§ 7-34 — Amendments and changes to the residential code

Code of Ordinances of the City of St. Joseph, Missouri (Codified through Ordinance No. 3140, enacted February 2, 2026. (Supp. No. 8)) · St. Joseph Code of Ordinances § 7-34

Corpus is an independent public-information project, not the official City of St. Joseph website. Stable reference: corpuslaw.us/code/f67ad844-3214-4c33-9c9a-ffbf38974518

Sec. 7-34. - Amendments and changes to the residential code.

The International Residential Code (IRC), as adopted in Section 7-32, is changed by the following insertions, additions and deletions: (1) General: All references to "board of appeals" shall be replaced by "trades board of appeals." (2) Section R101 General. The IRC, Section R101, General, is amended by deleting Subsection R101.1 and substituting the following: R101.1 Title. These provisions shall be known as the residential code of one- and two-family dwellings of the City of St. Joseph, Missouri, and shall be cited as such and will be referred herein as "this code". (3) Section R105.Permits. The IRC, Section R105, Permits is amended by deleting Subsection R105.2. (4) Section R106 Construction Documents. The IRC, Section R106, Construction Documents, is amended by deleting Subsection R106.1 and substituting the following: R106.1 Submittal documents. Construction documents, special inspection and structural observation programs and other data shall be submitted in one or more set with each application for a permit. The construction documents shall be prepared by a Missouri registered design professional where required by the State of Missouri. Where special conditions exist, the building official is authorized to require additional construction documents to be prepared by a Missouri registered design professional. Exception: The building official is authorized to waive the submission of construction documents and other data not required to be prepared by a Missouri registered design professional if it is found that the nature of the work applied for is such that reviewing of construction documents is not necessary to obtain compliance with this code. (5) Section R108 Fees. The IRC, Section R108, Fees, is amended by deleting Subsections R108.2 and R108.5 and substituting the following: R108.2 Schedule of permit fees. On buildings, structures, electrical, gas, mechanical and plumbing systems or alterations requiring a permit, a fee for each permit shall be paid in accordance with Chapter 7, Article VIII, schedule of fees, Sections 7-400 through 7-404 of the City of St. Joseph's Code of Ordinances. R108.5 Refunds. Fees collected under the above sections shall be refunded where such work has not been commenced prior to the abandonment thereof, and the permit has not expired by time limitations. However, if any such work has been commenced, and then abandoned, or where a permit has expired after work has commenced or where a permit has been revoked, no refund of any building fee shall be made. (6) Section R108 Fees. The IRC, Section R108, Fees, is amended by adding the following: R108.6 Work commencing before permit issuance. Any person who commences any work on a building, structure, electrical, gas, mechanical or plumbing system before first obtaining the necessary permits may be charged double the normal required permit fee. The payment of such double fee shall not relieve any persons from fully complying with the requirements of this code in the execution of the work nor from any other penalties presented herein. (7) Section R112 Board of Appeals. The IRC, Section R112, Board of Appeals, is amended by deleting Section R112.1 and substituting the following: R112.1 Appeals to the trades board of appeals. Any person aggrieved by a decision of the chief building official's or inspector's interpretation of the residential code, may appeal such decision to the trades board of appeals using the process set forth in Chapter 2, Article V, Section 2-790 "Appeals" of the Code of Ordinances. (8) Section R113 Violations. The IRC, Section R113, Violations, is amended by deleting Subsection R113.4 and substituting the following: R113.4 Violation Penalties. Any person who shall violate a provision of the 2018 IRC, or shall fail to comply with any of the requirements thereof or who shall erect, construct, alter or repair a building or structure in violation of an approved plan or directive of the building official, or a permit or certificate issued under the provisions of the basic code, may be guilty of a misdemeanor, punishable by a fine under Section 7-6 of the Code of Ordinances of the City of St. Joseph, Missouri. (9) Section R114 Stop Work Order. The IRC, Section R114, Stop Work Order, is amended by deleting Subsection R114.2 and substituting the following: R114.2 Unlawful continuance. Any person who shall continue any work in or about the building after having been served with a stop work order, verbally or in writing, except such work as that person is directed to perform to remove a violation or unsafe condition, may be issued a citation and, if found guilty, fined in accordance with Section 7-6 of the Code of Ordinances of the City of St. Joseph, Missouri. (10) Section R301 Design Criteria. The IRC, Section R301, Design Criteria, is