For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12.4 — General Architectural Guidelines

Zoning Ordinance, City of Holly Springs, Mississippi; partial · Holly Springs Zoning Ordinance, § 12.4

Corpus is an independent public-information project, not the official City of Holly Springs website. Stable reference: corpuslaw.us/code/137389c1-7ffc-4c2b-8bd8-94be4d4e3003

12.4. General Architectural Guidelines

12.4.1. The City of Holly Springs strongly encourages interesting, articulated and high quality structures. Long or continuous wall planes should be avoided. Buildings should exhibit detail and elements appropriate for pedestrian view. 12.4.2. Lighting -Illumination shall be appropriate to site activities and site location. The minimum amount of illumination necessary for safety should be used. Exterior lighting of the building and site is to be designed so that light is not directed off the site and the light source is fully shielded from direct off-site viewing. 12.4.2.1. Exterior light sources may not be exposed and must be shielded from view, down cast and parallel with the ground. All luminaries (the complete lighting unit, consisting of the light source and all necessary mechanical, electrical and decorative parts) shall be “cut-off type” luminaries with elements such as shields, reflectors, or refractor panels which direct and cut off the emitted light at an angle of ninety degrees or less. 12.4.2.2. No exterior lighting fixture of any kind shall be so placed or directed such that the direct or reflected light there from shall interfere with the operation of automotive vehicles on any adjacent street. 12.4.2.3. No exterior light shall have any blinking, flashing, or fluttering light, or other illuminating device which has a changing light intensity or brightness of color 12.4.2.4. Exterior lighting is to be architecturally integrated with the building style, material and colors. 12.4.2.5. Lighting fixtures, whether mounted upon a building or independently upon a light standard, shall not exceed twenty-five feet (25’) in height. 12.4.2.6. Use of low, bollard-type lighting and landscape accent lighting is encouraged. 12.4.2.7. Raised light pole bases are to be attractively designed and detailed to be compatible with the overall project. Bases must be in a neutral color and not traffic yellow 12.4.2.8. Building mounted artificial light sources are to be shielded from public view, except for low intensity decorative lighting not exceeding forty-five (45) watts per bulb. 12.4.2.9. All exterior lighting must be listed by the developer on site plans, including a detailed lighting plan that includes the type, number, brightness, and type of cutoff/shielding for all fixtures. 12.4.3. Utilities

12.4.3.1. All on-site utilities shall be installed underground. Surface transformer switching pads shall be located and screened to be unobtrusive. In industrial zones, utilities may be located above ground, provided such utilities are on a steel pole and only on one side of the street. 12.4.4. Screening 12.4.4.1. Chain link fencing, including chain link fencing with slats or any other type of insert, is prohibited. 12.4.4.2. In highly visible public areas where fencing is needed, decorative fencing is required. Decorative fencing is defined as black wrought iron fencing or masonry fencing, or a combination thereof. 12.4.4.3. All exterior trash and storage areas, loading docks and ramps, and service areas are to be screened from view in a manner that is compatible with the building and site design. Screening materials should be the same as the primary building materials. The location of such services should be sited with limited visibility to public view and/or adjacent properties. Trash dumpsters and trash receptacle areas are to be screened with a masonry enclosure on three sides and gated. 12.4.4.4. Garbage collection areas shall be located at the rear of buildings. The following criteria shall also apply: 12.4.4.5. Dumpster enclosures shall be located on a concrete pad, of such size as recommended by the disposal company. 12.4.4.6. The approach to the dumpster area shall be paved of a hard surface Portland cement or asphaltic concrete, of a specification sufficient to support the weight and continual use of the garbage collection vehicle. 12.4.4.7. The screening on all enclosed dumpsters shall be a minimum of at least two (2) feet taller than the dumpster. 12.4.4.8. For compaction units, a floor drain shall be provided which ties to the sanitary sewer. 12.4.4.9. Either the dumpster enclosure must be constructed of sufficient size to accommodate all refuse materials to be recycled, such as grease barrels for restaurants and used oil barrels for automotive uses, or a separate enclosed pad of the same specification provided. 12.4.4.10. The use of wooden fences or chain-link fences with slats as a screening device for garbage collection areas is strictly prohibited. 12.4.4.11. Mechanical, communications, and service equipment, including satellite dishes and vent pipes, are to be totally screened from public view by parapets or walls. All building mounted equipment is to be screened by parapets or walls from ALL public views. 12.4.5. Sidewalks 12.4.5.1. Where the subject property does not already provide a public sidewalk, a five (5) foot wide sidewalk shall be constructed along the entire street frontage of the property. The sidewalk shall be constructed to align with

