For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 2.15 — Accessory buildings or uses shall be subject to the following requirements

Zoning Ordinance, City of Brandon, adopted April 6, 2026 · Brandon Zoning Regulations § 2.15

Corpus is an independent public-information project, not the official City of Brandon website. Stable reference: corpuslaw.us/code/47d6df70-e83e-4e54-b4de-50fbfba2e266

2.15 Accessory buildings or uses shall be subject to the following requirements.

a. No accessory building or use shall be permitted in any required yard, other than a rear yard in all districts except:

i. When located in any RE district, accessory buildings may be permitted in the required side yard.

ii. When located in an R-12 district, accessory buildings, such as detached garages or carports, may be permitted in the required side yard only if the architecture of the accessory building matches the main dwelling and is constructed of like materials, finishes, and colors.

The rear yard is the area between the rear property line and the nearest vertical portion of the main building, and extending the full width of the lot.

b. No accessory building or use shall be erected closer than five feet from another building.

c. The maximum size and dimensional requirements for accessory buildings are specified in table 2.16, accessory building dimensional requirements, below.

| Table 2.16 Accessory Building Dimensional Requirements - Development Standard ■ = Required X= Not Applicable | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Residential - Any RE | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Residential - R-12 | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Residential - R-8 | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Residential - RM-8 | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Residential - RM-4 | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Residential - RH | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Residential - RM | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Commercial - NC | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Commercial - CC | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Commercial - RC | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Employment - I-1 | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Employment - I-2 | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Employment - ORC | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Special - VMU | Table 2.16 Accessory Building Dimensional Requirements - Zoning District - Special - PUD | |----------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------| | Maximum height (feet) | 20 | 20 | 20 | 20 | 20 | 20 | 8 | | | | 20 | | | | 20 | | Sideyard setback (feet) | 10 | 8 | 5 | 5 | 5 | 5 | 10 | | | | 30 | | | | 5 | | Rear yard setback (feet) | 10 | 5 | 5 | 5 | 5 | 5 | 5 | | | | 15 | | | | 5 | | Rear yard when abutting residential district (feet) | - | - | - | - | - | - | - | | | | 50 | | | | | | Maximum size shall not exceed 5% of the area or 750 square feet whichever is greater | X | ■ | ■ | ■ | ■ | ■ | ■ | X | X | X | X | X | X | X | ■ |

![Official zoning table, printed page 9 (PDF page 10)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/3b9868d1d939cc76951b04890dc75d3eeb7378ac0d7cf24853e6c025a996dc4c-zoning-table-10-1.png)

![Official zoning figure, printed page 10 (PDF page 11)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/dde6463e17208e64fe61a8aa3847ea54f98c037309a54388714f2a4969c0258b-zoning-figure-11-1.png)

| Table 2.17 Permitted Setback Area Encroachments - Feature | Table 2.17 Permitted Setback Area Encroachments - Extent and Limitations | |-----------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Open balconies, fire escapes, or stairways | May extend up to five feet into any required setback area | | Bay windows | May extend up to three feet into any required setback area if no more than nine feet wide | | Chimneys or fireplaces | May extend up to three feet into any required setback area | | Moveable awnings | May extend up to three feet into any required setback area | | Roof eaves and overhangs, or marquees | May extend up to three feet into any required setback area | | Sills or entablatures | May extend up to 12 inches into any required setback area | | Uncovered porches, stoops, decks, patios, terraces, or walkways | May extend into or be located in any required setback area if less than 12 inches higher than ground level; may extend up to three feet into any required setback area if more than 12 inches, but less than 30 inches, higher than ground level | | Signs, projecting or freestanding | May extend into or be located in any required setback area in accordance with table 8.7: table of sign dimensions and locations | | Flagpoles | May be located in any required setback area if less than 20 feet high, set back from side and rear lot lines by at least ten feet, and set back from front and corner side lot lines by a distance equal to the flagpole height | | Lighting fixtures | May be located in any required setback area if less than 20 feet high | | Fences or walls | May be located in any setback area, subject to the limitations in table 5.5, fences and walls | | Accessory structures other than those listed above | Subject to the limitations in section 2.15 and in table 2.16 | | Vegetation and landscaping features such as retaining walls, fountains, ponds, and similar landscaping features | May be located in any required setback area |

![Official zoning table, printed page 11 (PDF page 12)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/61113fa67ba6aa6816f0c95cf51421d9cd6117102cf0b1d5e146b4c193573857-zoning-table-12-2.png)

Ask a question about Brandon law

Corpus searches the Brandon sections it holds and shows the ones that match, with their citations. Free, no sign-in.