas and, therefore, must have branch circuits as required by Article 210, and any required smoke detectors. All wiring must be protected from physical damage by the wall framing or the wall must be covered with sheetrock applied to at least one side of the wall. 230.11. Residential service upgrades and repairs. (A) In all structures used for residential purposes, a service upgrade or modification must include: (1) GFI receptacles in kitchen(s) and bathroom(s), if outlets are in existence at the time of the service upgrade; (2) Approved hard-wired, dual-powered, interconnected smoke alarms installed and located per the adopted building code; (3) A minimum of two (2) 20 amp grounded small appliance branch circuits in kitchens; (4) Carbon monoxide detectors installed according to R315.1 where the structure has an attached garage or fuel-fired appliances; and, (5) Corrections to all apparent hazards. (B) Damage repair. If a fire or other similar incident damages any part of the electrical system within a residential structure, the system, in addition to all damaged systems, must be completely repaired and: (1) All apparent hazards within the structure must be corrected. (2) Hard-wired, dual-powered, interconnected smoke detectors and carbon-monoxide detectors must be installed and located per the adopted building codes. (3) A total or partial upgrade of the electrical system may be required if, in the opinion of an electrical expert in the Department of Building Development Services, the condition of the existing electrical system constitutes a potential threat to the safety and welfare of current or future occupants. 230.70 General. (A) Location. (1) Readily Accessible Location. The service disconnecting means shall be installed at a readily accessible location either outside of a building or structure or inside nearest the point of entrance to the service conductors. The maximum length of conduit between the meter back and service disconnect shall not exceed 36 inches, unless otherwise authorized by the Department of Building Development Services. 230.72 Grouping of Disconnects. (A) General. The two to six disconnects as permitted in 230.71 shall be grouped. The term "grouped" as used in this sub-article is defined as being within two feet of each other, on the same wall, with no intervening obstructions exceeding eight inches in depth from the wall surface, unless otherwise authorized by the Department of Building Development Services prior to installation. Each disconnect shall be marked to indicate the load served. 406.2 Definitions. Child Care Facility. A building or structure, or portion thereof, for educational, supervisory, or personal-care services for children 7 years old or less. 406.12 Tamper-Resistant Receptacles. All 15- and·20-ampere, 125- and 250-volt nonlocking-type receptacles in the areas specified in 406.12(1) through (3) shall be listed tamper-resistant receptacles. (1) Dwelling units in all areas specified in 210.52 as amended and 550.13. (2) Child care facilities as amended. (3) Preschools and elementary education facilities. Exception to (1), (2), and (3): Receptacles in the following locations shall not be required to be tamper resistant: (1) Receptacles located more than 1.7 m (5½ft) above the floor (2) Receptacles that are part of a luminaire or appliance (3) A single receptacle or a duplex receptacle for two appliances located within the dedicated space for each appliance that, in normal use, is not easily moved from one place to another and that is cord-an-plug-connected in accordance with 400.10(A)(6),. (A)(7); or (A)(8). (4) Nongrounding receptacles used for replacements as permitted in 404.4(D)(2)(a).

(Gen. Ord. 6556, § 1, 11-18-19)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.