For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.11 — Tiered Land Use System and Bonus Provisions

Gautier Unified Development Ordinance (cover updated June 19, 2025); partial · Gautier Unified Development Ordinance § 5.11

Corpus is an independent public-information project, not the official City of Gautier website. Stable reference: corpuslaw.us/code/990d09d4-1921-4351-bca8-2e3684fd1f1c

SECTION 5.11 Tiered Land Use System and Bonus Provisions

A. Purpose and Intent. The intent of the bonus provisions in the tiered land use system is to offer applicants incentives for investing in quality, innovative development that enhances site and building design, enhances compatibility, enhances non-motorized mobility, and provides the opportunities for achieving extraordinary public benefit. The tiered land use system implements the City’s Comprehensive Plan. B. Applicability. This section shall apply to all development within the COR, Corridor Overlay District and zoned one of the following: TCMU, MUMS, MURC, C-1, C-2, C-3, R-2 and R-3. The height, intensity, and density limits of each of the Tiers is set forth within the Table 7 of this Ordinance. C. Establishment of Tiers. The following land use tiers are hereby established in order to designate the maximum height, density and intensity of development. Tier 1. Unless otherwise specified, Tier 1 standards represent the maximum "by- right" building height, density and intensity, which can be achieved by adherence to the standard site development criteria established in this code. Tier 2. Tier 2 standards allows for the attainment of additional building height, density and intensity beyond Tier 1. Tier 3. Tier 3 standards provide for additional building height, density and intensity beyond Tier 2. D. Design Review Requirements. The following design review requirements shall be adhered to when applying for Tier 2 or Tier 3 approval: 1. Applicants seeking Tier 2 height, density and intensity bonuses shall submit a Major Development application, in accordance with the major development review process established in Article IV, requesting Tier 2 approval and must meet the specified supplemental standards specified in subsection F, below. 2. Applicants seeking Tier 3 height, density and intensity bonuses shall meet all of the Tier 2 supplemental standards specified in subsection F, Tier 3 supplemental design analysis, and provide public benefits. E. The height, intensity, and density limits of each of the Tiers are set forth within the Table 7 of this Ordinance. The Planning Director may also grant at his/her discretion the following administrative variances in accordance with Section 4.18.3: 1. 30% of required off-street parking spaces and/or 2. 30% of required setbacks from property lines F. Tier 2 Supplemental Design Standards. The following supplemental standards shall be met in order to qualify for Tier 2 height, intensity and density bonuses: 1. Design criteria. All developments shall meet the following design criteria requirements, in addition to the standards established by Article VIII. 2. Building footprint. Buildings shall be located and designed so as to maximize the "functional open space" on the site. Such functional open space shall take the form of view corridors, outdoor gardens, walking areas, or areas for the congregation of people for special events. Such areas may be an integral part of building features such as entranceways and pedestrian amenities providing pedestrian access through buildings and throughout the site. Additionally, buildings shall be oriented towards the public street frontage and shall be constructed as close to the adjacent right-of-way as possible in order to improve access from the transportation network. A continuous facade line shall be used along a block to provide an accessible and attractive streetscape. It is the intent of this section to have building facades along the length of the adjacent rights-of-way, if applicable, except where vehicular or pedestrian access ways are required or needed. In no case however, shall a building or structure be located so as to block the clear visibility triangle for a vehicular access way from the subject property onto adjacent rights-of- way. 3. Building facade and public art. Facades shall be designed to provide visual interest that will be consistent with the community's character and identity as “Nature’s Playground” through the use of artistic detail. Such detail may include nautical and/or natural elements such as metal fabricated to look like marine knots or natural grasses and reeds. To break up large unadorned walls, sidewalk displays, public art displays, or other such features that provide visual interest shall be used in the design and construction of facades. 4. Roofline design: The use of varied rooflines, through the utilization of parapets and/or sloped roofs, is required. 5. Supplemental setback and buffering requirements from single- family, duplex, or townhome uses. All development located in C-1, C-2, C-3, MURC and TCMU zoning designations that abut single-family, duplex or townhome uses located in zoning designations different from abutting uses shall meet the following supplemental setbacks and buffers requirements: a. Setbacks. Any portion of a building that abuts single-family, duplex or townhome uses shall provide a setback from those uses that is the greater of one (1) foot for every foot in height (e.g. 160- foot tall project will have an 160-foot setback), or the distance required so as not to cast a shadow on such residential uses, as measured to the property line of the residential use, between 9:00 a.m. and 4:00 p.m. central time. The date used in the shadow study shall be the autumnal equinox for the year that the study is performed. The autumnal equinox (the day of the year when night and day are nearly of the same length and the first day of autumn) is typically the date between the summer solstice (longest day of the year and the first day of summer) and the winter solstice (shortest day of the year and the first day of winter). Applicants that prefer to use the shadow option may be required to submit a shadow study to demonstrate that a project provides adequate setbacks. b. Buffers. Minimum