§ 26-3 — Responsibility of Water System
Code of Ordinances, City of Laurel, Mississippi (complete code PDF dated 11-19-2026) · Laurel Code § 26-3
Corpus is an independent public-information project, not the official City of Laurel website. Stable reference: corpuslaw.us/code/ae7433ca-0a52-4149-b437-4951282aa4ea
Section 26-3. Responsibility of Water System.
1. Surveys. The City of Laurel shall develop and implement a cross connection control program and shall conduct a survey with on-site visits as necessary to locate potential cross connections within its system, before December 31, 2000. 2. Right to Entry. Each customer identified during the survey as having a potentially high-hazard cross connection shall install an approved backflow preventer within ninety (90) days of receiving such notice. Additional time may be granted for hardship, however, all high-hazard backflow devices must be installed before June 30, 2001. 3. Classification of Hazard. Each cross connection will be classified as High Hazard or Low Hazard. The City of Laurel will follow the recommendations of the Mississippi Department of Health in defining a high hazard connection or a low hazard connection. Of the low hazard connections, those posing a very low risk shall be exempt from the requirements to have a backflow prevention device. (A) For the purpose of this section, the following cross connections shall be considered low hazard cross connections posing a very low risk and therefore shall not be required to have a backflow prevention device: (1) Any lawn sprinkler or lawn irrigation system that is connected to a public water system was professionally installed, regardless of whether the system is underground or above ground or whether the system has pop-up sprinkler heads; (2) Any swimming pool that is connected a public water system and was professionally installed, or any swimming pool that is connected to a public water system and has a fill line with an anti- siphon air gap; (3) Any water fountain or cooler that provides drinking water for human consumption, that is connected to a public water system and was professionally installed; (4) Any fire sprinkler system that contains only water or a dry pipe and no chemicals, that is connected to a public water system and was professionally installed; and (5) Any commercial establishment that is connected to a public water system, that contains no cross connections directly with a dangerous or hazardous substance or material. (B) For the purposes of this section, any lawn sprinkler system or lawn irrigation system that is connected to a public water system and either injects or stores lawn chemicals or is connected to a wastewater supply shall be considered as high hazard cross connections and not exempt from the requirements of this section; however, the local public water system shall not be required to conduct an on-site inspection to identify any such system under this paragraph. (C) Additional backflow preventer devices shall not be required for carbonated beverage dispensers if (i) the water supply connection to the carbonated beverage dispenser is protected against backflow by a backflow preventer device conforming to ASSE 1022 or by an air gap, (ii) the backflow preventer device and the piping downstream from the device are not affected by carbon dioxide gas. 4. Selecting the Appropriate Backflow Preventer. It shall be the responsibility of the City of Laurel, acting through its agent, to determine the type of backflow preventer required at each cross connection and the location the backflow preventer will be installed. The type backflow preventer required and the location to be installed, will be selected utilizing guidelines published by the Mississippi State Department of Health. 5. Schedule of Installation and Testing. (A) Before June 30, 2001, each property owner identified by the public water system as having a high hazard cross connection shall install a backflow preventer device. If the property owner already has a backflow preventer device installed and the backflow preventer device functions properly, the public water system shall consider the backflow preventer device approved and shall allow the installed backflow preventer device to remain in place until the backflow preventer device fails to function properly. (B) Before June 30, 2004, each property owner identified by the public water system as having a low hazard cross connection shall install a backflow preventer device. This requirement does not apply to any low hazard cross connection that poses a very low risk. If the property owner already has a backflow preventer device installed and the backflow preventer device functions property, the public water system shall consider the backflow preventer device approved and shall allow the installed backflow preventer device to remain in place until the backflow preventer device fails to function properly. (C) Each backflow preventer device shall be inspected and tested immediately after installation, after repairs of any kind, and at least annually. If a high hazard backflow preventer device fails to function properly, the property owner shall have the backflow preventer device repaired and retested or shall install a new approved backflow preventer device within thirty (30) days of the initial test. If a low hazard backflow preventer device fails to function properly, the property owner shall have the backflow preventer device repaired or shall install a new backflow preventer device within ninety (90) days after the date the backflow preventer device first fails to function properly. 6. Review of Meter Applications. The City of Laurel, acting through its agent, shall review all applications for new meters to determine if a cross connection will be created. The appropriate backflow preventer will be required at all new connections where a cross connection will be created. 7. Inspections. The City of Laurel, acting through its agent, will periodically inspect any connection to the water system as deemed necessary to insure cross connections have not been created. 8. Record Keeping. The City of Laurel shall maintain records of the type, size and location of each backflow preventer installed in the system, when each backflow preventer is due to be tested, and the result of each test. Records shall be maintained for five (5) years from date of test and inspection.
Source: Ordinance No. 1375-2000, 10-17-00 Source: Ordinance No. 1375-2000, 10-17-00 Source: Ordinance No. 1375-2000, 10-17-00 amended by Ordinance No. 1397-2002, 3.03, 1-8-02 Source: Ordinance No. 1397-2002, 3.05, 1-8-02 Source: Ordinance No. 1332-1999, §3, 2-16-99
Ask a question about Laurel law
Corpus searches the Laurel sections it holds and shows the ones that match, with their citations. Free, no sign-in.