Sec. 36-622. - Deletions, modifications, amendments and additions.

The 2018 International Plumbing Code as adopted is hereby amended and changed as follows: (a) Chapter 1 is repealed in its entirety because code enforcement is covered in Springfield City Code Chapter 36, Land Development Code, Article I, Administration and Enforcement of Codes and Article X, Uniform Enforcement Procedures. (b) Because Chapter 1 is repealed in its entirety, any cross references to Chapter 1 in subsequent chapters are replaced by the provisions in Article I that correspond, in content, to such cross references. (c) All adopted chapters and appendices include all errata hereafter published by the International Code Council after the date of the first printing of the 2018 International Plumbing Code. [(d)] [Amendments, additions and deletions.] 305.4.1 Sewer depth. Building sewers that connect to private-sewage-disposal systems shall be installed a minimum of 18 inches below finished grade at the point of septic-tank connection. Building sewers shall be installed not less than 12 inches below grade. 312.1 Required tests. The permit holder shall make the applicable tests prescribed in Sections 312.2 through 312.10 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the plumbing work is ready for tests. The code official, or the code official's duly authorized representative, may witness or require verification of these tests. The equipment, material, power, and labor necessary for the inspection and test shall be furnished by the permit holder and he or she shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. Plumbing-system piping shall be tested with either water or, for piping systems other than plastic, by air. After the plumbing fixtures have been set and their traps filled with water, the entire drainage system shall be submitted to final tests. The code official shall require the removal of any cleanouts, if necessary, to ascertain whether the pressure has reached all parts of the system. 403.2 Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. Exceptions: 1. Except for mercantile uses, occupancies which do not serve food or beverages to be consumed within the structure or tenant space, do not require separate facilities when the total occupant load, including both employees and customers, does not exceed 49. 410.4 Substitution. Exception: In all use groups except Use Group A, where the occupant load is less than 49, a bottled water dispenser or water cooler with a minimum 2-gallon capacity may be substituted for the required drinking fountain. Section 504.7 Required pan Exceptions: 1. A pan will not be required if the floor is concrete and a floor drain is adjacent to the device or the floor is a slab-on-grade, concrete floor. 2. A pan will not be required on a water heater changeout if the pre-existing conditions did not contain a pan. 604.8 Water pressure-reducing valve or regulator. An approved water-pressure-reducing valve conforming to ASSE 1003 with strainer shall be installed to reduce the pressure in the building water distribution piping to 80 psi (552 kPa) static or less. 606.3 Access to valves. Ready access shall be provided to all required full-open valves and shutoff valves. 608.1 General. A potable water supply system shall be designed, installed and maintained in such a manner so as to prevent contamination from nonpotable liquids, solids or gases being introduced into the potable and public water supply through cross connections or any other piping connections to the system. Backflow preventer applications shall conform to Table 608.1, except as specifically stated in Sections 608.2 through 608.17.10, and Missouri Department of Natural Resources regulations for backflow prevention in effect at the time of installation; where requirements differ the requirement that provides the highest level of protection shall govern. Installation of a backflow preventer is required as a condition for new systems not governed by the residential code and for permitted modifications to an existing system not governed by the residential code where more than four drainage fixture units, as defined in Table 709.1, are installed; the drainage fixture unit valve for a pot sink or three compartment sink shall be defined as three fixture units. This backflow preventer shall be installed as close as possible to the point where the potable water service enters the building or as approved by the water purveyor. No branch lines or taps will be allowed between the water meter and the backflow preventer. Backflow preventers shall be tested and tagged prior to final plumbing inspection. 608.17.4 Exceptions: Delete subsection 2. 608.17.4.2 Location. All required automatic fire sprinkler and standpipe system backflow preventers shall be located in accordance with the requirements of the water purveyor. Location of backflow preventers shall be such that ready access for service and testing is achieved. Section 608.18 Protection of individual water supplies. An individual water supply shall be located and constructed so as to be safeguarded against contamination in accordance with standards established by the Springfield-Greene County Health Department, the water purveyor, and/or the Missouri Department of Natural Resources, for all site requirements related to protection of individual, water-supply systems. The more restrictive provisions specified for health, safety, and welfare shall apply whenever a conflict exists. Subsections 608.18.1 through 608.18.8 are repealed in their entirety. 