Sec. 8-53. - Additions, insertions, deletions and changes.

(a) 2024 edition of the International Building Code. The following sections are hereby revised: Section 101.1. Insert: City of Horn Lake, Mississippi Section 109 Fees. [A] 109.4 Work commencing before permit issuance. Any person who commences any work on a building, structure, electrical, gas, mechanical or plumbing system before obtaining the necessary permits shall be subject to a fee established by the building official that shall be in addition to the required permit fees. Such fees shall be established as double the permit fee required. Section 113. BOARD OF APPEALS Section 113.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the building official relative to the application and interpretation of this code, there shall be and is hereby created a board of appeals. The board of appeals shall be the governing authority and shall hold office at its pleasure. The board shall adopt rules of procedure for conducting its business. Section [A] 113.3 Qualifications. The board of appeals shall consist of members who are qualified by experience and training to pass on matters pertaining to building construction. Owner or Occupants that wish to appeal a decision by the Building Code Official made pursuant to this ordinance or the International Fire Code or Building Code may do so by filing a written appeal to the Horn Lake Mayor and Board of Aldermen within ten (10) days of the Code Official's decision. The provision of this ordinance shall not be held to deprive any Federal and State Agency, or any applicable governing body having jurisdiction, of any power or authority which it had on the effective date of the adoption of this ordinance or of any remedy then existing for enforcement of its order, nor shall it deprive any individual or corporation of its legal rights as provided by law. Section 1612.3. Insert: City of Horn Lake, Mississippi Section 1612.3. Insert; August 7, 2007 Chapter 9: Fire Protection Systems GENERAL SPRINKLER REQUIREMENTS An approved automatic sprinkler system shall be provided for in the following new buildings and those undergoing substantial improvement as defined in this ordinance and the ICC: All requirements of the International Building and Fire Code will be followed with the following revisions and additions: Section 902.1 Pump and riser room size. Add: Fire pump and automatic sprinkler system riser rooms shall be provided with an exterior door(s) and unobstructed passageway large enough to allow removal of the largest piece of equipment. Section 903.2.1.1 Group A-1 1. Will read: The fire area exceeds 8,000 square feet. Section 903.2.1.3 Group A-3 1. Will read: The fire area exceeds 8,000 square feet. Section 903.2.1.4 Group A-4 1. Will read: The fire area exceeds 8,000 square feet. Group B Business (per occupancy classification International Building Code) The fire area exceeds 8,000 square feet. Section 903.2.3 Group E 1. Will read: Throughout all Group E fire areas. Section 903.2.4 Group F-1 1. Will read: Where a Group F-1 fire area exceeds 8,000 square feet. 3. Will read: Where the combined area of all Group F-I fire areas on all floors, including any mezzanines, exceeds 16,000 square feet. Group F-2 Factory Industrial F-2 Low-hazard Occupancy 1. Where a Group F-2 fire area exceeds 8,000 square feet. 2. Where the combined area of all Group F-2 fire areas on all floors, including any mezzanines, exceeds 16,000 square feet. Section 903.2.7. Group M 1. Will read: Where Group M fire area exceeds 8,000 square feet. 2. Will read: Where the combined area of all Group M fire areas on all floors, including any mezzanines, exceeds 16,000 square feet. Section 903.2.9 Group S-I 1. Will read: Where a Group S-I fire area exceeds 8,000 square feet. 3. Will read: Where the combined area of all S-I fire areas on including any all floors mezzanines, exceeds 16,000 square feet. Section 903.2.9.1 Repair Garages 1. Will read: Buildings two or more stories in height, including basements, with a fire area containing a repair garage exceeding 6,700 square feet. 2. Will read: One-story buildings with a fire area containing a repair garage exceeding 8,000 square feet. Section 903.2.9.2 Bulk storage of tires Will read: Buildings and structures where the area for the storage of tires exceeds 13,400 cubic feet shall .... Section 903.2.10. Group S-2 Will read: An automatic sprinkler system shall be provided throughout all buildings containing a Group S-2 occupancy where one of the following conditions exists: 1. Where a Group S-2 fire area exceeds 8,000 square feet; Section 903.4.2 Alarms. Add: All Buildings that are required to have a fire sprinkler system shall provide in each tenant space visible/audible warning device(s) that actuation of the sprinkler system or fire alarm system will activate the device. Section 905. Standpipe Systems Section 905.3.1 Height (1) Three (3) or more stories above or below grade plane. Fire Walls: For the purpose of fire sprinkler separation footage, only four (4) hour rated firewalls with fire rated assemblies protecting all openings will separate building occupancies. (FIRE WALL) A (4) four-hour fire resistant wall that meets these requirements: Structural stability. Fire walls shall have sufficient structural stability under fire conditions to allow collapse of construction on either side without collapse of the wall for the duration of 4 hours. Horizontal continuity. Fire walls shall be continuous from exterior wall to exterior wall and shall extend at least 18 inches (457 mm) beyond the exterior surface of exterior walls. Vertical continuity. Fire walls shall extend from the foundation to a termination point at least 30 inches (762 mm) above both adjacent roofs. Openings in the roof shall not be located within 4 feet (1220 mm) of the fire wall. General truss marking requirements are in accordance with City of Horn Lake Ordinance #09-11-194. (b) 2024 edition of the International Fire Code. The following sections are hereby revised: Section 101.1. Insert: City of Horn Lake Section 105.1 Add: Fees are established by order or resolution of the governing authority. Section 109.1 Board of appeals established. In order to hear and decide appeals of orders, decisions or determinations made by the fire code official relative to the application and interpretation of this code, there shall be and is hereby created a board of appeals. The board of appeals shall be the governing body and shall hold office at its pleasure. The fire code official shall be an ex officio member of said board but shall have no vote on any matter before the board. The board shall adopt rules of procedure for conducting its business, and shall render all decisions and findings in writing to the appellant with a duplicate copy to the fire code official. Section 109.3 Qualifications. The board of appeals shall consist of members who are qualified by experience and training to pass on matters pertaining to hazards of fire, explosions, hazardous conditions or fire protection systems. Owner or Occupants that wish to appeal a decision by the Fire Code Official made pursuant to this ordinance or the International Fire Code or Building Code may do so by filing a written appeal to the Horn Lake Mayor and Board of Aldermen within ten (10) days of the Fire Code Official's decision. The provision of this ordinance shall not be held to deprive any Federal and State Agency, or any applicable governing body having jurisdiction, of any power or authority which it had on the effective date of the adoption of this ordinance or of any remedy then existing for enforcement of its order, nor shall it deprive any individual or corporation of its legal rights as provided by law. Section 110.4. Insert: Misdemeanor, $1,000, 90 days Section 112.4. Insert: $250.00, $1,000 Chapter 9: Fire Protection Systems GENERAL SPRINKLER REQUIREMENTS An approved automatic sprinkler system shall be provided for in the following new buildings and those undergoing substantial improvement or occupancy change as defined in this ordinance and the International Fire Code. All requirements of the International Fire Code will be followed with the following revisions and additions: Section 901.4.6. ... Add: Fire pump and automatic sprinkler system riser rooms shall be provided with an exterior door(s) and an unobstructed passageway large enough to allow removal of the largest piece of equipment. Section 903.2.1.1 Group A-1 1. Will read: The fire area exceeds 8,000 square feet. Section 903.2.1.3 Group A-3 1. Will read: The fire area exceeds 8,000 square feet. Section 903.2.1.4 Group A-4 1. Will read: The fire area exceeds 8,000 square feet. Group B Business (per occupancy classification International Building Code) The fire area exceeds 8,000 square feet. Section 903.2.3 Group E 1. Will read: Throughout all Group E fire areas. Section 903.2.4 Group F-1 1. Will read: Where a Group F-1 fire area exceeds 8,000 square feet. 3. Will read: Where the combined area of all Group F-I fire areas on all floors, including any mezzanines, exceeds 16,000 square feet. Group F-2 Factory Industrial F-2 Low-hazard Occupancy 1. Where a Group F-2 fire area exceeds 8,000 square feet. 2. Where the combined area of all Group F-2 fire areas on all floors, including any mezzanines, exceeds 16,000 square feet. Section 903.2.7. Group M 1. Will read: Where Group M fire area exceeds 8,000 square feet. 3. Will read: Where the combined area of all Group M fire areas on all floors including any mezzanines, exceeds 16,000 square feet. Section 903.2.9 Group S-I 1. Will read: Where a Group S-I fire area exceeds 8,000 square feet. 3. Will read: Where the combined area of all S-I fire areas on all floors including any mezzanines, exceeds 16,000 square feet. Section 903.2.9.1 Repair Garages 1. Will read: 1. Buildings having two or more stories above grade plane, including basements, with a fire area containing a repair garage exceeding 6,700 square feet 2. Will read: Buildings no more than one story above grade plane, with a fire area containing a repair garage exceeding 8,000 square feet. Section 903.2.9.2 Bulk storage of tires Will read: Buildings and structures where the area for the storage of tires exceeds 13,400 cubic feet shall .... Section 903.2.10 Group S-2 Will