§ 36-632 — Deletions, modifications, amendments, and additions

Code of the City of Springfield, Missouri (Supp. No. 23, Update 2: codified through G.O. No. 6973, enacted January 12, 2026) · Springfield, Mo., Land Development Code § 36-632

Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/44a32dbb-4a2d-49de-81d2-01a45a1eaeef

Sec. 36-632. - Deletions, modifications, amendments, and additions.

The 2018 International Mechanical Code, as adopted, is hereby amended and changed as follows: (a) Chapter 1 is repealed in its entirety because code enforcement is covered in Springfield City Code Chapter 36, Land Development Code, Article I, Administration and Enforcement of Codes and Article X, Uniform Enforcement Procedures. (b) Because Chapter 1 is repealed in its entirety, any cross references to Chapter 1 in subsequent chapters are replaced by the provisions in Article I that correspond, in content, to such cross references. (c) All adopted chapters and appendices include all errata hereafter published by the International Code Council after the date of the first printing of the 2018 International Mechanical Code. [(d)] [Amendments, additions, and deletions.] 301.19 Work materials and equipment in a regulated floodplain. All work materials and equipment performed or installed within a regulated floodplain shall comply with requirements stipulated in Chapter 36, Article XVII Floodplain Management. Equipment and material subject to damage by floodwater within a regulated floodplain shall be elevated not less than two feet above the base flood elevation. All other provisions in this code that refer to work, materials or equipment in a floodplain are repealed and shall be disregarded. 304.11 Guards Exception: Guards are not required on small, walk in-coolers or freezers that are: 1. factory-built; 2. assembled on site; 3. used only by employees; 4. not continuously occupied; and, 5. no greater than 500 square feet in size. 307.2.1 Condensate disposal. Condensate from all cooling coils and evaporators shall be conveyed from the drain-pan outlet to an approved place of disposal. Such piping shall maintain a minimum horizontal slope in the direction of discharge of not less than one-eighth unit vertical in 12 units horizontal (1 percent slope). Condensate shall not discharge into a street, alley, crawl space, or other areas to cause a nuisance. 502.14 Motor vehicle operation. Exception: 4. If it can be shown, subject to the approval of the code official having jurisdiction, that the area of motor vehicle operation in an existing building was previously used as a motor vehicle operation area, a properly listed and labeled exhaust hose not greater than eight (8) feet in length may be used, provided it is connected to the vehicle while in operation and securely attached to a permanent opening through the exterior surface of the building. 506.3.2.5 Grease duct test. Prior to the use or concealment of any portion of a grease-duct system, a leakage test shall be performed. Ducts shall be considered to be concealed where installed in shafts or covered by coating or wraps that prevent the ductwork from being visually inspected on all sides. The permit holder shall be responsible to provide the necessary equipment and perform the grease-duct-leakage test. The grease duct shall be tested by drawing a vacuum on or pressurizing the installed, in place, grease duct to a minimum of 4 inches water column (995 pa, 0.144 psi). The test shall be witnessed by the code official or the code official's duly authorized agent. The grease duct will pass inspection if the pressure or vacuum applied holds for 15 minutes with zero leakage. Measurement shall me made with a digital manometer or pressure gauge with an accuracy of 0.5 percent. The measurement device shall be connected to the test cover of the hood and duct connection and shall be readily accessible for reading. 509.2 Domestic Uses. Cooking appliances required by section 505.6 to have a domestic, cooking-exhaust system shall be provided with a UL 300 A listed fire suppression system.

(Gen. Ord. 6558, § 1, 11-18-19)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.