supplemental buffers shall be provided by the more intense use or zoning district when abutting single-family, duplex, or townhome uses. i. Areas used or set aside for parking, loading, accessways, or service and utility areas shall not be located within twenty (20) feet of the property line when such property line abuts single-family, duplex or townhome uses. ii. A minimum of six (6) feet and not higher than eight (8) feet tall decorative, opaque, masonry wall shall be located within five (5) feet of the property line along the extent of any parking, loading, accessway, or service and utility area located adjacent to a single-family, duplex or townhome use. iii. Supplemental landscaping shall be provided along the property line within the required ten (10) foot wide landscape buffer. One (1) of the following landscaping designs shall be provided. a. For every ten (10) linear feet of landscape buffer, a minimum of one (1) tree and fifteen (15) shrubs must be planted. The required landscaping may be planted on either side of the required wall. Trees shall be a minimum of fourteen (14) feet in height and have a three and one-half (3.5) inch caliper at the time of planting. Shrubs shall be a minimum of twenty-four (24) inches in height at the time of planting; or b. For every fifty (50) linear feet landscape buffer, a minimum of one (1) tree and fifteen (15) shrubs, as specified above, must be planted and a continuous row of evergreen trees, not less than fourteen (14) feet in height, spaced in staggered groupings to form a minimum of an eighty (80) percent opaque buffer when planted. Trees may be located on either or both sides of any required wall; or c. Any combination of the above to achieve effective buffering and good landscape design. d. Where space allows, berms at a slope of not greater than three to one (3:1) may reduce required tree height by one (1) foot for each two (2) feet of berm height for those trees planted on the top of the berm. All berms must have at least a three (3) foot wide crest. 6. Open space. Development proposed in the R-2, R-3, MURC, and TCMU zoning designations shall provide an additional five (5) percent open space in addition to the required minimum. Developments proposed in the MURC and TCMU zoning designations can omit this provision, provided it meets the definition of infill development. 7. Landscaping. All developments shall meet the following landscaping requirements. a. Trees. The number of required trees shall be increased by twenty (20) percent above the minimum requirements for trees set forth in Article XI. Palm trees cannot comprise more than forty (40) percent of the total number of all required trees. b. Shrubs. The number of required shrubs shall be increased by twenty (20) percent above the minimum requirements for shrubs set forth in Article XI. All shrubs shall be sized in accordance to the following specifications: one-third (1/3) shall be a minimum of thirty-six (36) inches in height at the time of planting; one-third (1/3) shall be a minimum of eighteen (18) inches in height at the time of planting; and one-third (1/3) shall be ground cover plantings of a one (1) gallon size. c. Landscaping south of the coastal construction control line (CCCL). For that portion of a development area that lies along the CCCL, all landscaping shall only meet the landscaping standards set forth in the permit issued by the Department of Environmental Quality. 8. Pedestrian amenities. All developments shall provide gathering/sitting areas that at a minimum include the following decorative pedestrian amenities: benches, waste containers, planters, and pedestrian lighting fixtures. Other types of pedestrian amenities may be incorporated and include: decorative water fountains, sculptures, drinking fountains, phone booths and bicycle racks. G. Tier 3 Standards. In order to qualify for Tier 3 height, density and intensity bonuses, an applicant must demonstrate that they have met the Tier 2 supplemental standards, Tier 3 supplemental design analysis, and are providing "public benefits" as stated in subsection 2, below. 1. Supplemental design analysis. As part of the application for a Tier 3 project, the applicant shall demonstrate the impact of the project on access to light, impact on airflow dynamics, as well as the visual impacts that may adversely affect adjacent properties, motorists, pedestrians, or segments of the population. This shall be demonstrated by submitting architectural renderings, shadow analysis and/or other analyses that are appropriate to the character of the development proposed as determined by the Planning Director or designee. 2. Public benefits. The Planning Director shall be responsible for consulting with the applicant concerning the Tier 3 public benefit requirement of subsection b. The applicant shall bear the burden of demonstrating that the specific character, design, and investment commitment is a significant overall public benefit. The City retains the decision making power to determine whether the specific private investment, including the project amenities, together with the public benefits, commensurate with the increment of increased height, density or intensity that the applicant seeks. The final determination for what satisfies the Tier 3 public benefit requirement lies with City Council. In order for a project to be approved for the additional height, density, or intensity provided for in Tier 3, the applicant must meet, to the satisfaction of City Council, one (1) of the items listed below in subsections a thru e. a. Must provide one (1) of the following. i. Develop senior and/or student housing in the mixed use, medium or high density residential future land use designations in the comprehensive plan. An applicant must satisfy one of the following items or an equitable combination of the two (2). b. Developments located on property within the R-1 and R-2, TCMU, MUMS and MURC zoning designation shall either: i. Build one senior or student housing unit on the development site for each ten thousand (10,000) square feet of floor area developed, excluding areas devoted to structured parking and access ways; or ii. Dedicate two dollars ($2) per square foot of floor area