read: An automatic sprinkler system shall be provided throughout all buildings containing a Group S-2 occupancy where one of the following conditions exists: 2. Where a Group S-2 fire area exceeds 8,000 square feet; Mixed Occupancies All buildings 8000 square feet or greater fire area not separated by the approved four hour firewall set forth in this ordnance shall have a fire sprinkler system. Multi-Tenant Occupancy Every other potential occupancy space shall have a monitored sprinkler cutoff valve and waterflow switch installed for accurate response from Fire Department personnel and to eliminate potential hazard from the entire building being disconnected from water system during construction of future tenant spaces. Section 903.4.2 Alarms. Add: All Buildings that are required to have a fire sprinkler system shall provide in each potential tenant space visible/audible warning device(s) that actuation of the sprinkler system or fire alarm system will activate the device. Commercial/Industrial Sprinkler Service All fire service mains or hydrants that are part of a Commercial/Industrial Fire Suppression system Fire Loop shall be installed by a licensed sprinkler contractor who shall install the underground portion of the fire suppression system beginning at the City connection with approved materials. Fire Loop Hydrants shall be located not less than 40 ft (12.2 m) from the buildings to be protected. Hydrants shall be installed so that the steamer cap opening is facing the street and clears the finished grade by 18" or more in height. Any building larger than one story, requiring a sprinkler system, shall have the fire department connection placed away from the building. All fire department connections shall be a 5 inch Storz connection on a 30 degree elbow, placed no less than one and a half times the height of the building away, in an area approved by the fire code official. The fire department connection shall be placed within 100 feet of a hydrant. For the purpose of this Ordinance, occupancies shall be classified in accordance with International Building and Fire codes. Any change of occupancy or change of hazard or class of hazard will require compliance with this code. For the purpose of this Ordinance any building undergoing substantial improvement shall be brought to current code: SUBSTANTIAL IMPROVEMENT. For the purpose of determining compliance with this ordinance, any repair, alteration, addition, or improvement of a building or structure, the cost of which equals or exceeds 50 percent of the assessed tax value of the structure, before the improvement or repair is started or the work area exceeds 50 percent of the gross floor area. If the structure has sustained substantial damage, any repairs are considered substantial improvement regardless of the actual repair work performed. Any addition to an existing building which brings the gross floor area above the applicable square footage listed in the above articles shall cause the entire building to meet the requirement of that section. Where these requirements conflict with the City of Horn Lake Building Code, State, Federal standards or local requirements, the most stringent shall apply. Fire Walls: For the purpose of fire sprinkler separation footage, only four (4) hour rated firewalls with fire rated assemblies protecting all openings will separate building occupancies. (FIRE WALL) A (4) four-hour fire resistant wall that meets these requirements: • Structural stability. Fire walls shall have sufficient structural stability under fire conditions to allow collapse of construction on either side without collapse of the wall for the duration of 4 hours. • Horizontal continuity. Fire walls shall be continuous from exterior wall to exterior wall and shall extend at least 18 inches (457 mm) beyond the exterior surface of exterior walls. • Vertical continuity. Fire walls shall extend from the foundation to a termination point at least 30 inches (762 mm) above both adjacent roofs. Openings in the roof shall not be located within 4 feet (1220 mm) of the fire wall. General truss marking requirements are in accordance with City of Horn Lake Ordinance #09-11-194 SECTION 506 KEY BOXES Section 506.1 Where required. Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the fire code official is authorized to require a key box to be installed by the property owner in an approved location. The key box shall be of an approved type and shall contain keys to gain necessary access as required by the fire code official. Manufacture specifications shall be used to determine number of keys to be allowed to be stored in box. Due consideration shall be given to box size needed. Section 506.1.1 Locks. An approved lock shall be installed by the property owner on gates or similar barriers when required by the fire code official. Two- position electric override key switch shall be installed by the property owner for emergency access to gated communities, apartment complexes, parking garages and industrial gated areas and to control electrical equipment vital to emergency operations. That the geographic limits referred to in certain sections of