§ 29-159 — National categorical pretreatment standards; local limits
Code of Ordinances of the City of St. Joseph, Missouri (Codified through Ordinance No. 3140, enacted February 2, 2026. (Supp. No. 8)) · St. Joseph Code of Ordinances § 29-159
Corpus is an independent public-information project, not the official City of St. Joseph website. Stable reference: corpuslaw.us/code/69958aff-70c2-42b9-9882-32ee91ee23ee
Sec. 29-159. - National categorical pretreatment standards; local limits.
(a) Adopted. The categorical pretreatment standards found at 40 CFR Chapter I, Subchapter N, Parts 405—471 are hereby incorporated, as though fully set out herein. (b) Limits. All users shall comply with flow limits and pollutant discharge limits stated in wastewater discharge permits issued to them. (c) Mass and concentration conversion—When allowed. The city may convert the limits of the categorical pretreatment standards at 40 CFR Parts 414, 419, and 455 from mass limits to concentration limits, or from concentration limits to mass limits, for purposes of calculating limitations applicable to individual users only when, in converting such limits, the city uses the concentrations listed in the applicable subparts of 40 CFR Parts 414, 419, and 455 and documents that dilution is not being substituted for treatment. (d) Mass and concentration conversion—Method. Pollutant discharge limits in categorical pretreatment standards may be expressed either as concentration or mass limits. Where concentration limits are specified, the city may, in its discretion, provide equivalent mass limits and where mass limits are specified, the city may, in its discretion, provide equivalent concentration limits. When such equivalent limits are provided, local, state or federal authorities responsible for enforcement may use either concentration or mass limits as a basis for enforcement. Limits in the categorical pretreatment standards shall apply to the effluent of the process regulated by the standard, or as otherwise specified by the standard. (1) Calculation method—Concentration-to-mass. Equivalent mass limitations that are calculated based upon concentration limits shall be calculated by multiplying the applicable mass limit by the individual user's average rate of production. This average rate of production shall be based upon a reasonable measure of the user's actual long-term daily production (such as the average daily production during a representative year) rather than the user's designed production capacity. For new sources provided by a user, actual production shall be estimated using projected production. (2) Calculation method—Mass-to-concentration. Equivalent concentration limitations that are calculated based upon mass limitations shall be calculated by dividing the applicable mass limitations by the individual user's average daily flow rate of regulated process wastewater. This average daily flow rate shall be based upon a reasonable measure of the user's actual long-term average flow rate (such as the average daily flow rate during the representative year). (e) User-requested conversions. When categorical pretreatment standard limits are expressed only in terms of pollutant concentrations, a user may request that the city convert the limits to equivalent mass limits. The determination to convert concentration limits to mass limits is within the discretion of the city; however, the city may establish equivalent mass limits upon the user's request only if the user: (1) Employs, or demonstrate that it will employ, water conservation methods and technologies that substantially reduce or otherwise limit water use during the term of any applicable control mechanism; (2) Currently uses control and treatment technologies adequate to achieve compliance with the applicable categorical pretreatment standard, and has not used dilution as a substitute for treatment; (3) Provides sufficient information to establish the user's actual average daily flow rate for all wastestreams, based on data from a continuous effluent flow monitoring device, as well as the facility's long-term average production rate. Both the actual average daily flow rate and long-term average production rate must be representative of then-current operating conditions; (4) Not have daily flow rates, production levels, or pollutant levels that vary so significantly that equivalent mass limits are not appropriate to control the discharge; and (5) Have consistently complied with all applicable categorical pretreatment standards during the period prior to the user's request for equivalent mass limits. (f) Equivalent mass limit requirements. A user subject to equivalent mass limits which have been converted from concentration limits must: (1) Maintain and effectively operate control and treatment technologies adequate to achieve compliance with the equivalent mass limits; (2) Record the facility's flow rates through the use of a continuous effluent flow monitoring device; (3) Record the facility's production rates and notify the city whenever production rates are expected to vary by more than 20 percent from baseline production rates. Upon notification of a revised production rate, the city may reassess the equivalent mass limit and revise the limit as necessary to reflect changed conditions at the facility; and (4) Continue to employ the same or comparable water conservation methods and technologies so long as it discharges under an equivalent mass limit. (g) Conversion exceptions. Notwithstanding any other provision of this section, limits for pollutants which cannot appropriately be expressed as mass, including, but not limited to pH, temperature, and radiation must be limited in terms of concentration and may not be limited in terms of mass. (h) Compliance with conversions. Conversions of mass and concentration are deemed pretreatment standards pursuant to this Code. The city will document how conversions were derived. Once incorporated into a user's permit or other control mechanism, the user must comply with the equivalent limitations in lieu of the promulgated categorical standards from which the equivalent limitations were derived. (i) Maximum discharge. When categorical pretreatment standards specify one limit for calculating maximum daily discharge limitations and a second limit for calculating maximum monthly average or four-day average limitations, the same production or flow figure shall be used in calculating both the daily discharge and the average. (j) Significant changes. Any user operating under a control mechanism incorporating equivalent mass or concentration limits calculated from a production-based standard shall notify the city within two business days after the user has a reasonable basis to know that the production level will significantly change within the next calendar month. Any user not notifying the city of such anticipated change will be required to meet the mass or concentration limits in its control mechanism that were based on the original estimate of the long term average production rate. (k) Variances. A user may obtain a variance from a categorical pretreatment standard if the user can prove, pursuant to the procedural and substantive provisions in 40 CFR 403.13, that factors relating to its discharge are fundamentally different from the factors considered by EPA when developing the categorical pretreatment standard. (l) Net gross adjustments. A user may obtain a net gross adjustment to a categorical standard in accordance with 40 CFR 403.15.
(Gen. Ord. No. 1049, § 1(23-77(h)), 12-7-92; G.O. 1742, 1-10-00; G.O. 2735, 6-23-14)
Ask a question about St. Joseph law
Corpus searches the St. Joseph sections it holds and shows the ones that match, with their citations. Free, no sign-in.