existing sidewalks on adjacent properties. Where sidewalks are not yet present on adjacent properties, the sidewalk shall be constructed at least five (5) feet back from the curb to allow for green space and street trees. In the instance of a corner lot, the sidewalk will be constructed along both street frontages, with handicap access ramps constructed at the street corner. 12.4.5.2. Crosswalks. Crosswalks shall be provided both internally and externally to the development. Public crosswalks shall be striped in conformance with the latest edition of the Manual on Uniform Traffic Control Devices. Private crosswalks, internal to the site, shall be delineated by materials of a different color and texture from the surrounding parking lot (brick, cobblestone, etc. preferred) or by white, reflectorized pavement striping. 12.4.5.3. Street Signs and Traffic Control Devices. When, as the result of the proposed project, street signs, traffic signals, or traffic regulatory signs are required, the applicant shall be responsible for the installation of such devices and signs, the design of which shall be integrated into the overall site design. 12.4.6. Retaining Walls: 12.4.6.1. The height and length of retaining walls should be minimized with appropriate landscaping. Retaining walls should be designed to incorporate elements of other architectural features or natural features of the project 12.4.6.2. Materials utilized for the retaining walls should match the primary building material. Plantable walls allowing for the growth of vegetation are encouraged. 12.4.7. Signs 12.4.7.1. All signs are to be architecturally integrated and complement their surroundings in terms of size, shape, color, texture and lighting. Signs are to complement the overall design of the building and are not to be designed to be in visual competition with other signs in the area. Signs must adhere to these regulations. 12.4.8. Materials and Colors: 12.4.8.1. Materials should have good architectural character, be durable, and be selected for their compatibility with adjoining buildings and properties. Natural, traditional building materials are encouraged. Highly reflective and/or synthetic materials are discouraged. 12.4.8.2. Exterior materials should be selected based on their durability and appropriateness for their intended function. Special attention should be given to the durability of materials used around the ground floor of the building. Preferred building materials include stone, brick, cement board, cementuous stucco, and wood. The materials selected should

require minimal maintenance. Their color should be integral to the material and not painted on (except in the case of wood). No more than three (3) painted or applied colors may be used on the exterior of any building. Colors of the predominate exterior surface material should be subdued, with natural tones and neutral colors predominating. 12.4.8.3. Exterior Insulating Finishing (EFIS) and concrete masonry should not be the predominant building material. EIFS should be used as a way to accentuate an architectural element and should be limited to areas not subject to damage or abuse (lower parts of buildings). Concrete masonry should be limited to split face or burnished units. Painted, flat-faced concrete masonry units are prohibited. 12.4.8.4. Warehouse or manufacturing areas of industrial buildings may utilize metal veneer surface or pre-cast concrete panels which are tinted or colored with the approval of the Site and Design Committee. 12.4.8.5. Architectural consistency of colors, materials and detailing are to be provided between all building elevations. False or decorative façade treatments, where one or more unrelated materials are placed upon the building are prohibited. Large parapet walls should reflect the function behind them and should not be freestanding. All elevations need not look alike; however, a sense of overall architectural continuity is strongly encouraged. 12.4.8.6. Inconsistent adornment and frequent changes in material should be avoided. 12.4.8.7. All buildings should be designed to be compatible with the character of the community. 12.4.8.8. With the exception of industrial uses, the maximum unbroken facades plane shall be fifty (50) feet for multiple-family residential uses, and sixty (60) feet for commercial and office uses. The wall of any such building shall be interrupted through the use of projections or recesses, portals, courtyards, plazas or other appropriate architectural conventions. The design of off-setting wall plane projections or recesses shall have a minimum depth of two (2) feet. 12.4.8.9. No flat-faced cement block or metal surfaces shall be visible upon the exterior of any building. 12.4.8.10. Where pitched roofs are utilized, the primary roof form shall be on a slope of no less than 6/12. Porches shall be on a slope of not less than 3/12. Pitched roofs shall be shingled with wood textured composition shingles or architectural shingles. Roof design should be appropriate for the architectural style of the building. Enameled standing seam metal, flat tiles of concrete or clay, and copper metal roofs are permitted. All surfaces are permitted when the roof is concealed from public view by parapets (flat, built up or pitched roofs). The use of plastic, fiberglass,

