For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 40-21 — Definitions

Code of Ordinances, City of Horn Lake, Mississippi (Supp. No. 13: codified through Ordinance No. 25-08-314, adopted August 19, 2025 (online updated October 24, 2025; adopted-not-yet-codified ordinances 25-10-316/317 listed separately, not shipped)) · Horn Lake Code of Ordinances § 40-21

Corpus is an independent public-information project, not the official City of Horn Lake website. Stable reference: corpuslaw.us/code/1dc6b41c-263d-42d1-8d5e-fca004b79dbf

Sec. 40-21. - Definitions.

The following words, terms, phrases, when used in this article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning. Air gap means a physical separation sufficient to prevent backflow between the free-flowing discharge end of the potable water system and any other system. The term "air gap" is physically defined as a distance equal to twice the diameter of the supply side pipe diameter but never less than one inch. Approved means accepted by the city as meeting an applicable specification stated or cited in this article, or as suitable for the proposed use. Atmospheric vacuum breaker means a device which prevents back-siphonage by creating an atmospheric vent when there is either a negative pressure or sub-atmospheric pressure in a water system. Auxiliary water supply means any water supply, on or available, to the premises other than the city's approved public potable water supply. Backflow means the flow of water or other liquids, mixtures or substances, under positive or reduced pressure in the distribution pipes of a potable water supply from any source other than its intended source. Backflow preventer means a device or means designed to prevent backflow or back-siphonage and is most commonly categorized as air gap, reduced pressure principal device, double check valve assembly, pressure vacuum breaker, atmospheric vacuum breaker, hose bibb vacuum breaker, residential dual check, double check with intermediate atmospheric vent, all of which terms are elsewhere defined herein. Backpressure means a condition in which the owner's system pressure is greater than the supplier's system pressure. Back-siphonage means the flow of water or other liquids, mixtures or substances into the distribution pipes of a potable water supply system from any source other than its intended source caused by the sudden reduction of pressure in the potable water supply system. Containment means a method of backflow prevention which requires a backflow preventer at the water service entrance. Contaminant means a substance that will impair the quality of the water to a degree that it creates a serious health hazard to the public leading to poisoning or the spread of disease. Cross connection means any actual or potential connection between the public water supply and a source of contamination or pollution. Department of health means the state department of health, division of water supply. Double check valve assembly means an assembly of two independently operating spring loaded check valves with tightly closing shut-off valves on each side of the check valves, plus properly located test cocks for the testing of each check valve. Double check valve with intermediate atmospheric vent means a device having two spring loaded check valves separated by an atmospheric vent chamber. Fixture isolation means a method of backflow prevention in which a backflow preventer is located to correct a cross connection at an in-plant location rather than at a water service entrance. Health hazard (high hazard) means contamination with the potential to endanger the health and well-being of the water customers or owners. Hose bibb vacuum breaker means a device which is permanently attached to a hose bibb and which acts as an atmospheric vacuum breaker. Non-potable water means water not acceptable for human consumption or of unknown quality. Non-health hazard (low hazard) means not harmful to health, but would still be objectionable. Owner means any person who has legal title to, or license to operate or habitat in, a property upon which a cross connection inspection is made or upon which a cross connection is present. Person means any individual, partnership, company, public or private corporation, political subdivision, department, agency or instrumentality of the state or the United States or any other legal entity. Permit means a document issued by the city or its designated representative, which allows the use of a backflow preventer. Pollutant means a foreign substance that, if permitted to get into the public water system, will degrade its quality so as to constitute a high hazard, or impair the usefulness or quality of the water to a degree which does not create an actual hazard to the public health but which does adversely and unreasonably affect such water for domestic use. Potable water means water that is acceptable for human consumption. Pressure vacuum breaker means a device containing one or two independently operated spring loaded check valves and an independently operated spring loaded air inlet valve located on the discharge side of the check or checks. Such device includes tightly closing shut off valves on each side of the check valves and properly located test cocks for the testing of the check valve. Reduced pressure principal backflow preventer means an assembly consisting of two independently operating approved check valves with an automatically operating differential relief valve located between the two check valves, tightly closing shut-off valves on each side of the check valves plus properly located test cocks for the testing of the check valves and the relief valve. Residential dual check means an assembly of two spring loaded, independently operating check valves without tightly closing shut-off valves and test cocks, generally employed immediately downstream of the water meter to act as a containment device. Water service entrance means that point in the owner's water system beyond the sanitary control of the city; it is generally considered to be the outlet end of the water meter and is always located before any unprotected branch. Water system means the public water system of the city.

(Ord. No. 00-12-103, § III, 12-5-2000)

Ask a question about Horn Lake law

Corpus searches the Horn Lake sections it holds and shows the ones that match, with their citations. Free, no sign-in.