For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 22-73 — Requirements for rooftop heliports

Code of Ordinances, City of Jackson, Mississippi (Supp. No. 56: codified through Ordinance No. 2026-11(3), enacted February 24, 2026) · Jackson Code of Ordinances § 22-73

Corpus is an independent public-information project, not the official City of Jackson website. Stable reference: corpuslaw.us/code/289372a7-53a8-430b-9361-c37b37b2abaf

Sec. 22-73. - Requirements for rooftop heliports.

Where a heliport licensed under the provisions of this article is to be situated on a rooftop, the following shall be required: (1) Smoking shall be prohibited on the roof operating areas during landing and takeoff operations. (2) Persons other than heliport personnel shall be restricted to designated, protected waiting areas during aircraft landing and takeoff operations. (3) The waiting area shall be enclosed with a substantial metal fence or skirt. (4) Roof construction shall be incombustible, nonabsorbent, not less than two-hour fire resistive, and no loose material, such as gravel, shall be used as roof covering. (5) All construction on the roof shall be of noncombustible material. (6) Openings in the roof shall not be permitted in the immediate landing area. Openings outside the immediate landing area shall be curbed with incombustible material, at least six inches high, and protected from flammable liquid spillage and impact. (7) Flammable liquid spillage shall be confined to the roof surface at the landing area. (8) No major aircraft repair or maintenance operations shall be permitted on the roof, except in cases of emergency and with the approval of the executive director of the airport authority. (9) Communication facilities shall be provided from the roof area to allow notification of the fire department and building personnel in the event of emergency. (10) Heliport personnel shall be properly trained in the use of communication facilities and fire extinguishing equipment. (11) Lighting shall be provided as required by the executive director of the airport authority. (12) Rooftop heliports shall be divided into three classes, as follows, according to the gross weight of the largest helicopter to be accommodated: Class I. Up to 6,000 pounds. Class II. Six thousand pounds to 12,500 pounds. Class III. Twelve thousand five hundred pounds to 20,000 pounds. (13) Egress and fire extinguishing facilities shall be provided according to the class of heliport, as follows: Class I a. At least one exit from the rooftop shall be provided, such exit to be in accordance with the building code of the city. b. At least one 150-pound dry chemical extinguisher shall be provided. c. At least two 15-pound portable dry chemical extinguishers shall be located on the rooftop and in proximity to the exit. At least one extinguisher shall be manned during operations. Class II d. At least one exit from the rooftop shall be provided, such exit to be in accordance with the city building code. e. At least two 150-pound dry chemical extinguishers shall be provided. f. At least two 25-pound dry chemical portable extinguishers shall be provided on the rooftop and in proximity to the exit. At least one extinguisher shall be manned during operations. Class III g. At least two approved means of egress, remote from each other shall be provided from each landing area and rooftop. The exit from the roof shall lead into the building stairway. In the case of a built-up landing platform, one stairway from the landing area may be an approved portable emergency escape stairway which could be readily relocated to provide access to the landing area in an emergency. Exits shall be marked as provided for in the city building code. h. At least two hose stations, remote from each other, and connected to the rooftop outlets of the building standpipes or other source of water supply, shall be provided. Hose shall be 1½ inches in size, and provided with appropriate nozzles and related equipment for dispensing mechanical foam to protect all portions of the roof. i. Building standpipe systems or other source of water supply, such as pressure tanks, shall be capable of supplying two hose streams simultaneously, which will afford foam application at a total water rate of at least 60 gallons per minute, at a nozzle pressure of at least 75 pounds per square inch for a period of at least ten minutes. j. Supplementary extinguishing equipment, consisting of at least two 150-pound units of dry chemical or four 100-pound units of carbon dioxide shall be provided. k. At least two 25-pound portable, dry chemical extinguishers shall be provided on the rooftop and in proximity to the exits. At least one extinguisher shall be manned during landing and takeoff operations.

(Code 1971, § 8-18)

Ask a question about Jackson law

Corpus searches the Jackson sections it holds and shows the ones that match, with their citations. Free, no sign-in.