802.1.7 Food utensils, dishes, pots-and-pans sinks. Sinks, in other than dwelling units, used for the washing, rinsing, or sanitizing of utensils, dishes, pots, or pans; or, service ware, used in the preparation, serving, or eating of food, shall discharge indirectly through an air gap or an air break to the drainage system. The drainage system includes the grease interceptor. 903.1 Roof extension. Open vent pipes that extend through a roof shall be terminated not less than 12 inches above the roof. Where a roof is to be used for assembly or as a promenade, observation deck, sunbathing deck, or similar purposes, open vent pipes shall terminate not less than 7 feet (2134 mm) above the roof. 918.3 Where permitted. Individual, branch, and circuit vents shall be permitted to terminate with a connection to an individual or branch-type-air-admittance valve in accordance with Section 918.3.1 only with approval from the code official or the code official's duly authorized representative, prior to design or installation. Stack vents and vent stacks shall be permitted to terminate to stack-type-air-admittance valves in accordance with Section 918.3.2 only with approval from the code official or the code official's duly authorized representative prior to design or installation. The use of air-admittance valves shall be permitted only in the remodel of existing buildings and shall not be permitted in new structures and building additions, except for island fixtures, unless otherwise approved by the code official or the code official's duly authorized representative, prior to design or installation. Requests for approval shall be submitted separately in writing. 1003.3 Grease interceptors. Grease interceptors shall comply with the requirements of Sections 1003.3.1 through 1003.3.8 and the requirements and guidelines of the City of Springfield Fats, Oils, and Grease ("FOG") Management Plan, based on the anticipated conditions of use, and shall be subject to the approval of Clean Water Services. 1003.3.1 Grease interceptors and automatic grease removal devices required. A grease interceptor or an automatic, grease-removal device shall be required to receive the drainage from fixtures and equipment with grease-laden waste located in food preparation areas, such as in restaurants, hotel kitchens, hospitals, school kitchens, bars, factory cafeterias, daycare centers, and clubs. Fixtures and equipment shall include: mop sinks; kitchen floor drains and sinks; culinary sinks; hand sinks; pot sinks; prerinse sinks; soup kettles or similar devices; wok stations; floor drains or sinks into which kettles are drained; automatic hood wash units and dishwashers without prerinse sinks. Grease interceptors and automatic grease removal devices shall receive waste only from fixtures and equipment that allow fats, oils, or grease to be discharged. Where the lack of space or other constraints prevent the installation or replacement of a grease interceptor, one or more grease interceptors shall be permitted to be installed on or above the floor and upstream of an existing grease interceptor. 1003.3.2 Food waste disposers restriction. A food-waste disposer shall discharge to a grease interceptor through a solids separator. 1003.3.3 Additives to grease interceptors. Dispensing systems that dispense interceptor performance additives to a grease interceptor shall not be installed. Systems that discharge emulsifiers, chemicals or enzymes to grease interceptors are prohibited. 1003.3.7 Gravity grease interceptors and gravity grease interceptors with fats, oils, and greases disposal systems. The required capacity of gravity grease interceptors and gravity grease interceptors with fats, oils, and greases disposal systems shall be determined by multiplying the peak drain flow into the interceptor in gallons per minute by a retention time of 30 minutes. Gravity grease interceptors shall be designed and tested in accordance with IAPMO/ANSI Z1001. Gravity grease interceptors with fats, oils, and greases disposal systems shall be designed and tested in accordance with ASME A112.14.6 and IAPMO/ANSI Z1001. Gravity grease interceptors and gravity grease interceptors with fats, oils, and greases disposal systems shall be installed in accordance with manu-facturer's instructions. Where manufacturer's instructions are not provided, gravity grease interceptors and gravity grease interceptors with fats, oils, and greases disposal systems shall be installed in compliance with ASME A112.14.6 and IAPMO/ANSI ZIO0I. Concrete grease interceptors are prohibited. 1003.11 Sampling manhole. A sampling manhole shall be installed for all required interceptors in accordance with City of Springfield PublicWorks standard details to monitor the entire building, or to monitor individual tenant space as determined by Clean Water Services. 1202.2 The installation and inspection of all medical gases must be performed by a person who carries a National Inspection Testing & Certification Corporation ("NITC") 6010 Medical Gas Installer Certification or an equivalent certification as approved by the code official. 1202.3 The final inspection of a medical-gas system shall be performed as a special inspection by a person who carries a National Inspection Testing & Certification Corporation ("NITC") 6020 Medical Gas Inspector Certification or an equivalent certification as approved by the code official. This final special inspection must be submitted to the plumbing inspector for approval before the final plumbing inspection can be performed. All language referring to flood-hazard areas is repealed and replaced with: All structures located within a designated flood hazard area shall comply with Chapter 36, Article XVII of the Springfield City Code.

(Gen. Ord. 6557, § 1, 11-18-19)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.