§ 25.40.040 — Exits—Size and number—Designation

Revised Code of the City of Saint Louis, 2020, Annotated (Supp. No. 11: codified through Ordinance No. 72042, enacted October 30, 2025) · St. Louis Revised Code § 25.40.040

Corpus is an independent public-information project, not the official City of St. Louis website. Stable reference: corpuslaw.us/code/ec4b2b74-f23e-4380-b4c5-4367e7cb55f4

25.40.040 - Exits—Size and number—Designation.

There shall be at least two exits not less than five feet in width, one located at each end of the auditorium, leading directly to gangplanks connected with the dock, pier or the shore. All exits shall be plainly indicated by letters not less than four inches in height, placed over every doorway or passageway leading to the outside. Each exit shall at all times be kept free from curtains, portieres and similar obstructions, and shall be marked plainly with a red light. Every such boat, barge or vessel shall have an exit from the stage to a passageway not less than four feet wide. This passageway shall lead to an exit from the boat, barge or vessel. There shall be a clear, unobstructed passageway leading from the stage and all dressing rooms to such exit.

(1948 C., Ch. 67, § 30; 1960 C., § 718.040; 1994 C., § 25.40.040.)