§ 4.12.10 — Foundations and Anchors
D'Iberville Zoning Ordinance (revised September 16, 2025); partial (City-posted PDF; later amendments unverified) · D'Iberville Zoning Ordinance § 4.12.10
Corpus is an independent public-information project, not the official City of D'Iberville website. Stable reference: corpuslaw.us/code/2b7dfbb8-a757-4357-ab6a-7347530f6a2a
4.12.10. Foundations and Anchors
A. A manufactured home and/or mobile home stand (pad) is required for each manufactured home and/or mobile home lot. Each pad shall be well drained, uniformly graded and compacted as approved by the Building Official. B. Foundations and anchor systems shall be installed according to State Law. Every manufactured home shall be installed in accordance with the manufacturer's “owner’s manual” or at a minimum, the Uniform Standard Code for Factory Manufactured Homes Act and the rules and regulations of the Manufactured Home Division of the Mississippi State Fire Marshall's Office. C. All tie down straps shall be 1.25"x 0.035"galvanized steel conforming to ASTM standard specifications 10- 3953-91. Tie down straps to be Type I, Finish B, Grade 1 steel strapping certified by a registered professional engineer. Strap to have an ultimate load capacity of 4,725 lbs. and an allowable working load of 3,150 lbs minimum. D. Ground anchors shall be cable of resisting a tensile load of 5,000 lbs. and an angle load (45 degrees) of 4000 lbs. minimum per anchor. Anchors shall be installed full depth, below frost line and 12" minimum above water table. Minimum anchor capacity required is as noted and indicated on P.E. Certified Pier and Tie Down details. Anchors should be certified by a professional engineer, architect, or a nationally recognized testing laboratory as to their resistance, based on the maximum angle or diagonal tie and/or vertical tie loading and angle of anchor installation and type of soil in while the anchor is to be installed. Anchoring equipment exposed to weathering shall have a resistance to weather deterioration at least equivalent to that provided by a coating of zinc on steel of not less than 0.30 ounces per square foot of surface coated. E. The frame tie down straps shall be installed on the outermost I-Beam of the home using the spacing shown in the "owner's manual". F. Strap installation to anchors must be in accordance with "owner's manual". G. Tie down straps must be tightened alternately on opposite sides of the home or the home may be pulled off its supports. Stabilizer plates shall be installed to provide added resistance to overturning or sliding forces. H. Where a vertical tie and a diagonal tie are located at the same place, both ties may be connected to a single anchor, provided that the anchor used is capable of carrying both loads simultaneously. I. This aforementioned system is based on the assumption that the home itself is constructed to resist the design load reference above, if not, owner must present to the Building Official a certified professional engineers plans for the anchoring of said manufactured and/or mobile home in accordance with HUD Wind Zone II regulations.
Ask a question about D'Iberville law
Corpus searches the D'Iberville sections it holds and shows the ones that match, with their citations. Free, no sign-in.