other metal, or glass, visible to public view, is strictly prohibited. The use of bright, high intensity colors is strictly prohibited. 12.4.8.11. The treatment of doors and windows shall be uniform throughout the building design, with the exception of designated fire doors located on the rear of the building. 12.4.8.12. Parapet facades may be used when of unified construction with the primary surface of the wall and of the same material and color. The parapet shall be design such that the reverse side of all elements shall not be visible to public view. False mansards are prohibited. Canopies are permissible provided they are an integrated part of the overall building design, are not used to create the impression of a false mansard, and are not used as a location or support for wall-mounted signage (painted signs on canopies are permitted). 12.4.9. Landscaping and Parking 12.4.9.1. Landscaping is used in parking areas to reduce heat radiated from paving, improve auto circulation and safety, and to screen parked automobiles from public view. 12.4.9.2. A consistent landscape treatment along public streets enhances the appearance of the public domain, and provides an attractive, unified setting for variations among individual developments. Landscaped areas should dominate the frontage of any site where entries are the only interruption. Although the type and nature of the landscaping between individual properties may vary, the design and depth of landscape areas shall be consistent as they transition from one property to another. 12.4.9.3. A minimum of one (1) large deciduous shade tree for every thirty-five (35 feet of lineal street frontage or portion thereof shall be planted upon the subject property within the area five (5) feet behind the street ROW line up to said street ROW line. The size of the trees at planting is to be 3 ½ caliper as measured six (6) inches above the ground. 12.4.9.4. Parking areas shall be organized as a series of small parking bays with landscape islands separating them. A landscape island shall be place for each 10 parking spaces as follows: 12.4.9.5. Single-loaded parking rows - a raised island, not less than six (6) inches in height, five (5) feet wide by twenty (20) feet in length shall be located at both ends of every single-loaded parking row and for every 10 parking spaces. This island shall contain a minimum of one (1) medium deciduous shade tree, 2 ½ inches in caliper as measured six inches above the ground, and low shrubs at least eighteen (18) inches high. 12.4.9.6. Double-loaded parking rows – a raised island, not less than six (6) inches in height, ten (10) feet wide by forty (40) feet in length shall be located at both ends of every single-loaded parking row and for every 10 parking spaces. This island shall contain a minimum of two (2) medium

deciduous shade trees, 2 ½ inches in caliper as measured six inches above the ground, and low shrubs at least eighteen (18) inches high. 12.4.9.7. Where parking areas adjoin public streets, an opaque barrier, a minimum and maximum of three (3) feet above the elevation of the adjacent parking areas shall be provided between the parking area and the street ROW line, for the length of the parking area, to obscure parked vehicles within these areas from public view, and to prevent the lights from parked vehicles encroaching upon the public street. The barrier may take the form of a decorative masonry wall with plantings on the street frontage, an earthen berm with established ground cover, or dense shrubbery of sufficient density to present an uninterrupted vegetative wall. 12.4.9.8. Trees planted for the purpose of complying with the perimeter landscaping requirements shall not be double counted for compliance with the interior landscaping requirements. 12.4.9.9. Ground cover. Areas adjacent to streets and pedestrian walkways, as well as interior landscaped areas, shall be treated with grass, mulch or other types of vegetative ground cover. 12.4.9.10. Irrigation. In order to present a healthy, neat and orderly appearance, landscaped areas shall be provided with adequate irrigation for the maintenance of grass, shrubs, and trees by utilizing a sprinkler system or hose bibs. 12.4.9.11. Whenever possible, healthy existing trees should be maintained, as they are an amenity that increases the value of property and requires many years to replace. All existing trees eight (8) inches or larger or significant tree canopy, must be identified on the site plan. 12.4.9.12. The trees, shrubs, and other landscaping materials depicted upon the approved Development Plan shall be considered as elements of the project. The applicant and his successors, assign, and/or subsequent owners and their agents shall be responsible for the continued maintenance of all landscaping materials. Plant material which exhibits evidence of insects, disease or damage shall be appropriately treated. Dead plants shall be removed and replaced within thirty (30) days following notification by the Village. 12.4.9.13. A planted bufferyard of at least twenty (20) feet is required between any commercial, industrial, multiple-family residential, or institutional use and any single-family use. Bufferyards shall be located on the outer perimeter of a lot or parcel, extending to the lot or parcel line, alongside and rear property lines. Bufferyards shall not be located on any portion of a public or private street ROW. A decorative masonry wall of brick, cementuous stucco, or natural stone, six feet in height, with support columns no further apart than ten (10) feet may be used instead of the

planted area, or in conjunction with the planted material. Decorative wrought iron may be used in conjunction with the fencing materials and with landscaping of sufficient density to maintain the integrity of the wall as an effective barrier. The use of wood or chain link fencing as an opaque barrier is strictly prohibited. Bufferyards shall contain one (1) large deciduous tree (ultimate height of 50+ feet), three medium (ultimate height of 25’) evergreen trees (planted on a twenty-five foot triangular staggered spacing), and one small ornamental tree for every seventy-five (75) lineal feet of bufferyard, 12.4.9.14. All landscaping shall be in accordance with the approved plant list in Appendix “A” [Reserved]. 12.4.10. Off-site Improvements - Where off-site roadway or utility improvements are required as a result of the proposed development (due to impact), those improvements shall the responsibility of the applicant, and shall be constructed or installed prior to any final inspection or the issuance of an occupancy permit.

Ask a question about Holly Springs law

Corpus searches the Holly Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.