the 2018 International Fire Code are hereby established as follows: Section 5704.2.9.6.1 (geographic limits in which the storage of Class I and Class II liquids in above-ground tanks outside of buildings is prohibited): M1, M2, PBP per Zoning Ordinance Section 5706.2.4.4 (geographic limits in which the storage of Class I and Class II liquids in above-ground tanks is prohibited): M1, M2, PBP per Zoning Ordinance Section 5806.2 (geographic limits in which the storage of flammable cryogenic fluids in stationary containers is prohibited): M1, M2, PBP per Zoning Ordinance Section 6104.2 (geographic limits in which the storage of liquefied petroleum gas is restricted for the protection of heavily populated or congested areas): M1, M2, PBP Per Zoning Ordinance (c) 2024 edition of the International Residential Code. The following sections are hereby revised: Section R101.1. Insert: City Of Horn Lake Mississippi Section R108.5 Refunds. The building official is authorized to establish a refund policy. The policy is as follows: 1. The building official may authorize refunding of any fee paid hereunder which was erroneously paid or collected. 2. The building official may authorize refunding of not more than 80 percent of the permit fee paid when no work has been done under a permit issued in accordance with the adopted code. 3. The building official may authorize refunding of not more that 80 percent of the plan review fee paid when an application for a permit for which a plan review fee has been paid is withdrawn or canceled before any plan reviewing is done. 4. The building official shall not authorize refunding of any fee paid except on written application filed by the original permittee not later than six months after the date of payment. Section R108.6 Add: This fee is hereby established as double the required permit fee up to a maximum amount of $5,000. Section R112.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the building official relative to the application and interpretation of this code, there shall be and is hereby created a board of appeals. The building official shall be an ex officio member of said board but shall have no vote on any matter before the board. The board of appeals shall be the governing body and shall hold office at its pleasure. The board shall adopt rules of procedure for conducting its business, and shall render all decisions and findings in writing to the appellant with a duplicate copy to the building official. Table R301.2 (1) TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND SNOW LOAD | WIND DESIGN | SEISMIC DESIGN CATEGORY f | SUBJECT TO DAMAGE FROM | WINTER DESIGN TEMP e | ICE BARRIER UNDERLAYMENT REQUIRED h | FLOOD HAZARDS g | AIR FREEZING INDEX i | MEAN ANNUAL TEMP j Speed d (mph) | Topographic effects k | Weathering a | Frost line depth b | Termite c 10 inches | 90 | Site Specific | D 0 | Moderate | 13 Inches | Very Heavy | 20 Deg. | NO | NFIP | 250 | 60 Deg Section P2603.5.1 Insert: 14, 14 Section R313.2 One family dwellings automatic fire systems. An automatic residential fire sprinkler system shall be installed in one family dwellings that are five thousand (5,000) square feet aggregate or more under roof. Multiple family and Two-family dwellings automatic fire sprinkler systems. An automatic residential fire sprinkler system shall be installed all multiple family dwellings. Lodging, Rooming/ Boarding Houses and Bed and Breakfast. An automatic residential fire sprinkler system shall be installed in all lodging, rooming and bed and breakfast establishments. Exception: An automatic residential fire sprinkler system shall not be required for additions or alterations to existing buildings that are not already provided with an automatic residential sprinkler system unless alterations or additions exceed the outlined sections below. • ALTERATION is any construction or renovation to an existing structure other than a repair or addition and shall not require the installation of a residential fire sprinkler system. • REPAIR is the restoration to good or sound condition of any part of an existing building for the purpose of its maintenance and shall not require the installation of a residential fire sprinkler system. • ADDITION. An extension or increase in floor area, number of stories, or height of a building or structure that brings the total aggregate area of the building to less than 5000 square feet under roof shall not be required to install a residential fire sprinkler system. Additions that bring the total aggregate area equal to or greater than 5000 square feet under roof shall be provided with an automatic residential fire sprinkler system. (d) 2024 edition of the International Existing Building Code. The following sections are hereby revised: Section 101.1 Insert: City of Horn Lake, Mississippi (e) 2024 edition of the International Property Maintenance Code. The following sections are hereby revised: Section 101.1. Insert: City of Horn Lake, Mississippi Section 103.5. Insert: See city fee schedule Section 112.4. Insert: Min. $250.00, Max $1,000 Section 302.4. Insert: Six inches Section 304.14. Insert: January 1, December 31 