developed into a dedicated "community housing fund" maintained by the City or a housing cooperative within the City of Gautier that would be used for the purpose of providing units owned and operated by seniors/ students. iii. Provide a proportionate combination of i. and ii. in such a manner that, for example, if half of the required housing units are physically provided, then one-half (1/2) of the two dollars ($2) per square foot dedication would be required. If seventy-five (75) percent of the required housing units are physically provided, then only twenty-five (25) percent of the two dollars ($2) per square foot dedication would be required. c. Relocation and conversion of above ground utilities to below ground locations. An applicant can qualify for Tier 3 bonuses by relocating and converting all above-ground utilities to below ground locations for that portion of the above ground utilities that are located on the subject property and that are in an adjacent right-of-way. Additionally, the applicant can choose to pay the City the amount it would cost for the relocation and conversion of the above ground utilities to below ground locations, based on a binding cost estimate provided by the power company, instead of performing the work. The City would then place the money into a separate fund (underground utility improvement fund), which would be used to accomplish several projects at once instead of piecemeal. d. Construct open space malls and arcades equipped with pedestrian-oriented furniture and streetscape that serve as gathering spaces for the general public. Encourage private investment in public gathering places. Site plans must demonstrate architecturally designed open space malls and arcades equipped with pedestrian-oriented furniture and streetscape. Pedestrian-oriented furniture and streetscape includes benches, trash receptacles, decorative light poles, paver blocks or stamped and colored concrete, water fountains, statues, splash pads, playgrounds, high quantity and quality landscaping, etc. e. Create and/or reinforce a pedestrian friendly transit system. Proposed developments shall provide wayfinding signage and construct a transit stop where the City has the greatest need for one in closest vicinity to the project, or make a monetary contribution to the City in the amount that would equal the cost of constructing a transit stop, or some combination of the two (2). 3. Additional required public benefits (must provide at least one (1)). a. Waterway access improvements. For improved access to the Waterways, this objective shall be carried forth through dedicating pedestrian easements to the public for access from public areas to the shoreline (public access points); the design, permitting, and construction of wetland and/or marsh walkovers facilities; boardwalks along creek, bayous. b. Off-site public parking garage. Non-residential uses located in the TCMU, MURC, MUMS, C-1, C-2, and C-3 districts are allowed to have up to eighty (80) percent of their required parking located in an off-site parking garage. However, the applicant must also provide an equivalent of thirty (30) percent of the total required parking space for the proposed development in the proposed off- site parking garage be dedicated to the City for public use. This dedication shall be in the form of a license and shall cover the above-mentioned parking spaces and the ingress/egress to said parking spaces. The off-site parking garage is not required to be located within the same district as the non-residential use. All required handicap parking spaces and loading spaces must be provided for on-site. c. Preserve significant view of Waterways. This incentive is applicable to sites that have direct access to rivers and bays and that have exceptional waterfront views that would clearly be imperiled without this incentive provision. In order to achieve the preservation of a significant view of the waterway the applicant shall be required to take the cumulative total of both side setbacks, minus fifteen (15) feet, and provide the entire combined setback on one (1) side of the property. The opposite side of the property shall provide a minimum fifteen (15) foot setback. d. Significant improvements to public infrastructure. In order to satisfy this objective, the applicant must prove that they are encouraging private investment in off-site infrastructure improvements. Such off-site improvements may be located anywhere within the City. This may be achieved by: purchasing and/or dedicating land for needed rights-of-way as indicated in the comprehensive plan or multi-modal plan, improving median landscaping; designing and building public parking located within city rights-of-way; constructing needed multi-use pathways or bikeways identified by the City, constructing recreational improvements; contributions, either in monetary or real property, that will hasten the implementation of any project identified in the Comprehensive Plan; and any other significant public benefit that enhances public infrastructure throughout the City. 4. Wetlands mitigation. Wetlands properties seeking mitigation for development and larger than five (5 )acres shall be eligible for Tier 3 status contingent on approval of said mitigation by the appropriate agencies. 5. Additionally, it is the expressed intent of this code that any Tier 3 public benefit has to be met prior to the issuance of any certificate of completion or occupancy for any portion of the development. Bonding a public benefit/improvement to receive Certificate of Completion or Occupancy for the development prior to the completion of the public benefit/improvement is expressly prohibited, unless special circumstances exist that are beyond the developer's control. In this case the City Manager may allow the developer to post a bond to ensure completion of the public benefit/improvement. If the City Manager decides against allowing the developer to post a bond to ensure completion of the public benefit/improvement, then the developer may appeal the City Manager's decision to the City Council.

Ask a question about Gautier law

Corpus searches the Gautier sections it holds and shows the ones that match, with their citations. Free, no sign-in.