§ 20-48 — Building Sewers and Connections
Code of Ordinances, City of Laurel, Mississippi (complete code PDF dated 11-19-2026) · Laurel Code § 20-48
Corpus is an independent public-information project, not the official City of Laurel website. Stable reference: corpuslaw.us/code/cf020c9f-582c-4761-a8c3-9fb8e4d084b7
Section 20-48. Building Sewers and Connections.
(1) No unauthorized person shall uncover, make any connections with or open into, use, alter, or disturb any public sewer or appurtenance thereof without first obtaining a written permit from the Superintendent. (2) There shall be two (2) classes of building sewer permits: (a) for residential and commercial service; and (b) for service to establishments producing industrial wastes. In either case, the owner or his agent shall make application on a special form furnished by the City. The permit application shall be supplemented by any plans, specifications or other information considered pertinent in the judgment of the Superintendent. A permit and inspection fee of Two Hundred Dollars ($200.00) for a residential and commercial building sewer permit and Five Hundred Dollars ($500.) for an industrial building sewer permit shall be paid to the City at the time the application is filed. As a condition for authorization to dispose of industrial wastes through the municipal system, the industrial applicant for a sewer permit shall provide the City with information describing wastewater constituents and characteristics, and the type of activity and quantity of production. (3) All costs and expense incidental to the installation and connection of the building sewer shall be borne by the owner. The owner shall indemnify the City from any loss or damage that may directly or indirectly be occasioned by the installation of the building sewer. (4) A separate and independent building sewer shall be provided for every building except where one (1) building stands at the rear of another on an interior lot and no private sewer is available or can be constructed to the rear building through an adjoining alley, court, yard or driveway, the building sewer from the front building may be extended to the rear building and the whole considered as one (1) building sewer. (5) Old building sewers may be used in connection with new buildings only when they are found, on examination and test by the Superintendent, to most all requirements of this Ordinance. (6) The size, slope, alignment, materials of construction of a building sewer and the methods to be used in excavating, placing of the pipe, jointing, testing and backfilling the trench, shall conform to the requirements of the Building and Plumbing Code or other applicable rules and regulations of the City. In the absence of Code provisions or, in amplification thereof, the materials and procedures set forth in appropriate specifications of the American Society for Testing and Materials (ASTM) and the Water Pollution Control Federation (WPCF) Manual of Practice No. 9 shall apply. (7) Whenever possible, the building sewer shall be brought to the building at an elevation below the basement floor. In all buildings in which any building drain is too low to permit gravity flow to the public sewer, sanitary sewage carried by such building drain shall be lifted by an approved means and discharged to the building sewer. (8) No person shall make connection of roof downspouts, exterior foundation drains, areaway drains, or other sources of surface run-off or, groundwater to a building sewer or building drain which in turn is connected directly or indirectly to a public sanitary sewer. (9) The connection of the building sewer into the public sewer shall conform to the requirements of the Building and Plumbing Code or other applicable rules and regulations of the City or the procedures set forth in appropriate specifications of the ASTM and the WPCF Manual of Practice No. 9. All such connections shall be made gastight and watertight. Any deviation from the prescribed procedures and materials shall be approved by the Superintendent before installation. The Superintendent shall prescribe saddles or other connections that will not allow protrusion into the public sewer and will meet the gastight and watertight requirements. The connection shall be made under the supervision of the City and prior to backfilling, a Polaroid picture shall be taken by a designated City employee. On the back of said photo, there shall be entered the date, appropriate street address, distance in feet between the center line of the connection and the nearest manhole, the number of the manhole and the employee’s name. This photo shall be turned over to the Engineering Department and within ten (10) days thereof the connection entered on the master drawing of the sewer system. The photo is to be permanently filed. (10) The applicant for the building sewer permit shall notify the Superintendent when the building sewer is ready for inspection and connection to the public sewer. The connection shall be made under the supervision of the Superintendent or his representative. (11) All excavations for building sewer installation shall be adequately guarded with barricades and lights so as to protect the public from hazard. Streets, sidewalks, parkways and other public property disturbed in the course of the work shall be restored in a manner satisfactory to the City.
Source: Ordinance No. 1177-1990, § 21-103, 12-28-90
Ask a question about Laurel law
Corpus searches the Laurel sections it holds and shows the ones that match, with their citations. Free, no sign-in.