amended by inserting the following into Table R301.2(1): Wind speed = 90 mph; Seismic design category = B; Weathering = Severe; Frost Line Depth = 36 inches; Termite = Moderate to Heavy; Decay = slight to moderate; Winter Design Temp = 2 degrees; Flood hazard = September 19, 1984. (11) Section R313 Automatic Fire Sprinkler Systems. The IRC, Section R313, Automatic Fire Sprinkler Systems, is amended by deleting Section R313 in its entirety. (12) Section E3902 Ground-Fault and Arc-Fault Circuit-Interrupter Protection. The IRC, Section E3902, Ground-Fault and Arc-Fault Circuit-Interrupter Protection, is amended by deleting Subsection E3902.2 and substituting the following: E3902.2 Garage and accessory building receptacles. All 125-volt, single-phase, 15- or 20-ampere receptacles installed in garages and grade-level portions of unfinished accessory buildings used for storage or work areas shall have ground-fault circuit-interrupter protection for personnel. Receptacles supplying garage door openers, sump pumps and freezers are not required to have ground-fault circuit-interrupter (GFCI). The freezer outlet shall be identified. (13) Section E3902 Ground-Fault and Arc-Fault Circuit-Interrupter Protection. The IRC, Section E3902, Ground-Fault and Arc-Fault Circuit-Interrupter Protection, is amended by deleting Subsection E3902.5 and substituting the following: E3902.5. Unfinished basement receptacles. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in unfinished basements shall have ground-fault circuit-interrupter protection for personnel. For purposes of this section, unfinished basements are defined as portions or areas of the basement not intended as habitable rooms and limited to storage areas, work areas, and the like. Receptacles supplying sump pumps and freezers are not required to have ground-fault circuit-interrupter (GFCI). The freezer outlet shall be identified. Exceptions: A receptacle supplying only a permanently installed fire alarm or burglar alarm system. (14) Section E3902 Ground-Fault and Arc-Fault Circuit-Interrupter Protection. The IRC, Section E3902, Ground-Fault and Arc-Fault Circuit-Interrupter Protection, is amended by deleting Subsection E3902.12 and substituting the following: E3902.12 Arc-fault circuit-interrupter protection. All branch circuits that supply 120-volt, single-phase, 15- and 20-ampere outlets installed in bedrooms shall be protected by a combination type arc-fault circuit interrupter installed to provide protection of the branch circuit. Exceptions: 1. Where an outlet branch-circuit type AFCI is installed at the first outlet to provide protection for the remaining portion of the branch circuit, the portion of the branch circuit between the branch-circuit overcurrent device and the first outlet shall be installed with metal outlet and junction boxes and RMC, IMC, EMT, type MC, or steel armored type AC cables meeting the requirements of Section E3908.8. 2. Where an outlet branch-circuit type AFCI is installed at the first outlet to provide protection for the remaining portion of the branch circuit, the portion of the branch circuit between the branch-circuit overcurrent device and the first outlet shall be installed with metal or nonmetallic conduit or tubing that is encased in not less than 2 inches (51 mm) of concrete. 3. AFCI protection is not required for an individual branch circuit supplying only a fire alarm system where the branch circuit is wired with metal outlet and junction boxes and RMC, IMC, EMT or steel-sheathed armored cable Type AC, or Type MC meeting the requirements of Section E3908.8. (15) Section E4002 Receptacles. The IRC, Section E4002, Receptacles, is amended by deleting Subsection E4002.14 in its entirety. (16) The IRC, is amended by deleting Chapters 12 through 33 in their entirety and Sections G2413, G2414, G2415, G2416, G2417, G2418, G2419, G2420, G2421, G2422, G2423 and G2424 in their entireties. (17) The IRC is amended by adding a new chapter to be known as Chapter 45, entitled "Housing Numbering," to be read as follows: Chapter 45. Housing Numbering. Section R4501 Housing numbering. The city planner shall assign all numbers and addresses to new and existing buildings and keep a record of the same according to streets. The code official shall furnish all owners and builders of buildings with said building numbers. Section R4502 Duty of Contractor. (a) The contractor or builder in charge of the greater part of the work of erecting or moving any building in the city shall report the location thereof to the code official and procure a certificate of the number to be placed thereon, and shall cause such number to be placed on the building as soon as practically possible. (b) The contractor in charge of the greater part of the work remodeling, renovating or adding to any building or unit shall cause the number to be placed on the building or unit as soon as practically possible.

(Gen. Ord. No. 1193, § 1(7-2), 7-18-94; G.O. 1866, 1-7-02; G.O. 2225, 5-7-07; G.O. 2260, 10-22-07; G.O. 2660, 12-10-12; G.O. 2674, 3-4-13; G.O. 2865, 7-2-18; G.O. 3123, 2(Exh. A), 3-17-25)

Ask a question about St. Joseph law

Corpus searches the St. Joseph sections it holds and shows the ones that match, with their citations. Free, no sign-in.