§ 11.79.300 — Recirculating system
Revised Code of the City of Saint Louis, 2020, Annotated (Supp. No. 11: codified through Ordinance No. 72042, enacted October 30, 2025) · St. Louis Revised Code § 11.79.300
Corpus is an independent public-information project, not the official City of St. Louis website. Stable reference: corpuslaw.us/code/515de225-ffd3-446c-b7b1-42e5e72dfe4d
11.79.300 - Recirculating system.
A recirculation system consisting of pumps, piping, filters, water conditioning and disinfecting equipment, and other accessory equipment, shall be provided which will clarify and disinfect the swimming pool volume of water in six (6) hours or less, thus providing a minimum turnover of at least four (4) times in twenty four (24) hours when operating at designed maximum head loss. The recirculation system shall operate continuously twenty-four (24) hours a day. A. Rate. The recirculation system shall be capable of clarifying and disinfecting the pool volume of water in six (6) hours or less, thus providing a turnover of at least four (4) times in twenty-four (24) hours. A turnover each four (4) hours, or six (6) times in each twenty-four (24) hour period is recommended. The turnover rate shall be maintained up to and including the time at which the filter needs to be backwashed. Pools built for diving only may be designed for an eight (8) hour turnover rate. B. Hydraulics and Piping System. All piping shall be designed to reduce friction losses to a minimum and to carry the required quantity of water at a maximum velocity not to exceed eight (8) feet per second for pressure, six (6) feet per second for suction and four (4) feet per second for gravity. All piping shall be of non-toxic material resistant to corrosion and able to withstand operating pressures. Flange joints or unions should be inserted at intervals to permit take down and cleaning. A blow-off shall be provided for the collection of samples of recirculated and treated water. All piping and valves should be identified by color code or tag. C. Hair Strainer. The recirculation system shall include a strainer to prevent hair, lint, etc., from reaching the pump and filters. Strainers shall be corrosion-resistant with openings not more than one-eighth (⅛) inch in size and the total area of the openings shall be ten (10) times the area of the inlet pipe. The strainer shall be readily accessible to frequent cleaning. Spare screens or baskets shall be readily available. D. Vacuum System. Equipment should be provided to remove sludge, sediment and other accumulations from the bottom of the pool. A built-in vacuum system is preferred, but portable equipment will be accepted. Vacuum pipes must have a minimum diameter of one and one-half (1½) inches and vacuum hoses one and one-half (1½) inches. A valve or other regulating device should be provided to reduce flow from the pool outlet when the vacuum system is in use. E. Flow Measurement. A rate-of-flow indicator, reading in gallons per minute, shall be installed and located so that the rate of circulation and backwash rate will be indicated. The indicator shall be accurate within ten (10) percent of true flow and installed per manufacturer's instructions. F. Pump Selection. Pumps shall be of adequate capacity to provide the required number of turnovers of pool water as specified in Section 11.79.290. If the pump or suction piping is located above the overflow level of the pool, the pump shall be self priming. The pump or pumps shall be capable of providing flows and pressures adequate for the backwashing of filters. The pump suction header shall be provided with gauges which indicate both pressure and vacuum and a pressure gauge shall be installed on the pump discharge line. These shall be installed on the pump discharge line these shall be installed as near to the pump inlet as possible. The backwash pump must have sufficient capacity to backwash a filter unit at the prescribed rate. A pump curve shall be provided as part of the pump specifications. A separate system must be used for each pool, i.e., diving, swimming, or wading unless adequate provisions are made to assure the minimum prescribed turnover. G. Thermometer. Pools equipped with heaters shall have a fixed thermometer in the recirculation line beyond the heater and another near the outlet of the pool. H. Backwash Water. All wastewater generated from the backwashing of filtration systems shall be discharged as an indirect waste to a sanitary sewer. An air gap of six (6) inch minimum height shall be utilized. Discharge to other than the sanitary sewer may be allowed under extraordinary circumstances.
(1994 C., § 11.79.300; Ord. No. 65567, § 30, 2002.)
Ask a question about St. Louis law
Corpus searches the St. Louis sections it holds and shows the ones that match, with their citations. Free, no sign-in.