Section 602.3. Insert: January 1, December 31 Section 602.4. Insert: January 1, December 31 (f) 2024 edition of the National Electrical Code NFPA 70. The following sections are hereby revised: None. (g) 2024 edition of the International Energy Conservation Code. The following sections are hereby revised: Sections C101.1 and R101.1. Insert: Horn Lake, Mississippi Sections C108.4 and R108.4. Insert: $250.00, $1,000 (h) 2024 edition of the International Fuel Gas Code. The following sections are hereby revised: Section 101.1. Insert: City of Horn Lake, Mississippi Section 106.6.2. Insert: See city fee schedule Section 106.6.3. Insert: Refunds. The building official is authorized to establish a refund policy. The policy is as follows: 1. The building official may authorize refunding of any fee paid hereunder which was erroneously paid or collected. 2. The building official may authorize refunding of not more than 80 percent of the permit fee paid when no work has been done under a permit issued in accordance with the adopted code. 3. The building official may authorize refunding of not more that 80 percent of the plan review fee paid when an application for a permit for which a plan review fee has been paid is withdrawn or canceled before any plan reviewing is done. 4. The building official shall not authorize refunding of any fee paid except on written application filed by the original permittee not later than six months after the date of payment. Section 108.4. Insert: Misdemeanor, $1,000, 90 days Section 108.5. Insert: Min. $250.00, Max $1,000 (i) 2024 edition of the International Mechanical Code. The following sections are hereby revised: Section 101.1. Insert: City of Horn Lake Section 106.5.2. Insert: See fee schedule Section 106.5.3. Insert: Refunds. The building official is authorized to establish a refund policy. The policy is as follows: 1. The building official may authorize refunding of any fee paid hereunder which was erroneously paid or collected. 2. The building official may authorize refunding of not more than 80 percent of the permit fee paid when no work has been done under a permit issued in accordance with the adopted code. 3. The building official may authorize refunding of not more that 80 percent of the plan review fee paid when an application for a permit for which a plan review fee has been paid is withdrawn or canceled before any plan reviewing is done. 4. The building official shall not authorize refunding of any fee paid except on written application filed by the original permittee not later than six months after the date of payment. Section 108.4. Insert: Misdemeanor, $1,000, 90 days Section 108.5. Insert: $250.00, $1,000 Section 506.3.2.5 Grease duct test. Prior to the use or concealment of any portion of a grease duct system, a leakage test shall be performed. Ducts shall be considered to be concealed where installed in shafts or covered by coatings or wraps that prevent the ductwork from being visually inspected on all sides. The permit holder shall be responsible to provide the necessary equipment and perform the grease duct leakage test. A smoke test shall be performed to determine that all welded and brazed joints are liquid tight. A smoke test shall be performed by sealing all intakes and exhaust ducts at their termination points and dropping smoke emitters with enough smoke to positively charge the ducts with smoke. A test shall be performed for the entire duct system, including the hood-to-duct connection. The duct work shall be permitted to be tested in sections, provided that every joint is tested. For listed factory-built grease ducts, this test shall be limited to duct joints assembled in the field and shall exclude factory welds. (j) 2024 edition of the International Plumbing Code. The following sections are hereby revised: Section 101.1. Insert: City of Horn Lake, Mississippi Section 106.6.2. Insert: See City fee schedule Section 106.6.3. Insert: Refunds. The building official is authorized to establish a refund policy. The policy is as follows: 1. The building official may authorize refunding of any fee paid hereunder which was erroneously paid or collected. 2. The building official may authorize refunding of not more than 80 percent of the permit fee paid when no work has been done under a permit issued in accordance with the adopted code. 3. The building official may authorize refunding of not more that 80 percent of the plan review fee paid when an application for a permit for which a plan review fee has been paid is withdrawn or canceled before any plan reviewing is done. 4. The building official shall not authorize refunding of any fee paid except on written application filed by the original permittee not later than six months after the date of payment. Section 108.4. Insert: Misdemeanor, $1,000, 90 days Section 108.5. Insert: $250.00, $1,000 Section 305.4.1. Insert: 14, 14

(Ord. No. 14-02-215, § 2, 2-4-2014; Ord. No. 21-02-270, § 2, 2-23-2021; Ord. No. 25-03-308, § 2, 3-18-2025)

Ask a question about Horn Lake law

Corpus searches the Horn Lake sections it holds and shows the ones that match, with their citations. Free, no sign-in.